Change history for SSRL - BL2-3

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2014-09-30 12:33:53 Experiments Details BL2-3 is a bending magnet side station dedicated to X-ray imaging and micro X-ray absorption spectroscopy as well as micro diffraction of biological, material, and geological samples. A Kirkpatrick-Baez mirrors system is used to achieve microfocus with a beam size of about 2 x 2 microns. BL2-3 is equipped with a Vortex Si drift detector and ionization chambers. Sample positions are controlled with submicron accuracy by two different sample stages depending on the experiment. BL2-3 is ideal for obtaining elemental maps of small samples (~10 microns to 25 mm) as well as performing spectroscopy on selected points in the sample (~2 x 2 microns). BL2-3 is a bending magnet side station dedicated to X-ray imaging and micro X-ray absorption spectroscopy as well as micro diffraction of biological, material, and geological samples. A Kirkpatrick-Baez mirrors system is used to achieve microfocus with a beam size of ~ 2 x 2 microns. BL2-3 is equipped with a Vortex Si drift detector and ionization chambers. Sample positions are controlled with submicron accuracy by two different sample stages depending on the experiment. BL2-3 is ideal for obtaining elemental maps of small samples (~10 microns to 25 mm) as well as performing spectroscopy on selected points in the sample (~2 x 2 microns).
2014-09-30 12:33:13 Software: Classification Control/data collection, Processing, Analysis
2014-09-30 12:32:52 Goniometer none None
2014-09-30 12:32:36 Mirrors none None
2014-09-30 12:32:29 Monochromator water cooled, double crystal, non-fixed exit slit Water cooled, double crystal, non-fixed exit slit
2014-09-30 12:32:23 Monochromator downward reflecting, double crystal water cooled, double crystal, non-fixed exit slit
2014-09-30 12:30:57 Services Data collection Data collection
2014-09-30 12:30:37 Experiments Details BL2-3 is a bending magnet side station dedicated to X-ray imaging and micro X-ray absorption spectroscopy as well as micro diffraction of biological, material, and geological samples. A Kirkpatrick-Baez mirrors system is used to achieve microfocus with a beam size of about 2 x 2 microns. Beamline 2-3 is equipped with a Vortex silicon drift detector and ionization chambers. Sample positions are controlled with submicron accuracy by two different sample stages depending on the experiment. 2-3 is ideal for obtaining elemental maps of small samples (about 10 microns to 25 mm) as well as performing spectroscopy on selected points in the sample (about 2 x2 microns). BL2-3 is a bending magnet side station dedicated to X-ray imaging and micro X-ray absorption spectroscopy as well as micro diffraction of biological, material, and geological samples. A Kirkpatrick-Baez mirrors system is used to achieve microfocus with a beam size of about 2 x 2 microns. BL2-3 is equipped with a Vortex Si drift detector and ionization chambers. Sample positions are controlled with submicron accuracy by two different sample stages depending on the experiment. BL2-3 is ideal for obtaining elemental maps of small samples (~10 microns to 25 mm) as well as performing spectroscopy on selected points in the sample (~2 x 2 microns).
2014-09-30 12:30:04 Status Details Open
2014-09-30 12:28:50 Secondary Contact: Email ckrest@slac.stanford.edu
2014-09-30 12:28:24 Secondary Contact: Name Courtney Roach
2014-09-25 07:20:36 Experiments Details BL2-3 is a bending magnet side station dedicated to X-ray imaging and micro X-ray absorption spectroscopy as well as micro diffraction of biological, material, and geological samples. A Kirkpatrick-Baez mirrors system is used to achieve microfocus with a beam size of about 2 x 2 microns. Beamline 2-3 is equipped with a Vortex silicon drift detector and ionization chambers. Sample positions are controlled with submicron accuracy by two different sample stages depending on the experiment. 2-3 is ideal for obtaining elemental maps of small samples (about 10 microns to 25 mm) as well as performing spectroscopy on selected points in the sample (about 2 x2 microns).
2014-09-25 07:20:24 Detector: Details Ionization chambers, Vortex Silicon Drift Detector, CCD detector for µXRD Ionization chambers, Vortex Silicon Drift Detector, CCD detector for micro XRD
2014-09-25 07:20:10 Services , High quality data collection Data collection