Change history for APS - 31-ID

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2022-06-23 12:06:11 Beam Focal Spot Size at Sample (µm^2) 150x40 130x40
2022-06-23 12:05:28 Spot Size (mm): Width 0.150 0.130
2022-06-22 07:15:35 Backup Services 40 TB NAS, Avamar (daily backup), 208 TB Isilon (archive) 40 TB NAS, Avamar (daily backup), 208 TB Isilon (archive)
2022-06-22 07:15:09 Backup Services NAS, Avamar 40 TB NAS, Avamar (daily backup), 208 TB Isilon (archive)
2022-06-22 07:13:43 Software: Name XDS (autoPROC), MOSFLM, CCP4, DIALS, d*TREK autoPROC (XDS, aimless), MOSFLM, CCP4, DIALS, d*TREK
2022-06-22 07:12:41 Detector: Model DECTRIS PILATUS 6M PILATUS3 S 6M
2022-06-22 07:12:14 Spot Size (mm): Height 0.05 0.04
2022-06-22 07:11:40 Sample Handling: Manual available
2022-06-22 07:11:13 Goniometer Aerotech/Micronix/Keyence OAV, Aerotech air-bearing single rotation axis Aerotech/Micronix/Keyence OAV, Aerotech air-bearing single horizontal rotation axis
2022-06-22 07:11:02 Goniometer Aerotech/Micronix/Keyence OAV, single axis Aerotech/Micronix/Keyence OAV, Aerotech air-bearing single rotation axis
2022-06-22 07:08:48 Services Mail-in Mail-in
2022-06-22 07:08:38 Special Capabilities Details automated loop/X-ray centering, processing, data transfer automated loop/X-ray centering, processing, data transfer, unscheduled, 18-32 data turnaround
2022-06-22 07:08:11 Special Capabilities Details High-throughput screening and data collection (>10,000 crystals and >4,000 data sets per year) automated loop/X-ray centering, processing, data transfer
2022-06-22 07:06:15 Special Capabilities High Temperature High Throughput
2022-06-22 07:05:58 Special Capabilities Automatic Crystal Alignment, Automated Sample Screening, High Throughput High Temperature
2022-06-22 07:04:42 Sample Handling: Robotics (CATS) Cryogenic Auto Transfer System ISARA (IRELEC)
2022-06-22 07:04:32 Robotics: More Info 540 crystal capacity, SPINE mounts 464 LN2 samples, 96 RT samples crystal capacity, SPINE bases (Molec. Dim.), UniPucks, Hampton Research pins/nylon loops
2022-06-22 07:02:27 Flux Coefficient 5.2 5.6
2022-06-22 07:02:18 Spot Size (mm): Width 0.140 0.150
2022-06-22 07:01:53 Beam Focal Spot Size at Sample (µm^2) 150x40
2022-06-22 07:01:22 Backup Services sftp NAS, Avamar
2020-03-10 05:32:21 Flux Details At sample position: (Se K edge, 1st harmonic of undulator, 102 mA) measured with calibrated diode At sample position: (Se K edge, 1st harmonic of undulator, 102 mA current SR) measured with calibrated diode
2020-03-10 05:31:25 Software: Name SPEC, EPICS, Aerotech, Python, Oracle SPEC, EPICS, Aerotech, Python, Oracle, EPICS
2020-03-10 05:31:08 Wavelength (Å): Min .92 0.56
2020-03-10 05:30:46 Wavelength (Å): Max 1.38 2.47
2020-03-10 05:29:51 Energy Range (keV): Max 13.5 22
2020-03-10 05:29:47 Energy Range (keV): Min 9.0 5
2020-03-10 05:29:38 Flux Coefficient 2.6 5.2
2020-03-10 05:29:30 Crystal Type Diamond (111) Si (111)
2020-03-10 05:29:23 Monochromator Kohzu HLD-4 Double Crystal water cooled Kohzu HLD-15 Double Crystal cryocooled
2020-03-10 05:28:47 Spot Size (mm): Height 0.08 0.05
2020-03-10 05:28:39 Spot Size (mm): Width 0.120 0.140
2018-12-17 08:35:57 Services Details Automatic loop centering and screening/scoring, data collection, automatic data processing and data transfer, fast (24-32 h) crystal shipment to user receiving data turnaround Automatic loop centering and screening/scoring, data collection, automatic data processing and data transfer, very fast (24-32 h) crystal shipment to user receiving data turnaround
2018-12-17 08:34:46 Software: Name XDS (autoPROC), MOSFLM, CCP4, DIALS XDS (autoPROC), MOSFLM, CCP4, DIALS, d*TREK
2018-12-17 08:34:17 Hardware Venturi (crystal temperature stabilization) Venturi (crystal temperature stabilization), Norhof (sample ice removal)
2018-12-17 08:33:41 Hardware Venturi, Norhof Venturi (crystal temperature stabilization)
2018-12-17 08:31:33 Services Details Automatic loop centering and screening/scoring, data collection, automatic data processing and data transfer. Automatic loop centering and screening/scoring, data collection, automatic data processing and data transfer, fast (24-32 h) crystal shipment to user receiving data turnaround
2018-12-17 08:29:55 Special Capabilities High throughput Automatic Crystal Alignment, Automated Sample Screening, High Throughput
2018-12-17 08:27:55 Detector: Details Sample-to-detector distance: 190 - 1200 mm, 2 ms readout, 25 Hz max frame, 20 bit dynamic range rate Sample-to-detector distance: 190 - 1200 mm, 2 ms readout, 25 Hz max frame rate, 20 bit dynamic range
2018-12-17 08:26:56 Detector: Details Sample-to-detector distance: 190 - 1200 mm (0.04 s readout) Sample-to-detector distance: 190 - 1200 mm, 2 ms readout, 25 Hz max frame, 20 bit dynamic range rate
2018-10-12 03:31:39 Software: Name SPEC, EPICS, Aerotech, Python, MarCCD, Oracle SPEC, EPICS, Aerotech, Python, Oracle
2018-10-12 03:10:01 Detector: Details Sample-to-detector distance: 165 - 1200 mm (0.04 s readout) Sample-to-detector distance: 190 - 1200 mm (0.04 s readout)
2018-10-12 03:09:21 Detector: Removed from Service 2018-08-22
2018-02-19 09:54:33 Detector: Details Sample-to-detector distance: adjustable 85 - 600 mm Sample-to-detector distance: adjustable 85 - 600 mm (1.1 seconds readout, 1.7 seconds total deadtime)
2018-02-19 09:54:09 Software: Name SPEC, EPICS, Aerotech, Python, MarCCD SPEC, EPICS, Aerotech, Python, MarCCD, Oracle
2018-02-19 09:53:26 Beamline Website http://lrlcat.lilly.com/ https://www.aps.anl.gov/Beamlines/Directory/Details?beamline_id=45
2018-02-19 09:50:26 Mirrors Three coating stripes Rh, Pt, ULE Three coating stripes: Rh, Pt, ULE
2018-02-19 09:50:09 Optics Details KB mirrors fixed focus KB mirrors, fixed focus
2018-02-19 09:49:50 Optics Details KB mirrors KB mirrors fixed focus
2018-02-19 09:49:27 Services Details Automatic loop centering and screening/scoring, automatic crystal selection and data collection, and automatic data processing and transfer. Automatic loop centering and screening/scoring, data collection, automatic data processing and data transfer.
2018-02-19 09:48:46 Special Capabilities Details High-throughput data collection (>10,000 crystals and >4,000 data sets per year) High-throughput screening and data collection (>10,000 crystals and >4,000 data sets per year)
2018-02-19 09:48:35 Special Capabilities Details high-throughput data collection (>10,000 crystals and >4,000 data sets per year) High-throughput data collection (>10,000 crystals and >4,000 data sets per year)
2018-02-19 09:47:05 Backup Services sftp
2018-02-19 09:46:48 Lab Facilities NORMAL
2018-02-19 09:46:36 Cryo Capability Details 100 K
2018-02-19 09:46:27 Cryo Capability Oxford Cryosystems cryostream 700 Oxford Cryostream - 700 series
2018-02-19 09:46:07 Detector: Details sample-to-detector distance: adjustable 85 - 600 mm Sample-to-detector distance: adjustable 85 - 600 mm
2018-02-19 09:45:59 Detector: Details sample-to-detector distance: adjustable 85 - 1000 mm sample-to-detector distance: adjustable 85 - 600 mm
2018-02-19 09:45:51 Detector: Details sample-to-detector distance: adjustable 85 - 1000 mm
2018-02-19 09:44:27 Robotics: More Info 540 crystals, SPINE/EMBL bases & vials, nylon loops 540 crystal capacity, SPINE mounts
2018-02-19 09:43:28 Mirrors Plane-ellipsoidal, three coating stripes Rh, Pt, ULE Three coating stripes Rh, Pt, ULE
2018-02-19 09:43:17 Crystal Type Diamond (11) Diamond (111)
2018-02-19 09:43:14 Crystal Type Diamond 111 Diamond (11)
2018-02-19 09:42:56 Optics Details Pair of KB mirrors KB mirrors
2018-02-19 09:42:50 Optics Details Pair of KB mirrors
2018-02-19 09:41:44 Experiments MAD, SAD MAD, SAD, MONOCHROMATIC
2018-02-19 09:41:13 Source Details APS Undulator A 3.3 cm period
2018-02-19 09:40:06 Goniometer Aerotech/Micronix/Keyence Aerotech/Micronix/Keyence OAV, single axis
2018-02-19 09:39:32 Flux Details At sample position: (Se K edge, 1st harmonic of undulator, 102 mA) with calibrated diode At sample position: (Se K edge, 1st harmonic of undulator, 102 mA) measured with calibrated diode
2018-02-19 09:39:15 Mirrors three coating stripes Rh, Pt, ULE Plane-ellipsoidal, three coating stripes Rh, Pt, ULE
2018-02-19 09:38:57 Mirrors KB Rh, Pt, ULE three coating stripes Rh, Pt, ULE
2018-02-19 09:38:37 Monochromator Kohzu HLD-4 Double Crystal Kohzu HLD-4 Double Crystal water cooled
2018-02-19 09:38:14 Flux Details At sample position: (Se K edge, 1st harmonic of undulator) with calibrated detector At sample position: (Se K edge, 1st harmonic of undulator, 102 mA) with calibrated diode
2018-02-19 09:35:11 Software: Classification Processing Modeling/graphics
2018-02-19 09:35:07 Software: Name XDS (autoPROC), MOSFLM, CCP4 COOT
2018-02-19 09:34:57 Software: Classification Modeling/graphics Phasing/refinement
2018-02-19 09:34:50 Software: Name COOT SHELX, CCP4
2018-02-19 09:34:31 Software: Classification Control/collection Processing
2018-02-19 09:34:27 Software: Classification Control/collection Processing
2018-02-19 09:34:22 Software: Classification Control/collection Modeling/graphics
2018-02-19 09:31:37 Monochromator HLD-4 Double Crystal Kohzu HLD-4 Double Crystal
2018-02-19 09:30:55 Hardware Venturi, Norhof
2018-02-19 09:26:59 Robotics: More Info 540 crystals, SPINE/EMBL bases & vials 540 crystals, SPINE/EMBL bases & vials, nylon loops
2018-02-19 09:26:42 Robotics: More Info 540 crystals, MAR/SPINE mount 540 crystals, SPINE/EMBL bases & vials
2018-02-19 09:26:19 Goniometer Aerotech/Micronix Aerotech/Micronix/Keyence
2018-02-19 09:26:04 Energy Range (keV): Min 9 9.0
2018-02-19 09:25:53 Wavelength (Å): Max 1.4 1.38
2018-02-19 09:25:20 Wavelength (Å): Min .9 .92
2018-02-19 09:24:40 Energy Range (keV): Max 28 Beamline: 9.0 - 13.8 keV (1.4 - 0.90 A 13.5
2018-02-19 09:24:28 Wavelength (Å): Min .5 .9
2018-02-19 09:24:24 Wavelength (Å): Max 2.4 1.4
2018-02-19 09:24:06 Energy Range (keV): Min 4.7 9
2018-02-19 09:22:50 Source Type insertion device INSERTION DEVICE
2018-02-19 09:22:45 Services Details This beamline is dedicated to mail-in data collection with automatic evaluation of crystal quality, automatic centering based on loops, and automatic data transfer Automatic loop centering and screening/scoring, automatic crystal selection and data collection, and automatic data processing and transfer.
2018-02-19 09:20:28 Services Details This beamline is dedicated to mail-in data collection with automatic evaluation of crystal quality, automatic centering based on loops, and automatic removal of surface ice This beamline is dedicated to mail-in data collection with automatic evaluation of crystal quality, automatic centering based on loops, and automatic data transfer
2018-02-19 09:19:47 Status operational Operational
2018-02-19 09:19:35 Software: Name CCP4/COOT COOT
2018-02-19 09:19:28 Software: Name XDS (autoPROC), MOSFLM, CCP4 XDS (autoPROC), MOSFLM, CCP4, DIALS
2018-02-19 09:19:14 Software: Name SPEC, EPICS, Aerotech, Python SPEC, EPICS, Aerotech, Python, MarCCD
2018-02-19 09:19:00 Software: Name XDS (autoPROC), MOSFLM, CCP4 SPEC, EPICS, Aerotech, Python
2018-02-19 09:18:29 Software: Classification Control/collection Control/collection
2018-02-19 09:17:54 Software: Name XDS (autoPROC), MOSFLM XDS (autoPROC), MOSFLM, CCP4
2018-02-19 09:17:18 Software: Name Beamline control: spec (Certified Scientific Systems), MARCCD SPEC
2018-02-19 09:17:07 Software: Classification Control/collection
2018-02-19 09:15:43 Detector: Model RAYONIX MX-225 HE MAR 165 mm
2018-02-19 09:15:24 Detector: Model MAR 165mm RAYONIX MX-225 HE
2018-02-19 09:15:08 Robotics: More Info 540 crystals, MAR/SPINE mount, manual and loop centroid centering 540 crystals, MAR/SPINE mount
2018-02-19 09:14:49 Sample Handling: Robotics (CATS) Cryogenic Auto Transfer System (CATS) Cryogenic Auto Transfer System
2018-02-19 09:14:36 Goniometer MAR dtb Aerotech/Micronix
2018-02-19 09:14:19 Flux Details At sample position: (Se K edge, 1st harmonic of undulator) ~2 - measured w/Si pin diode At sample position: (Se K edge, 1st harmonic of undulator) with calibrated detector
2018-02-19 09:13:11 Flux Coefficient 2 2.6
2018-02-19 09:13:04 Flux Coefficient 2 2
2018-02-19 09:12:41 Optics Details KB
2018-02-19 09:12:20 Monochromator Diamond(111) HLD-4 Double Crystal
2018-02-19 09:11:52 Optics Details KB
2018-02-19 09:11:48 Monochromator Diamond(111)
2018-02-19 09:11:41 Spot Size (mm): Width 0.07 0.120
2018-02-19 09:11:32 Spot Size (mm): Height 0.07 0.08
2018-02-19 09:09:31 Experiments SAD MAD, SAD
2018-02-19 09:09:20 Experiments MAD, SAD, FIBER SAD
2018-02-19 09:08:58 Beamline Website http://www.aps.anl.gov/Beamlines/Directory/beamline.php?beamline_id=45 http://lrlcat.lilly.com/
2018-02-19 09:08:37 Secondary Contact: Email jkoss@lilly.com morisco_laura@lilly.com
2018-02-19 09:08:19 Primary Contact: Email swasserman@lilly.com benach_jordi@lilly.com
2018-02-19 09:08:06 Primary Contact: Name Stephen Waserman Jordi Benach
2011-06-14 11:03:41 Robotics: More Info 19 crystals, MAR/SPINE mount, manual and loop centroid centering - Mar carousel changer (6 carousels, 114 crystals, 3.5 minutes change time) 540 crystals, MAR/SPINE mount, manual and loop centroid centering
2011-06-14 11:03:06 Sample Handling: Robotics (CSC) MAR Cryogenic (CATS) Cryogenic Auto Transfer System
2011-05-19 08:57:04 Beamline Website http://www.aps.anl.gov/Beamlines/Directory/beamline.php?beamline_id=45
2009-07-29 11:30:34 Owner/Operator LRL-CAT LRL-CAT, Eli Lilly & Company
2009-07-29 11:30:20 Owner/Operator LRL-CAT LRL-CAT
2009-07-29 11:29:50 Secondary Contact: Name John Koss Laura Morisco
2009-07-29 11:29:38 Primary Contact: Email laura_morisco@lilly.com swasserman@lilly.com
2009-07-29 11:29:27 Primary Contact: Name Laura Morisco Stephen Waserman