2019-08-20 03:55:19 |
Goniometer Details |
Chi motion for crystal mounting, 2 theta motion |
Chi motion for crystal mounting, 2 theta motion, motorized crystal centering |
2019-08-20 03:53:59 |
Primary Contact: Email |
hbellamy@lsu.edu |
ngilbert@lsu.edu |
2019-08-20 03:53:39 |
Source Details |
7 T super-conducting, single pole wiggler |
7.5 T super-conducting, multiple pole wiggler |
2019-08-20 03:51:50 |
Primary Contact: Name |
Henry Bellamy |
Nathan Gilbert |
2015-04-23 06:37:38 |
Detector: Type |
CCD |
CCD |
2012-09-29 09:36:27 |
Wavelength (Å): Min |
(1)0.69 (2) 0.69 |
0.69 |
2012-09-29 09:36:07 |
Wavelength (Å): Min |
0.69 |
(1)0.69 (2) 0.69 |
2011-07-01 04:21:45 |
Hardware |
Several Linux machines for beamline control, data collection, and data processing. |
Linux PCs for beamline control, data collection, and data processing. 1 TB NAS |
2011-07-01 04:20:12 |
Backup Services |
Write CDs and DVDs, USB and eSATA hard drives. |
CDs, DVDs, external USB and SATA hard drives. |
2011-07-01 04:18:41 |
Lab Facilities |
COLD ROOM |
anaerobic chamber, cold room |
2011-07-01 04:17:15 |
Experiments Details |
cyberstar flourescence detector for MAD |
|
2011-07-01 04:15:11 |
Special Capabilities Details |
|
cyberstar flourescence detector for MAD |
2011-07-01 04:12:32 |
Spot Size (mm): Width |
0.9 |
0.8 |
2011-07-01 04:12:25 |
Spot Size (mm): Height |
0.3 |
0.26 |
2011-06-29 01:06:02 |
Special Capabilities |
|
Absorption Edges |
2011-06-29 01:05:13 |
Experiments Details |
|
cyberstar flourescence detector for MAD |
2011-06-29 01:03:45 |
Sample Handling: Robotics |
|
can mount directly from vial with chi motion |
2011-06-29 01:03:12 |
Sample Handling: Manual |
Any pin length, magnetic caps strongly preferred |
Any pin length, screw type vials strongly discouraged |
2011-06-29 12:58:47 |
Backup Services |
Write CDs and DVDs, Firewire (IEEE1394) and USB portable hard drives. |
Write CDs and DVDs, USB and eSATA hard drives. |
2011-06-29 12:56:50 |
Software: Name |
MX for beamline control, marccd for data collection, HKL2000, Mosflm, CCP4, CNS, O, phenix, coot, Solve |
MX for beamline control, marccd for data collection, HKL2000, iMosflm, CCP4, phenix, coot |
2011-06-29 12:56:03 |
Lab Facilities |
anaerobic chamber |
COLD ROOM |
2011-06-29 12:55:09 |
Lab Facilities |
Cold room |
anaerobic chamber |
2011-06-29 12:54:21 |
Detector: Details |
|
distance 70 - 380 mm, 2 theta 0 - 30 deg |
2011-06-29 12:51:47 |
Flux Details |
200 micron square aperature - measured at 8990 eV 100 mA ring current |
200 micron square aperature - measured at 8980 eV 100 mA ring current |
2011-06-29 12:51:28 |
Flux Details |
400 micron aperature - measured at 8990 eV |
200 micron square aperature - measured at 8990 eV 100 mA ring current |
2011-06-29 12:50:18 |
Spot Size (mm): Width |
1.6 |
0.9 |
2011-06-29 12:50:02 |
Spot Size (mm): Height |
0.5 |
0.3 |
2011-06-29 12:47:15 |
Services |
Mail-in |
Mail-in, On-site cyrstallization facility, Rapid access |
2011-06-29 12:46:39 |
Services |
Rapid access |
Mail-in |
2011-06-29 12:46:28 |
Services |
Mail-in, On-site cyrstallization facility |
Rapid access |
2011-06-29 12:45:37 |
Secondary Contact: Email |
fox@bloch.utmb.edu |
rofox@uh.edu |
2009-08-11 01:35:58 |
Cryo Capability Details |
|
cryojet under computer control |
2009-08-11 01:33:21 |
Services |
|
Mail-in, On-site cyrstallization facility |
2009-08-11 01:31:16 |
Sample Handling: Manual |
|
Any pin length, magnetic caps strongly preferred |
2009-08-11 01:30:09 |
Goniometer |
MARdtb with chi motion for crystal mounting. |
MARdtb |
2009-08-11 01:29:55 |
Goniometer Details |
|
Chi motion for crystal mounting, 2 theta motion |
2009-08-11 01:28:45 |
Software: Name |
Mar data collection control software, HKL2000, Mosflm, CCP4, CNS, O, XtalView, Solve |
MX for beamline control, marccd for data collection, HKL2000, Mosflm, CCP4, CNS, O, phenix, coot, Solve |
2009-08-11 01:16:40 |
Detector: Activated for Service |
2002-01-01 |
2002-03-14 |