2021-02-08 10:03:22 |
Secondary Contact: Email |
|
fgil@cells.es |
2021-02-08 10:03:15 |
Secondary Contact: Name |
|
Fernando Gil |
2021-02-08 10:03:05 |
Primary Contact: Email |
juanhuix@cells.es |
rboer@cells.es |
2021-02-08 10:02:57 |
Primary Contact: Name |
Jordi Juanhuix |
Roeland Boer |
2014-02-20 07:06:54 |
Flux Details |
At 10 keV, sample position, 250mA (Measured with calibrated diode) |
At 12,658 keV, sample position, 250mA (Measured with calibrated diode) |
2014-02-20 07:06:32 |
Hardware |
XDS, iMosflm, AutoPROC, and all common MX software available |
|
2014-02-20 07:06:19 |
Hardware |
|
XDS, iMosflm, AutoPROC, and all common MX software available |
2014-02-20 07:05:39 |
Backup Services |
sftp, external hard disks |
sftp, vpn, external hard disks |
2014-02-20 07:05:24 |
Cryo Capability Details |
|
100 K |
2014-02-20 07:04:52 |
Detector: Details |
sample-detector distance: adjustable 100-1356mm |
sample-detector distance: adjustable 123-1356mm |
2014-02-20 07:04:19 |
Spot Size (mm): Height |
0.01 - 0.1 |
0.006 - 0.2 |
2014-02-20 07:03:46 |
Secondary Contact: Email |
jbenach@cells.es |
|
2014-02-20 07:03:41 |
Secondary Contact: Name |
Jordi Benach |
|
2012-12-14 09:00:23 |
Status Details |
Next proposal submission period ~Oct 2012 |
Next proposal submission period Mid 2013 |
2012-08-27 01:17:58 |
Sample Handling: Manual |
Available |
Available for magnetic mounts, SPINE standard preferred |
2012-08-27 01:13:13 |
Flux Details |
At 10 (Se K-edge), sample position, 250mA (Measured with calibrated diode) |
At 10 keV, sample position, 250mA (Measured with calibrated diode) |
2012-08-27 01:10:31 |
Detector: Activated for Service |
info currently not available |
2011-06-22 |
2012-08-27 01:10:08 |
Detector: Details |
|
sample-detector distance: adjustable 100-1356mm |
2012-08-27 01:09:20 |
Robotics: More Info |
SPINE pins and cassettes only. Pins preferably from Molecular Dimensions. PLATES: robot can perform automatic screening of plates (Greiner, MRC 2 wells) |
SPINE pins and cassettes only. Pins preferably from Molecular Dimensions. PLATES: robot can perform automatic screening of plates (Greiner, MRC 2 wells) |
2012-08-27 01:08:46 |
Wavelength (Å): Max |
2.1 |
2.5 |
2012-08-27 01:08:30 |
Energy Range (keV): Min |
6 |
5 |
2012-08-27 01:08:00 |
Energy Range (keV): Max |
20 |
22 |
2012-08-27 01:07:50 |
Wavelength (Å): Min |
0.6 |
0.56 |
2012-08-27 01:07:01 |
Flux Details |
At 12.658 keV (Se K-edge), sample position, 250mA (CALCULATED) |
At 10 (Se K-edge), sample position, 250mA (Measured with calibrated diode) |
2012-08-27 01:06:37 |
Flux Coefficient |
>2 |
2 |
2012-08-27 01:05:30 |
Spot Size (mm): Height |
0.01 - 0.1 |
0.01 - 0.1 |
2012-08-27 01:05:13 |
Source Details |
In-vacuum undulator, 21.8 mm period, 2-meter long |
In-vacuum undulator, 21.6 mm period, 2-meter long |
2012-08-27 01:04:51 |
Services |
|
High quality data collection |
2012-08-27 01:03:49 |
Status Details |
Optics installed, end-station to start installation March 2010 |
Next proposal submission period ~Oct 2012 |
2012-08-27 01:01:21 |
Status |
Commissioning |
Operational |
2012-08-27 01:01:05 |
Secondary Contact: Email |
|
jbenach@cells.es |
2012-08-27 01:00:57 |
Secondary Contact: Name |
|
Jordi Benach |
2011-10-11 12:40:07 |
Status |
Under construction |
Commissioning |
2011-10-11 12:39:46 |
Backup Services |
|
sftp, external hard disks |
2011-10-11 12:39:17 |
Lab Facilities |
NORMAL |
COLD ROOM |
2011-10-11 12:38:14 |
Robotics: More Info |
SPINE pins and cassettes only. Pins preferably from Molecular Dimensions |
SPINE pins and cassettes only. Pins preferably from Molecular Dimensions. PLATES: robot can perform automatic screening of plates (Greiner, MRC 2 wells) |
2010-02-03 11:30:56 |
Monochromator |
Channel-cut (CINEL), cryocooled, 6mm gap |
Channel-cut double crystal monochromator (CINEL), cryocooled, 6mm gap |
2010-02-03 11:18:10 |
Flux Details |
At sample position, calculated |
At 12.658 keV (Se K-edge), sample position, 250mA (CALCULATED) |
2010-02-03 11:11:52 |
Mirrors |
Plane-ellipsiodal, three coating stripes (Si, Rh, Ir) - IRELEC/InSync |
Plane-ellipsoidal, three coating stripes (Si, Rh, Ir) - IRELEC/InSync |
2010-02-03 11:04:05 |
Mirrors |
Plane-ellipsiodal, three coating stripes (Si, Rh, Ir) |
Plane-ellipsiodal, three coating stripes (Si, Rh, Ir) - IRELEC/InSync |
2010-02-03 11:03:31 |
Monochromator |
channel-cut (CINEL) |
Channel-cut (CINEL), cryocooled, 6mm gap |
2010-02-03 11:03:05 |
Spot Size (mm): Width |
0.05-0.2 |
0.05 - 0.2 |
2010-02-03 11:03:00 |
Spot Size (mm): Height |
0.01-0.1 |
0.01 - 0.1 |
2010-02-03 11:02:54 |
Flux Details |
>2 10^12 ph/s at sample (calculated) |
At sample position, calculated |
2010-02-03 11:02:10 |
Flux Coefficient |
|
>2 |
2010-02-03 11:02:07 |
Flux Exponent |
|
12 |
2010-02-03 11:00:49 |
Robotics: More Info |
SPINE pins, preferably from Molecular Dimensions |
SPINE pins and cassettes only. Pins preferably from Molecular Dimensions |
2010-02-03 10:59:35 |
Wavelength (Å): Min |
|
0.6 |
2010-02-03 10:59:08 |
Wavelength (Å): Max |
|
2.1 |
2010-02-03 10:57:11 |
Source Details |
|
In-vacuum undulator, 21.8 mm period, 2-meter long |
2010-02-03 10:56:35 |
Source Type |
|
INSERTION DEVICE |
2010-02-03 10:56:20 |
Lab Facilities |
|
NORMAL |
2010-02-03 10:55:53 |
Sample Handling: Manual |
|
Available |
2010-02-03 10:55:14 |
Mirrors |
|
Plane-ellipsiodal, three coating stripes (Si, Rh, Ir) |
2010-02-03 10:54:22 |
Experiments |
MAD |
MAD, SAD, MONOCHROMATIC |
2010-02-03 08:20:27 |
Energy Range (keV): Min |
|
6 |
2010-02-03 08:20:21 |
Energy Range (keV): Max |
|
20 |
2010-02-03 05:49:32 |
Energy Range (keV): Min |
|
6 |
2010-02-03 05:48:53 |
Energy Range (keV): Min |
|
5 |
2010-02-03 05:48:14 |
Energy Range (keV): Min |
|
6 |
2010-02-03 05:47:50 |
Energy Range (keV): Min |
|
5 |
2010-02-03 05:47:47 |
Energy Range (keV): Max |
|
20 |
2010-02-02 11:45:18 |
Optics Details |
|
Pair of KB mirrors for adjustable focusing. Unfocused beam available too |
2010-02-02 11:44:00 |
Flux Details |
|
>2 10^12 ph/s at sample (calculated) |
2010-02-02 11:43:14 |
Special Capabilities |
Adjustable Focus Mirrors, Automatic Crystal Alignment |
Absorption Edges, Adjustable Focus Mirrors, Automated Sample Screening, High Resolution |
2010-02-02 11:42:49 |
Special Capabilities |
|
Adjustable Focus Mirrors, Automatic Crystal Alignment |
2010-02-02 11:42:33 |
Experiments |
|
MAD |
2010-02-02 11:42:20 |
Status Details |
|
Optics installed, end-station to start installation March 2010 |
2010-02-02 11:41:05 |
Status |
Under construction |
Under construction |
2010-02-02 11:40:32 |
Cryo Capability |
|
Oxford Cryostream - 700 series |
2010-02-02 11:40:17 |
Robotics: More Info |
|
SPINE pins, preferably from Molecular Dimensions |
2010-02-02 11:39:56 |
Sample Handling: Robotics |
|
(CATS) Cryogenic Auto Transfer System |
2010-02-02 11:39:48 |
Goniometer Details |
|
Mini-kappa available |
2010-02-02 11:39:26 |
Goniometer |
|
MD2M, single axis |
2010-02-02 11:38:47 |
Energy Range (keV): Max |
|
20 |
2010-02-02 11:38:42 |
Energy Range (keV): Min |
|
6 |
2010-02-02 11:38:30 |
Monochromator |
Si(111) channel-cut (CINEL) |
channel-cut (CINEL) |
2010-02-02 11:38:05 |
Crystal Type |
|
Si(111) |
2010-02-02 11:37:56 |
Spot Size (mm): Width |
|
0.05-0.2 |
2010-02-02 11:37:43 |
Spot Size (mm): Height |
0.05-0.2 |
0.01-0.1 |
2010-02-02 11:37:19 |
Spot Size (mm): Height |
|
0.05-0.2 |
2010-02-02 11:36:42 |
Monochromator |
|
Si(111) channel-cut (CINEL) |