2014-09-30 06:23:55 |
Cryo Capability Details |
|
20-200 K |
2014-09-30 06:23:46 |
Cryo Capability |
|
Cryo Industries Cryocool-LHe |
2014-09-30 06:23:23 |
Cryo Capability Details |
|
20-200 K |
2014-09-30 06:23:17 |
Cryo Capability |
|
Cryo Industries Cryocool-LHe |
2014-09-30 12:27:23 |
Software: Classification |
Control/collection, Processing |
Control/data collection, Processing, Analysis |
2014-09-30 12:27:01 |
Lab Facilities |
COLD ROOM |
Sample preparation laboratory, cold room, glove boxes |
2014-09-30 12:26:34 |
Cryo Capability Details |
|
20-200 K |
2014-09-30 12:26:22 |
Cryo Capability |
|
Oxford, open flow liq He cryostream |
2014-09-30 12:25:33 |
Mirrors |
Vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff 4.5 to 14.5 keV |
Vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff variable 4.5 to 14.5 keV |
2014-09-30 12:25:25 |
Mirrors |
vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff 4.5 to 14.5 keV |
Vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff 4.5 to 14.5 keV |
2014-09-30 12:25:12 |
Monochromator |
LN2 cooled, Si(111), phi = 0 & 90. double-crystal, non-fixed exit slit |
Liquid nitrogen-cooled double crystal, non-fixed exit slit. |
2014-09-30 12:24:02 |
Secondary Contact: Email |
|
enelson@slac.stanford.edu |
2014-09-30 12:23:46 |
Secondary Contact: Name |
|
Erik Nelson |
2014-09-30 12:23:36 |
Status Details |
|
Open |
2014-09-30 12:22:13 |
Experiments Details |
Beamline 4-3 is a wiggler side-station beamline dedicated for X-ray absorption spectroscopy and EXAFS measurements on biological and environmental systems. This station enables tender X-ray measurement (S K-edge and up) and is setup with a He flight path from the beamline optics to the sample. The beam is collimated and unfocused to allow for high energy-resolution measurements on homogenous samples. 4-3 is equipped with a four-element solid-state silicon drift detector in addition to ionization chambers and lytle detectors. A liquid He cryostream allows for low-temperature measurements. A motorized sample holder stage allows sequential measurement on multiple samples without sample changeover delays. |
Beam line 4-3 is a wiggler side-station beam line for X-ray absorption spectroscopy and EXAFS measurements. This station enables tender X-ray measurement (S K-edge and up) and is setup with a He flight path from the beam line optics to the sample. The beam is collimated and unfocused to allow for high energy-resolution measurements on homogenous samples. 4-3 is equipped with a 4-element solid-state Si drift detector in addition to ionization chambers, PIPS and Lytle detectors. A liquid He cryostream allows for low-temperature measurements. A motorized sample holder stage allows sequential measurement on multiple samples without sample changeover delays. |
2014-09-25 07:14:46 |
Owner/Operator |
SSRL |
SSRL-SMB-XAS |
2014-09-25 07:12:03 |
Cryo Capability |
|
Oxford Cryojet |
2014-09-25 07:11:38 |
Cryo Capability Details |
Oxford one flow, liq He cryotream. |
Oxford open flow, liq He cryotream. |
2014-09-25 07:11:30 |
Cryo Capability Details |
|
Oxford one flow, liq He cryotream. |
2014-09-25 07:10:49 |
Cryo Capability |
|
Oxford Cryostream - 600 series |
2014-09-25 07:10:27 |
Cryo Capability |
|
Oxford Cryostream - 600 series |
2014-09-25 07:10:09 |
Detector: Type |
|
Ionization chambers, PIPS, Lytle, Hitachi HTA 4-element solid-state Si drift detector, electron-yield detector. |
2014-09-25 07:09:44 |
Monochromator |
LN2 cooled, Si(111), Ï? = 0 & 90. double-crystal, non-fixed exit slit |
LN2 cooled, Si(111), phi = 0 & 90. double-crystal, non-fixed exit slit |
2014-09-25 07:09:15 |
Experiments Details |
|
Beamline 4-3 is a wiggler side-station beamline dedicated for X-ray absorption spectroscopy and EXAFS measurements on biological and environmental systems. This station enables tender X-ray measurement (S K-edge and up) and is setup with a He flight path from the beamline optics to the sample. The beam is collimated and unfocused to allow for high energy-resolution measurements on homogenous samples. 4-3 is equipped with a four-element solid-state silicon drift detector in addition to ionization chambers and lytle detectors. A liquid He cryostream allows for low-temperature measurements. A motorized sample holder stage allows sequential measurement on multiple samples without sample changeover delays. |