Change history for BESSY - 14.1

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2025-01-31 01:39:07 Backup Services USB2+3 drives, Notebook connected to 100 Mbit switched network with IP-forwarding, ftp, sftp USB2+3 drives, local service only
2025-01-31 01:38:40 Hardware HP-DL560-Gen8, 512 GB RAM 21 TB SAN based data storage HP-DL560-Gen8, 512 GB RAM 32 TB SAN based data storage
2025-01-31 01:35:47 Removed from Service: Details Upgrade
2025-01-31 01:35:36 Detector: Removed from Service 2024-12-19
2025-01-31 01:34:40 Detector: Model DECTRIS PILATUS 6M DECTRIS PILATUS 6M
2025-01-31 01:34:28 Detector: Model DECTRIS PILATUS3 S 6M DECTRIS PILATUS 6M
2025-01-31 01:33:55 Spot Size (mm): Height 0.05 0.02
2025-01-31 01:33:42 Source Type INSERTION DEVICE
2025-01-31 01:33:35 Services Details F2X-Fragment screening facility
2025-01-31 01:33:16 Services High quality data collection, High speed data collection, Mail-in, On-site cyrstallization facility, Processing High quality data collection, High speed data collection, Processing, Rapid access, Structure refinement
2025-01-31 01:32:32 Services Processing High quality data collection, High speed data collection, Mail-in, On-site cyrstallization facility, Processing
2025-01-31 01:32:20 Services High quality data collection Processing
2025-01-31 01:32:03 Services High quality data collection
2025-01-31 01:31:37 Special Capabilities Long Wavelength Automated Sample Screening
2025-01-31 01:31:16 Experiments Details UV-RIP, Long wavelength phasing UV-RIP, Long wavelength phasing, HT-screening
2025-01-31 01:30:21 Beamline Website http://www.helmholtz-berlin.de/forschung/funkma/soft-matter/forschung/bessy-mx/beamlines/bl14-1/index_en.html https://www.helmholtz-berlin.de/forschung/oe/ps/macromolecular-crystallography/beamlines-and-experimental-stations/bl14-1_en.html
2022-06-09 11:51:18 Detector: Removed from Service 2020-01-01
2022-06-09 11:51:11 Detector: Activated for Service info currently not available 2013-01-01
2022-06-09 11:50:57 Detector: Activated for Service 2012-12-17 2020-01-01
2022-06-09 11:44:39 Detector: Model DECTRIS PILATUS2 6M DECTRIS PILATUS3 S 6M
2022-06-09 11:43:38 Detector: Model DECTRIS PILATUS2 6M MARmosaic 225
2022-06-09 10:25:16 Detector: Model DECTRIS PILATUS 6M DECTRIS PILATUS2 6M
2022-06-09 10:23:58 Detector: Model DECTRIS Pilatus3 6M DECTRIS PILATUS3 S 6M
2021-09-24 01:03:01 Primary Contact: Email Uwe.mueller@helmholtz-berlin.de uwe.mueller@helmholtz-berlin.de
2021-09-24 01:02:53 Primary Contact: Email umue@helmholtz-berlin.de Uwe.mueller@helmholtz-berlin.de
2021-09-24 01:02:39 Status Details Remote Access possible
2021-09-24 01:00:49 Detector: Model DECTRIS PILATUS 6M DECTRIS Pilatus3 6M
2021-09-24 01:00:06 Robotics: More Info SPINE pins required 9 Universal pucks supported within the dewar
2016-08-16 11:04:06 Owner/Operator Helmholtz Zentrum Berlin für Materialien und Energie Helmholtz Zentrum Berlin fur Materialien und Energie
2013-03-15 09:29:38 Detector: Activated for Service 2013-02-01 2012-12-17
2013-03-06 02:45:18 Backup Services DVDs, USB2 drives, Firewire, DAT-4, Notebook connected to 100 Mbit switched network with IP-forwarding, ftp USB2+3 drives, Notebook connected to 100 Mbit switched network with IP-forwarding, ftp, sftp
2013-03-06 02:44:48 Hardware HP-DL380-G5 server 1 Tb SAN based data storage HP-DL560-Gen8, 512 GB RAM 21 TB SAN based data storage
2013-03-06 02:44:11 Software: Name HKL2000, CCP4, XDS, Solve/Resolve, SHELX, XPREP, COOT, etc. CCP4, XDS, Solve/Resolve, SHELX, XPREP, COOT, XDSAPP, XDSIT, PHENIX
2013-03-06 02:43:43 Lab Facilities BIOHAZARD NORMAL
2013-03-06 02:43:39 Lab Facilities BIOHAZARD
2013-03-06 02:43:29 Lab Facilities Sample preparation- and bio-laboratory: www.mx.bessy.de/userguide/wetlab
2013-03-06 02:43:01 Cryo Capability Details 95-293 K
2013-03-06 02:42:15 Detector: Activated for Service 2006-07-30 2013-02-01
2013-03-06 02:41:33 Detector: Model RAYONIX MX225 DECTRIS PILATUS 6M
2013-03-06 02:41:28 Detector: Type CCD PIXEL
2013-03-06 02:41:14 Robotics: More Info SPINE pins required
2013-03-06 02:40:50 Sample Handling: Manual Possible
2013-03-06 02:40:39 Goniometer Details On-axis-sample-microscope
2013-03-06 02:39:45 Optics Details Sagitally bended Si111-crystal
2013-03-06 02:39:15 Spot Size (mm): Width 0.1 (hxv FWHM] Can be further reduced by aperture exchange 0.05 (hxv FWHM]
2013-03-06 02:38:46 Spot Size (mm): Height 0.1 0.05
2013-03-06 02:38:20 Special Capabilities Details Sulfur SAD, MAD at long wavelength
2013-03-06 02:37:46 Experiments Details UVRIP also available UV-RIP, Long wavelength phasing
2013-03-06 02:37:09 Experiments MAD, SAD MAD, SAD, MONOCHROMATIC
2013-03-06 02:36:30 Owner/Operator BESSY Helmholtz Zentrum Berlin für Materialien und Energie
2013-03-06 02:36:10 Beamline Website http://www.bessy.de/bit/bit_show_object.html.php?i_bit_id_object=35 http://www.helmholtz-berlin.de/forschung/funkma/soft-matter/forschung/bessy-mx/beamlines/bl14-1/index_en.html
2013-03-06 02:35:35 Secondary Contact: Email manfred.weiss@helmholtz-berlin.de
2013-03-06 02:34:55 Secondary Contact: Name Manfred S. Weiss
2013-03-06 02:34:39 Primary Contact: Email umue@bessy.de umue@helmholtz-berlin.de
2010-09-29 08:53:14 Beamline Website http://www.mx.bessy.de/userguide/beamlines/bl1/bl1.shtml http://www.bessy.de/bit/bit_show_object.html.php?i_bit_id_object=35