2011-12-14 04:19:13 |
Special Capabilities Details |
The multipole wiggler spectrum includes high photon flux at low energies, allowing optimisation of the anomalous signal at the Sulphur, Xenon and Calcium edges. |
The multipole wiggler spectrum includes high photon flux at low energies, allowing optimisation of the anomalous signal for Sulphur, Xenon and Calcium. |
2011-12-12 01:12:34 |
Sample Handling: Robotics |
|
Elettra Sample Changer |
2011-12-12 01:10:08 |
Backup Services |
4mm DAT, DVD, CD and connection of user's own laptop |
DVD, CD , connection of user's own laptop and USB devices |
2011-12-12 01:08:18 |
Detector: Activated for Service |
info currently not available |
2010-03-01 |
2011-12-12 01:07:56 |
Detector: Details |
|
The detector operates in single-photon-counting mode and has a large active area of 254x289 mm2, high dynamic range (2,000,000 counts per pixel), high frame rate (30 Hz) and minimal readout time of 3.6 ms. Images can be analyzed via XDS, imosflm and fit2d. |
2011-12-12 01:05:52 |
Detector: Type |
IMAGE PLATE |
PILATUS |
2011-12-12 01:05:51 |
Detector: Model |
MAR Scanner 345 mm |
2M |
2011-12-12 01:04:44 |
Robotics: More Info |
|
SPINE pins |
2011-12-12 12:56:38 |
Energy Range (keV): Max |
22 |
21.5 |
2011-12-12 12:56:27 |
Wavelength (Å): Min |
0.50 |
0.58 |
2011-12-12 12:55:23 |
Monochromator |
Double Crystal or white beaml |
Double Crystal or white beam |
2011-12-12 12:55:13 |
Spot Size (mm): Width |
0.3 |
0.200 |
2011-12-12 12:55:06 |
Spot Size (mm): Height |
2.0 |
0.200 |
2011-12-12 12:54:55 |
Spot Size (mm): Height |
2.0 |
2.0 |
2011-12-12 12:54:30 |
Source Details |
NdBFe multipole Wiggler |
NdBFe multipole Wiggler |
2011-12-12 12:54:26 |
Source Details |
NdBFe multipole Wiggler |
NdBFe multipole Wiggler |
2011-12-12 12:54:21 |
Source Type |
INSERTION DEVICE |
INSERTION DEVICE |
2011-12-12 12:54:12 |
Services Details |
|
|
2011-12-12 12:54:07 |
Services |
|
Data collection, On-site cyrstallization facility, Processing, Rapid access |
2011-12-12 05:50:39 |
Special Capabilities |
High Throughput, Long Wavelength |
Absorption Edges, Automated Sample Screening, High Pressure, High Resolution, High Throughput, Long Wavelength |
2011-12-12 05:50:07 |
Experiments Details |
|
The beamline has been designed primarily for macromolecular crystallography.The tunability of the wavelength provides the opportunity to use the Multiwavelength Anomalous Diffraction (MAD) technique for solving the phase problem over a broad range of wavelengths, covering the absorption edges of all the heavy atoms commonly used in protein crystallography. The multipole wiggler spectrum includes high photon flux at low energies, allowing optimisation of the anomalous signal at the Sulphur, Xenon and Calcium edges. Helium purged beampath and helium based cryo-cooling at 100 K are available for data-collection experiments with long wavelengths.The beamline hosts also small molecules crystallography, protein crystallography, powder diffraction, high pressure physics, solid-state experiments. |
2011-12-12 05:46:55 |
Experiments |
MAD, SAD, TIME RESOLVED LAUE, HIGH PRESSURE, POWDER |
MAD, SAD, MONOCHROMATIC, FLUORESCENCE, HIGH PRESSURE, POWDER, SOLUTION STUDIES |
2011-12-12 05:14:29 |
Special Capabilities |
Absorption Edges, Adjustable Focus Mirrors, High Pressure, High Resolution, Long Wavelength |
High Throughput, Long Wavelength |
2011-12-12 05:14:15 |
Special Capabilities |
Absorption Edges, Long Wavelength |
Absorption Edges, Adjustable Focus Mirrors, High Pressure, High Resolution, Long Wavelength |
2011-12-12 05:12:54 |
Owner/Operator |
|
Sincrotrone Trieste and CNR |
2011-12-12 05:12:32 |
Beamline Website |
http://www.elettra.trieste.it/experiments/beamlines/xrd1/index.html |
|
2010-11-26 04:24:33 |
Detector: Removed from Service |
2010-04-01 |
2010-02-01 |
2010-11-26 04:23:25 |
Removed from Service: Details |
|
Substituted by the Pilatus 2M, but still available |
2010-11-26 04:23:22 |
Detector: Details |
Substituted by the Pilatus 2M, but still available |
|
2010-11-26 04:22:43 |
Detector: Details |
Installed on 2theta arm of the Kappa Goniometer |
|
2010-11-26 04:21:00 |
Status |
operational |
Operational |
2010-11-26 04:20:39 |
Hardware |
Linux PC workstations, SG Indy and O2 workstations, 4-processor Compaq Alpha SE server. |
Linux PC workstations |
2010-11-26 04:19:37 |
Software: Name |
HKL suite (Xdisp, Denzo and Scalepack), Mosflm and XDS |
CCP4 suite (iMosflm) |
2010-11-26 04:18:52 |
Detector: Details |
Substituted by the Pilatus 2M, still available |
Substituted by the Pilatus 2M, but still available |
2010-11-26 04:18:42 |
Detector: Details |
|
Substituted by the Pilatus 2M, still available |
2010-11-26 04:17:29 |
Detector: Removed from Service |
|
2010-04-01 |
2010-11-26 04:16:43 |
Detector: Details |
|
Installed on 2theta arm of the Kappa Goniometer |
2010-11-26 04:13:38 |
Goniometer |
Kappa Goniometer |
Huber Kappa Goniometer |
2010-11-26 04:13:21 |
Goniometer |
Single axis goniostat (horizontal) |
Kappa Goniometer |
2010-11-26 04:11:07 |
Crystal Type |
Si111 - Si220 |
Si111 |
2010-11-26 04:09:57 |
Secondary Contact: Email |
giorgio.bais@elettra.trieste.it |
alberto.cassetta@ic.cnr.it |
2010-11-26 04:09:41 |
Secondary Contact: Name |
Bais Giorgio |
Cassetta Alberto |
2010-11-10 07:18:28 |
Secondary Contact: Name |
Bais Giorgio |
Bais Giorgio |