2023-03-01 01:48:52 Services Remote access
2023-03-01 01:48:03 Robotics: More Info 29 Universal puck capacity dewar 29 Universal Puck capacity dewar
2023-03-01 01:47:46 Robotics: More Info 29 Universal puck capacity dewar
2023-03-01 01:47:22 Sample Handling: Robotics ISARA2 sample changer
2023-03-01 01:46:30 Experiments Details Atomic resolution data collection, Long wavelength phasing Atomic resolution data collection, Ligand screening, Chemical crystallography
2022-06-09 11:47:30 Detector: Model DECTRIS PILATUS3 2M MAR 165 mm
2022-06-09 11:47:16 Detector: Model DECTRIS PILATUS3 2M RAYONIX MX-225
2022-06-09 11:46:59 Detector: Model DECTRIS PILATUS3 2M MAR Scanner 345 mm
2022-06-09 10:18:47 Detector: Model DECTRIS PILATUS 2M DECTRIS PILATUS3 2M
2022-06-09 10:17:42 Goniometer Details Single omega axis
2022-06-09 10:17:36 Goniometer MARdtb goniostat home-built
2013-03-06 02:52:25 Backup Services DVDs, USB2 drives, Firewire, DAT-4, Notebook connected to 100 Mbit switched network with IP-forwarding, ftp USB2+3 drives, Notebook connected to 100 Mbit switched network with IP-forwarding, ftp, sftp
2013-03-06 02:52:03 Hardware HP DL380 G5 2x Dualcore Xeon 3.1 GHz, 8 GB RAM 1TB Disk space on SAN array HP DL580 G7, 256 GB RAM, 3TB Disk space on SAN array
2013-03-06 02:51:11 Software: Name HKL2000, CCP4, XDS, Solve/Resolve, SHELX, XPREP, COOT, etc. CCP4, XDS, Solve/Resolve, SHELX, XPREP, COOT, XDSAPP, XDSIT, Phenix
2013-03-06 02:50:55 Lab Facilities Sample preparation laboratory: http://www.mx.bessy.de/userguide/wetlab NORMAL
2013-03-06 02:50:47 Cryo Capability Details 95-293 K
2013-03-06 02:50:23 Goniometer Details Single omega axis
2013-03-06 02:50:03 Flux Details 100 mA @ 12.4 keV - focus dim in hxv(micro m) = 190 x 90 /Phot/s/100 mA @ 12.4 keV/0.05%bw
2013-03-06 02:49:19 Flux Details 100 ma @ 12.4 keV - focus dim in hxv(micro m) = 190 x 90 100 mA @ 12.4 keV - focus dim in hxv(micro m) = 190 x 90
2013-03-06 02:48:47 Crystal Type Si(111) Si111
2013-03-06 02:48:39 Optics Details Sagitally bended Si111 crystal
2013-03-06 02:48:27 Spot Size (mm): Width 0.02 0.2
2013-03-06 02:48:21 Spot Size (mm): Height 0.05 0.2
2013-03-06 02:48:08 Experiments Details Atomic resolution data collection, Long wavelength phasing
2013-03-06 02:47:36 Beamline Website http://www.bessy.de/bit/bit_show_object.html.php?i_bit_id_object=36 http://www.helmholtz-berlin.de/forschung/funkma/soft-matter/forschung/bessy-mx/beamlines/bl14-2/index_en.html
2013-03-06 02:47:06 Secondary Contact: Email manfred.weiss@helmholtz-berlin.de
2013-03-06 02:46:50 Secondary Contact: Name Manfred S. Weiss
2013-03-06 02:46:39 Primary Contact: Email umue@bessy.de umue@helmholtz-berlin.de
2010-09-29 08:54:11 Beamline Website http://www.mx.bessy.de/userguide/beamlines/bl2/bl2.shtml http://www.bessy.de/bit/bit_show_object.html.php?i_bit_id_object=36
2009-10-12 02:52:06 Special Capabilities Details 266nm pulsed laser (TEM photonics, SNP series) 0.8 A high resolution limit
2009-10-12 02:51:36 Special Capabilities High Resolution
2009-10-12 02:51:15 Experiments Details UVRIP also available
2009-10-12 02:51:00 Owner/Operator Freie Universit t Berlin Freie Universitaet Berlin