Change history for SPRING-8 - BL41XU

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2014-07-31 12:53:43 Detector: Model RAYONIX MX-225 HE DECTRIS PILATUS 6M
2014-07-31 12:52:32 Detector: Activated for Service info currently not available 2014-04-01
2014-07-31 12:52:01 Detector: Type PIXEL PIXEL
2014-07-31 12:51:02 Detector: Type MICROGAP PIXEL
2014-07-31 12:50:53 Detector: Type PIXEL MICROGAP
2014-07-31 12:50:29 Detector: Type CCD PIXEL
2014-07-31 12:50:14 Mirrors Rhodium-coated mirrors (horizontal and vertical) K-B mirrors fabricated with EEM (Elastic Emission Machining) technique (Osaka mirror)
2012-08-17 04:23:37 Software: Classification Processing Processing
2012-08-17 04:21:53 Robotics: More Info Sample Magazine: 2 uni-pucks Sample Magazine: 2 Uni-Pucks
2012-08-17 04:21:43 Robotics: More Info Two uni-pucks Sample Magazine: 2 uni-pucks
2012-08-17 04:18:24 Robotics: More Info Two uni-pucks
2012-08-17 04:15:12 Crystal Type Si (111)
2012-08-17 04:12:54 Special Capabilities Details semi-automatic sample centering. Semi-automatic sample centering.
2012-08-17 04:12:43 Experiments Details ultra-high resolution Ultra-high resolution
2012-08-17 04:12:23 Beamline Website http://www.spring8.or.jp/wkg/BL41XU/instrument/lang-en/INS-0000000328/instrument_summary_view http://bioxtal.spring8.or.jp/en/BL/BL41XU/BL41XU_en.html
2012-08-17 04:11:00 Secondary Contact: Email bioxtal@spring8.or.jp
2012-08-17 04:10:51 Secondary Contact: Name Takashi Kumasaka
2012-08-17 04:10:30 Software: Name CrystalClear (RIGAKU/MSC), HKL2000 (HKL Research, Inc.) HKL2000 (HKL Research, Inc.)
2012-08-17 04:09:48 Spot Size (mm): Width 0.08-0.03, 0.02, 0.01 0.05, 0.03, 0.01
2012-08-17 04:09:35 Spot Size (mm): Height 0.08-0.03, 0.02, 0.01 0.05, 0.03, 0.01
2012-08-17 04:08:41 Primary Contact: Email nshimizu@spring8.or.jp kazuya@spring8.or.jp
2012-08-17 04:08:30 Primary Contact: Name Nobutaka Shimizu Kazuya Hasegawa
2011-06-27 10:08:22 Beamline Website http://bioxtal.spring8.or.jp/index_en.html http://www.spring8.or.jp/wkg/BL41XU/instrument/lang-en/INS-0000000328/instrument_summary_view
2010-10-26 09:40:54 Detector: Model ADSC Quantum 315 RAYONIX MX-225 HE
2010-10-26 09:40:43 Beamline Website http://www.spring8.or.jp/wkg/BL41XU/instrument/lang-en/INS-0000000328/instrument_summary_view http://bioxtal.spring8.or.jp/index_en.html
2009-10-06 04:58:41 Goniometer The air-bearing goniometer has a sample rotation axis and three translation axes (X, Y and Z) Single rotation axis
2009-10-06 04:57:03 Goniometer Details The air-bearing goniometer has a sample rotation axis and three translation axes (X, Y and Z)
2009-10-06 04:56:15 Goniometer The air-bearing goniometer has a sample rotation axis and a sample alignment axis and three translation axes (X, Y and Z) The air-bearing goniometer has a sample rotation axis and three translation axes (X, Y and Z)
2009-10-06 04:55:26 Goniometer The goniometer has a sample rotation axis and a sample alignment axis and three translation axes (X, Y and Z) The air-bearing goniometer has a sample rotation axis and a sample alignment axis and three translation axes (X, Y and Z)
2009-10-06 04:55:10 Goniometer The dual-axes goniometer has a sample rotation axis and a sample alignment axis and three translation axes (X, Y and Z) The goniometer has a sample rotation axis and a sample alignment axis and three translation axes (X, Y and Z)
2009-10-06 04:54:13 Flux Coefficient 1 1.5
2009-10-06 04:53:50 Flux Details @ 12.4 keV
2009-10-06 04:52:05 Spot Size (mm): Width 0.025 0.08-0.03, 0.02, 0.01
2009-10-06 04:51:49 Spot Size (mm): Height 0.08-0.03,0.02,0.01 0.08-0.03, 0.02, 0.01
2009-10-06 04:51:42 Spot Size (mm): Height 0.025 0.08-0.03,0.02,0.01
2009-10-06 04:51:03 Energy Range (keV): Max 34.46 35
2009-10-06 04:50:57 Energy Range (keV): Min 6.51 6.5
2009-10-06 04:50:49 Wavelength (Å): Max 1.907 1.90
2009-10-06 04:50:41 Wavelength (Å): Min 0.34 0.35
2009-10-06 04:40:17 Detector: Model ADSC Quantum 315
2009-10-06 04:40:07 Detector: Details Rigaku RAXIS-V, ADSC Q315
2009-10-06 04:40:01 Detector: Type IMAGE PLATE - CCD CCD
2009-10-06 04:26:34 %Time Available (general use) 80
2009-10-06 04:25:27 Software: Classification Processing
2009-10-06 04:24:45 Detector: Details Rigaku RAXIS-V, ADSC Q315
2009-10-06 04:24:10 Detector: Model
2009-10-06 04:23:23 Detector: Model RIGAKU RAXIS V - ADSC QUANTUM 315r
2009-10-06 04:22:37 Sample Handling: Robotics (SPACE) Spring-8 Precise Automatic Cryo-Sample Exchanger
2009-10-06 04:21:46 Mirrors rhodium-coated mirrors (horizontal and vertical) Rhodium-coated mirrors (horizontal and vertical)
2009-10-06 04:21:07 Monochromator Rotated-inclined double-crystalR Rotated-inclined double-crystal
2009-10-06 04:21:01 Monochromator rotated-inclined double-crystal Rotated-inclined double-crystalR
2009-10-06 04:20:38 Source Details In-vaccum Undulator
2009-10-06 04:20:20 Source Type insertion device INSERTION DEVICE
2009-10-06 04:19:51 Experiments MAD MAD, SAD, MONOCHROMATIC
2009-10-06 04:18:51 Status operational Operational
2009-10-06 04:16:23 Owner/Operator Japan Synchrotron Radiation Research Institute (JASRI)
2009-08-17 02:49:12 Primary Contact: Email nshimizu@spring8.or.jp
2009-08-17 02:48:59 Primary Contact: Name nobutaka Shimizu Nobutaka Shimizu
2009-08-17 02:48:54 Primary Contact: Name nobutaka Shimizu
2009-07-25 07:29:33 Beamline Website http://www.spring8.or.jp/wkg/BL41XU/instrument/lang-en/INS-0000000385/instrument_summary_view http://www.spring8.or.jp/wkg/BL41XU/instrument/lang-en/INS-0000000328/instrument_summary_view