2021-03-02 12:42:37 |
Experiments |
MONOCHROMATIC |
MAD, SAD, MONOCHROMATIC |
2020-02-12 05:50:46 |
Detector: Model |
ADSC QUANTUM 315 |
None |
2020-02-12 05:39:42 |
Backup Services |
See: http://smb.slac.stanford.edu/public/facilities/computing/backup.html |
|
2020-02-12 05:39:36 |
Hardware |
See: http://smb.slac.stanford.edu/public/facilities/computing/ |
|
2020-02-12 05:39:29 |
Software: Name |
See: http://smb.slac.stanford.edu/public/facilities/software/ |
|
2020-02-12 05:39:22 |
Cryo Capability |
Oxford Cryojet |
NONE |
2020-02-12 05:39:11 |
Lab Facilities |
Biochemical lab with cold room |
NONE |
2020-02-12 05:38:24 |
Detector: Type |
CCD |
|
2020-02-12 05:38:01 |
Goniometer |
Huber Kappa-geometry goniometer |
|
2020-02-12 05:37:53 |
Energy Range (keV): Max |
14.5 |
|
2020-02-12 05:37:51 |
Energy Range (keV): Min |
6.0 |
|
2020-02-12 05:37:46 |
Wavelength (Å): Max |
2.07 |
|
2020-02-12 05:37:43 |
Wavelength (Å): Min |
0.85 |
|
2020-02-12 05:37:38 |
Flux Details |
Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV and 90 mA |
|
2020-02-12 05:37:33 |
Flux Exponent |
10 |
|
2020-02-12 05:37:28 |
Flux Coefficient |
1.5 |
|
2020-02-12 05:37:22 |
Mirrors |
1m Rh coated toroidal focusing mirror |
|
2020-02-12 05:37:17 |
Crystal Type |
Si(111) |
|
2020-02-12 05:37:12 |
Monochromator |
Double crystal, non fixed exit |
|
2020-02-12 05:37:06 |
Spot Size (mm): Width |
0.2 |
|
2020-02-12 05:37:02 |
Spot Size (mm): Height |
0.2 |
|
2020-02-12 05:36:52 |
Experiments |
MAD, SAD, MONOCHROMATIC |
MONOCHROMATIC |
2020-02-12 05:36:12 |
Secondary Contact: Email |
soltis@slac.stanford.du |
|
2020-02-12 05:36:07 |
Secondary Contact: Name |
Mike Soltis |
|
2020-02-12 05:36:02 |
Primary Contact: Email |
acohen@slac.stanford.edu |
|
2020-02-12 05:35:58 |
Primary Contact: Name |
Aina Cohen |
|
2020-02-12 05:35:39 |
Secondary Contact: Email |
|
soltis@slac.stanford.du |
2020-02-12 05:35:24 |
Primary Contact: Name |
|
Aina Cohen |
2020-02-12 05:35:16 |
Secondary Contact: Name |
|
Mike Soltis |
2020-02-12 05:35:06 |
Primary Contact: Email |
|
acohen@slac.stanford.edu |
2014-09-30 03:47:24 |
Lab Facilities |
NORMAL |
Biochemical lab with cold room |
2014-09-30 03:46:27 |
Lab Facilities |
NORMAL |
NORMAL |
2014-09-30 03:46:17 |
Lab Facilities |
Beamline coldroom Biochemical lab with cold room |
NORMAL |
2014-09-30 03:45:10 |
Sample Handling: Robotics |
(SAM) Stanford Automated Mounting System |
None |
2014-09-30 03:43:44 |
Mirrors |
1m Rh coated cylindrical |
1m Rh coated toroidal focusing mirror |
2014-09-30 03:43:22 |
Monochromator |
Double crystal, paralell |
Double crystal, non fixed exit |
2014-09-30 03:42:54 |
Spot Size (mm): Width |
0.2 mm; FWHM: 0.1 X 0.1 mm |
0.2 |
2014-09-30 03:42:23 |
Experiments |
MONOCHROMATIC |
MAD, SAD, MONOCHROMATIC |
2014-09-30 03:42:12 |
Status Details |
This is now a material science beamline |
This is now a materials science beamline |
2013-07-18 02:07:45 |
Sample Handling: Robotics |
ALS type automounter |
(SAM) Stanford Automated Mounting System |
2013-07-18 02:07:19 |
Sample Handling: Robotics |
(SAM) Stanford Automated Mounting System |
ALS type automounter |
2013-07-18 02:06:56 |
Services |
automated sample screening |
|
2013-07-18 02:06:38 |
Beamline Website |
http://smb.slac.stanford.edu/ |
|
2013-07-18 02:06:34 |
Secondary Contact: Email |
ana@slac.stanford.edu |
|
2013-07-18 02:06:27 |
Secondary Contact: Name |
Ana Gonzalez |
|
2013-07-18 02:06:22 |
Primary Contact: Email |
soltis@slac.stanford.edu |
|
2013-07-18 02:06:16 |
Primary Contact: Name |
Michael Soltis |
|
2013-07-18 02:04:59 |
Status Details |
|
This is now a material science beamline |
2013-07-18 02:04:40 |
Status |
Decommissioned |
Decommissioned |
2013-07-18 02:04:32 |
Owner/Operator |
SSRL-SMB-MC |
SSRL |
2010-11-16 08:20:57 |
Status |
operational |
Decommissioned |
2010-11-16 08:20:36 |
Experiments |
MAD, SAD |
MONOCHROMATIC |
2010-11-16 08:20:09 |
%Time Available (general use) |
100 |
0 |