2024-04-02 02:24:40 |
Source Type |
INSERTION DEVICE |
INSERTION DEVICE |
2024-04-02 02:23:04 |
Detector: Removed from Service |
|
2024-03-25 |
2024-04-02 02:20:42 |
Robotics: More Info |
SPINE pins, ESRF pucks, Uni-pucks |
Uni-pucks |
2024-04-02 02:20:32 |
Sample Handling: Manual |
SPINE sample holders |
SPINE sample holders are preferred |
2024-04-02 02:19:13 |
Flux Coefficient |
3 |
1 |
2024-04-02 02:18:32 |
Experiments Details |
HT data collection, in situ crystal screening, room temperature data collection |
Remote access, HT data collection, in situ crystal screening, room temperature data collection |
2024-04-02 02:18:04 |
Services |
Data collection, On-site cyrstallization facility, Processing |
Data collection, Processing, Rapid access |
2024-04-02 02:17:03 |
Services |
Data collection, High quality data collection, High speed data collection, Processing |
Data collection, On-site cyrstallization facility, Processing |
2024-04-02 02:14:06 |
Special Capabilities |
Absorption Edges, Adjustable Focus Mirrors, Serial Crystallography |
Absorption Edges, Adjustable Focus Mirrors, Serial Crystallography |
2024-04-02 02:13:36 |
Experiments Details |
HT data collection, SSX, in situ crystal screening, room temperature data collection |
HT data collection, in situ crystal screening, room temperature data collection |
2024-04-02 02:13:02 |
Special Capabilities |
Absorption Edges |
Absorption Edges, Adjustable Focus Mirrors, Serial Crystallography |
2024-04-02 02:12:24 |
Special Capabilities |
Absorption Edges, Adjustable Focus Mirrors, High Intensity, High Resolution, High Throughput, Humidity Control, Long Wavelength, Micro-diffraction |
Absorption Edges |
2024-04-02 02:11:43 |
Experiments Details |
HT screening, large unit cells, micro crystals, in situ crystal screening, room temperature data collection |
HT data collection, SSX, in situ crystal screening, room temperature data collection |
2024-04-02 01:58:53 |
Beamline Website |
https://www.maxiv.lu.se/accelerators-beamlines/beamlines/biomax/ |
https://www.maxiv.lu.se/beamlines-accelerators/beamlines/biomax/ |
2024-04-02 01:53:04 |
Primary Contact: Name |
Uwe Mueller |
Ana Gonzalez |
2024-04-02 01:52:33 |
Primary Contact: Email |
uwe.muller@maxiv.lu.se |
ana.gonzalez@maxiv.lu.se |
2017-09-25 02:30:53 |
Detector: Activated for Service |
info currently not available |
2016-10-27 |
2017-09-25 02:29:38 |
Experiments Details |
HT screening, large unit cells, micro crystals, in situ crystal screening |
HT screening, large unit cells, micro crystals, in situ crystal screening, room temperature data collection |
2017-09-25 02:29:15 |
Experiments |
MONOCHROMATIC |
MAD, SAD, MONOCHROMATIC |
2017-09-25 02:29:02 |
Experiments |
MAD, SAD |
MONOCHROMATIC |
2017-09-25 02:28:33 |
%Time Available (general use) |
|
50% |
2017-09-25 02:28:09 |
Status Details |
|
|
2017-09-25 02:28:06 |
Status |
Commissioning |
Operational |
2016-08-10 04:14:27 |
Lab Facilities |
Sample preparation, Bio-safety level 1, 4 deg Cold room |
Sample preparation lab, bio-safety level 1 lab, cold room |
2016-08-10 04:13:57 |
Lab Facilities |
Sample preparation, Bio safety level 1 laboratory |
Sample preparation, Bio-safety level 1, 4 deg Cold room |
2016-08-10 04:13:03 |
Lab Facilities |
|
Sample preparation, Bio safety level 1 laboratory |
2016-08-10 04:12:29 |
Cryo Capability Details |
|
95-300 K |
2016-08-10 04:12:00 |
Cryo Capability |
|
Oxford Cryojet |
2016-08-10 04:11:38 |
Detector: Details |
|
311x328 mm^2 active area, 75x75 micrometer ^2 pixel size |
2016-08-10 04:09:53 |
Detector: Type |
|
PIXEL |
2016-08-10 04:09:46 |
Detector: Model |
|
DECTRIS EIGER 16M |
2016-08-10 04:08:24 |
Goniometer Details |
|
100 nm sphere of confusion |
2016-08-10 04:07:45 |
Flux Details |
0.1 x 0.1 mrad^2 cxv divergence |
0.1 x 0.1 mrad^2 hxv divergence |
2016-08-10 04:07:35 |
Flux Details |
|
0.1 x 0.1 mrad^2 cxv divergence |
2016-08-09 10:02:59 |
Robotics: More Info |
|
SPINE pins, ESRF pucks, Uni-pucks |
2016-08-09 10:02:23 |
Sample Handling: Robotics |
|
ISARA |
2016-08-09 10:01:58 |
Sample Handling: Manual |
|
SPINE sample holders |
2016-08-09 10:01:29 |
Goniometer |
|
MD3-microdiffractometer with MK3 mini kappa |
2016-08-09 10:00:57 |
Energy Range (keV): Max |
|
25 |
2016-08-09 10:00:54 |
Energy Range (keV): Min |
|
5 |
2016-08-09 10:00:49 |
Wavelength (Å): Max |
|
2.5 |
2016-08-09 10:00:46 |
Wavelength (Å): Min |
|
0.5 |
2016-08-09 09:55:14 |
Flux Exponent |
|
13 |
2016-08-09 09:55:09 |
Flux Coefficient |
|
3 |
2016-08-09 09:54:47 |
Monochromator |
Si111 double crystal monochromator |
Double crystal monochromator |
2016-08-09 09:46:27 |
Mirrors |
|
KB-Si mirror system |
2016-08-09 09:46:03 |
Optics Details |
Horizontally diffracting |
Horizontally deflecting |
2016-08-09 09:45:31 |
Crystal Type |
|
Si111 |
2016-08-09 09:45:22 |
Optics Details |
|
Horizontally diffracting |
2016-08-09 09:45:00 |
Monochromator |
horizontally diffracting double crystal monochromator |
Si111 double crystal monochromator |
2016-08-09 09:44:44 |
Monochromator |
horizontally diffracting double crystal monochromator |
horizontally diffracting double crystal monochromator |
2016-08-09 09:44:29 |
Monochromator |
|
horizontally diffracting double crystal monochromator |
2016-08-09 09:43:47 |
Spot Size (mm): Width |
|
0.020 |
2016-08-09 09:43:40 |
Spot Size (mm): Height |
|
0.005 |
2016-08-09 09:43:23 |
Source Details |
|
in vacuum undulator, 18mm period length |
2016-08-09 09:42:48 |
Source Type |
|
INSERTION DEVICE |
2016-08-09 09:42:42 |
Services |
|
Data collection, High quality data collection, High speed data collection, Processing |
2016-08-09 09:41:43 |
Special Capabilities |
|
Absorption Edges, Adjustable Focus Mirrors, High Intensity, High Resolution, High Throughput, Humidity Control, Long Wavelength, Micro-diffraction |
2016-08-09 09:40:53 |
Experiments Details |
HT screening, large unit cells, micro crystals, in situ screening |
HT screening, large unit cells, micro crystals, in situ crystal screening |
2016-08-09 09:40:43 |
Experiments Details |
|
HT screening, large unit cells, micro crystals, in situ screening |
2016-08-09 09:39:57 |
Experiments |
|
MAD, SAD |
2016-08-09 09:39:05 |
Status |
Operational |
Commissioning |
2016-08-09 09:38:58 |
Owner/Operator |
|
MAX IV |
2016-08-09 09:38:41 |
Beamline Website |
https://www.maxlab.lu.se/biomax |
https://www.maxiv.lu.se/accelerators-beamlines/beamlines/biomax/ |
2016-08-09 09:38:04 |
Secondary Contact: Email |
|
thomas.ursby@maxiv.lu.se |
2016-08-09 09:37:39 |
Secondary Contact: Name |
|
Thomas Ursby |
2016-08-08 11:25:09 |
Beamline Website |
|
https://www.maxlab.lu.se/biomax |
2016-08-08 11:24:35 |
Primary Contact: Name |
Uwe Muller |
Uwe Mueller |
2016-08-08 11:24:20 |
Primary Contact: Email |
|
uwe.muller@maxiv.lu.se |
2016-08-08 11:24:02 |
Primary Contact: Name |
|
Uwe Muller |
2016-08-08 11:23:53 |
Status |
|
Operational |