2023-06-19 12:38:45 |
Detector: Activated for Service |
2010-07-01 |
2022-07-01 |
2023-06-19 12:34:51 |
Cryo Capability |
Oxford cryosystems 700 series |
NONE |
2023-06-19 12:34:34 |
Robotics: More Info |
The Sample Changer has been designed for use with SPINE standard sample holders and vials, which are loaded into the SC in baskets specifically designed for the SCs. The goniometer head that must be used in conjunction with the SCs is equipped with a SmartMagnet. This detects whether a sample is mounted on the goniometer head or not. Each indivudual SmartMagnet is tuned for operation on a particular beam-line and a goniometer head must NOT be taken from one beam-line for use on another. |
New fixed target automounter under development |
2023-06-19 12:33:48 |
Goniometer Details |
Minikappa goniometer - beam is conditioned by 5 different beam defining apertures - 10 20 30 50 75 um |
Newly developed MD3up with SSX fast translating stage |
2023-06-19 12:33:25 |
Goniometer |
MD2 Microdiffractometer |
MD3upSSX |
2023-06-19 12:33:14 |
Energy Range (keV): Min |
6 |
10 |
2023-06-19 12:33:08 |
Wavelength (Å): Max |
2.1 |
1.24 |
2023-06-19 12:21:03 |
Mirrors |
cylindrical grazing incidence mirror bent to approximate to a toroidal curvature |
Elliptically shaped KB mirrors |
2023-06-19 12:14:52 |
Flux Details |
|
in 1% bandwidth |
2023-06-19 12:14:45 |
Flux Exponent |
13 |
15 |
2023-06-19 12:14:00 |
Crystal Type |
Si(111) and Si (311) |
Three different coatings |
2023-06-19 12:13:47 |
Optics Details |
Due to geometry of the channel-cut crystal, the Si(311) monochromator can only be used at energies higher than 9.6 keV. |
1% and 0.4% bandwidth |
2023-06-19 12:13:26 |
Monochromator |
liquid nitrogen cooled channel-cut silicon monochromator |
Horizontally deflecting double multilayer mirrors |
2023-06-19 12:12:53 |
Spot Size (mm): Width |
0.05 |
0.004 |
2023-06-19 12:12:48 |
Spot Size (mm): Height |
0.03 |
0.002 |
2023-06-19 12:12:41 |
Source Details |
two complementary undulator sources - a standard U35 and an in vacuum U21 |
two complementary undulator sources - an in vacuum U21 and a CPMU16 |
2023-06-19 12:12:24 |
Special Capabilities Details |
ID29 is intended for high intensity, high energy resolution MAD and SAD measurements over a wide range of X-ray wavelengths. |
ID29 is the new beamline dedicated to Time Resolved Serial Macromolecular Crystallography |
2023-06-19 12:12:01 |
Special Capabilities |
Absorption Edges, High Intensity |
Serial Crystallography |
2023-06-19 12:11:49 |
Experiments Details |
|
Time Resolved Serial Crystallography |
2023-06-19 12:11:04 |
Beamline Website |
http://www.esrf.fr/UsersAndScience/Experiments/MX/About_our_beamlines/ID29 |
http://www.esrf.fr/id29 |
2023-06-19 12:10:58 |
Secondary Contact: Email |
|
sbasu@esrf.fr |
2023-06-19 12:10:51 |
Secondary Contact: Name |
Gordon Leonard |
Shibom Basu |
2014-03-13 06:51:29 |
Detector: Model |
DECTRIS PILATUS 6M |
DECTRIS PILATUS 6M |
2014-03-13 06:51:12 |
Flux Coefficient |
2 |
1 |
2014-03-13 06:50:55 |
Spot Size (mm): Width |
0.06 |
0.05 |
2014-03-13 06:50:51 |
Spot Size (mm): Height |
0.05 |
0.03 |
2011-10-25 05:42:53 |
Hardware |
http://www.esrf.fr/UsersAndScience/Experiments/MX/How_to_use_our_beamlines/Run_Your_Experiment/Computing_Environment |
http://www.esrf.eu/UsersAndScience/Experiments/MX/About_our_beamlines/ID29 |
2011-10-25 05:41:06 |
Goniometer Details |
Minikappa goniometer |
Minikappa goniometer - beam is conditioned by 5 different beam defining apertures - 10 20 30 50 75 um |
2011-10-25 05:40:08 |
Goniometer Details |
Minikappa available |
Minikappa goniometer |
2011-10-25 05:40:00 |
Goniometer Details |
|
Minikappa available |
2011-10-25 05:39:43 |
Flux Exponent |
|
13 |
2011-10-25 05:39:40 |
Flux Coefficient |
|
2 |
2011-10-25 05:39:06 |
Wavelength (Å): Min |
0.7 |
0.62 |
2011-10-25 05:38:16 |
Backup Services |
DLT tape drive |
External disk USB2.0 USB3.0 |
2011-10-25 05:37:38 |
Detector: Details |
|
Shutterless data collection |
2011-10-25 05:36:48 |
Goniometer |
microdiffractometer |
MD2 Microdiffractometer |
2011-10-25 05:36:34 |
Energy Range (keV): Max |
17.7 |
20 |
2011-10-25 05:36:28 |
Energy Range (keV): Min |
|
6 |
2011-10-25 05:36:05 |
Source Type |
insertion device |
INSERTION DEVICE |
2011-10-25 05:35:55 |
Special Capabilities Details |
D29 is intended for high intensity, high energy resolution MAD and SAD measurements over a wide range of X-ray wavelengths. |
ID29 is intended for high intensity, high energy resolution MAD and SAD measurements over a wide range of X-ray wavelengths. |
2011-10-25 05:34:46 |
Owner/Operator |
Macromolecular Crystallography Group |
ESRF Strctural Biology Group |
2011-10-25 05:34:30 |
Primary Contact: Email |
muellerd@esrf.fr |
daniele.de_sanctis@esrf.fr |
2011-10-25 05:34:17 |
Primary Contact: Name |
Christoph Mueller-Dieckmann |
Daniele de Sanctis |
2009-12-21 05:45:12 |
Primary Contact: Name |
Christopher Mueller-Dieckmann |
Christoph Mueller-Dieckmann |
2009-12-01 09:40:38 |
Detector: Model |
Rontec Silicon drift |
ADSC Quantum 315r |