Change history for ESRF - ID29

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2023-06-19 12:38:45 Detector: Activated for Service 2010-07-01 2022-07-01
2023-06-19 12:34:51 Cryo Capability Oxford cryosystems 700 series NONE
2023-06-19 12:34:34 Robotics: More Info The Sample Changer has been designed for use with SPINE standard sample holders and vials, which are loaded into the SC in baskets specifically designed for the SCs. The goniometer head that must be used in conjunction with the SCs is equipped with a SmartMagnet. This detects whether a sample is mounted on the goniometer head or not. Each indivudual SmartMagnet is tuned for operation on a particular beam-line and a goniometer head must NOT be taken from one beam-line for use on another. New fixed target automounter under development
2023-06-19 12:33:48 Goniometer Details Minikappa goniometer - beam is conditioned by 5 different beam defining apertures - 10 20 30 50 75 um Newly developed MD3up with SSX fast translating stage
2023-06-19 12:33:25 Goniometer MD2 Microdiffractometer MD3upSSX
2023-06-19 12:33:14 Energy Range (keV): Min 6 10
2023-06-19 12:33:08 Wavelength (Å): Max 2.1 1.24
2023-06-19 12:21:03 Mirrors cylindrical grazing incidence mirror bent to approximate to a toroidal curvature Elliptically shaped KB mirrors
2023-06-19 12:14:52 Flux Details in 1% bandwidth
2023-06-19 12:14:45 Flux Exponent 13 15
2023-06-19 12:14:00 Crystal Type Si(111) and Si (311) Three different coatings
2023-06-19 12:13:47 Optics Details Due to geometry of the channel-cut crystal, the Si(311) monochromator can only be used at energies higher than 9.6 keV. 1% and 0.4% bandwidth
2023-06-19 12:13:26 Monochromator liquid nitrogen cooled channel-cut silicon monochromator Horizontally deflecting double multilayer mirrors
2023-06-19 12:12:53 Spot Size (mm): Width 0.05 0.004
2023-06-19 12:12:48 Spot Size (mm): Height 0.03 0.002
2023-06-19 12:12:41 Source Details two complementary undulator sources - a standard U35 and an in vacuum U21 two complementary undulator sources - an in vacuum U21 and a CPMU16
2023-06-19 12:12:24 Special Capabilities Details ID29 is intended for high intensity, high energy resolution MAD and SAD measurements over a wide range of X-ray wavelengths. ID29 is the new beamline dedicated to Time Resolved Serial Macromolecular Crystallography
2023-06-19 12:12:01 Special Capabilities Absorption Edges, High Intensity Serial Crystallography
2023-06-19 12:11:49 Experiments Details Time Resolved Serial Crystallography
2023-06-19 12:11:04 Beamline Website http://www.esrf.fr/UsersAndScience/Experiments/MX/About_our_beamlines/ID29 http://www.esrf.fr/id29
2023-06-19 12:10:58 Secondary Contact: Email sbasu@esrf.fr
2023-06-19 12:10:51 Secondary Contact: Name Gordon Leonard Shibom Basu
2014-03-13 06:51:29 Detector: Model DECTRIS PILATUS 6M DECTRIS PILATUS 6M
2014-03-13 06:51:12 Flux Coefficient 2 1
2014-03-13 06:50:55 Spot Size (mm): Width 0.06 0.05
2014-03-13 06:50:51 Spot Size (mm): Height 0.05 0.03
2011-10-25 05:42:53 Hardware http://www.esrf.fr/UsersAndScience/Experiments/MX/How_to_use_our_beamlines/Run_Your_Experiment/Computing_Environment http://www.esrf.eu/UsersAndScience/Experiments/MX/About_our_beamlines/ID29
2011-10-25 05:41:06 Goniometer Details Minikappa goniometer Minikappa goniometer - beam is conditioned by 5 different beam defining apertures - 10 20 30 50 75 um
2011-10-25 05:40:08 Goniometer Details Minikappa available Minikappa goniometer
2011-10-25 05:40:00 Goniometer Details Minikappa available
2011-10-25 05:39:43 Flux Exponent 13
2011-10-25 05:39:40 Flux Coefficient 2
2011-10-25 05:39:06 Wavelength (Å): Min 0.7 0.62
2011-10-25 05:38:16 Backup Services DLT tape drive External disk USB2.0 USB3.0
2011-10-25 05:37:38 Detector: Details Shutterless data collection
2011-10-25 05:36:48 Goniometer microdiffractometer MD2 Microdiffractometer
2011-10-25 05:36:34 Energy Range (keV): Max 17.7 20
2011-10-25 05:36:28 Energy Range (keV): Min 6
2011-10-25 05:36:05 Source Type insertion device INSERTION DEVICE
2011-10-25 05:35:55 Special Capabilities Details D29 is intended for high intensity, high energy resolution MAD and SAD measurements over a wide range of X-ray wavelengths. ID29 is intended for high intensity, high energy resolution MAD and SAD measurements over a wide range of X-ray wavelengths.
2011-10-25 05:34:46 Owner/Operator Macromolecular Crystallography Group ESRF Strctural Biology Group
2011-10-25 05:34:30 Primary Contact: Email muellerd@esrf.fr daniele.de_sanctis@esrf.fr
2011-10-25 05:34:17 Primary Contact: Name Christoph Mueller-Dieckmann Daniele de Sanctis
2009-12-21 05:45:12 Primary Contact: Name Christopher Mueller-Dieckmann Christoph Mueller-Dieckmann
2009-12-01 09:40:38 Detector: Model Rontec Silicon drift ADSC Quantum 315r