2023-12-07 04:39:26 |
Goniometer |
|
MD-2S |
2023-12-07 04:37:36 |
Robotics: More Info |
ALS or UniPucks |
UniPuck V1 |
2023-12-07 04:37:21 |
Sample Handling: Robotics |
Crystal Logic Sample Mounter |
Irelec ISARA2 |
2022-01-03 09:44:35 |
Beamline Website |
|
https://www.bnl.gov/nsls2/beamlines/beamline.php?r=19-ID |
2022-01-03 09:42:55 |
Lab Facilities |
NONE |
NORMAL |
2022-01-03 09:42:48 |
Cryo Capability |
NONE |
Oxford Cryostream - 700 series |
2022-01-03 09:41:30 |
Robotics: More Info |
|
ALS or UniPucks |
2022-01-03 09:41:00 |
Energy Range (keV): Max |
|
14 |
2022-01-03 09:40:56 |
Energy Range (keV): Min |
|
6 |
2022-01-03 09:40:41 |
Sample Handling: Robotics |
ALS type automounter |
Crystal Logic Sample Mounter |
2022-01-03 09:39:57 |
Detector: Model |
DECTRIS PILATUS 2M |
DECTRIS Eiger2 9M XE |
2022-01-03 09:38:49 |
Mirrors |
|
Mechanical VFM |
2022-01-03 09:38:27 |
Monochromator |
DCM |
DCM with sagittal focusing |
2022-01-03 09:37:49 |
Crystal Type |
|
Si(111) with 6 deg offset |
2022-01-03 09:37:00 |
Monochromator |
|
DCM |
2022-01-03 09:36:48 |
Spot Size (mm): Width |
|
0.02 |
2022-01-03 09:36:43 |
Spot Size (mm): Height |
|
0.02 |
2022-01-03 09:36:02 |
Special Capabilities |
Microfocus |
null |
2022-01-03 09:35:25 |
Experiments |
null |
MAD, SAD, MONOCHROMATIC |
2022-01-03 09:34:42 |
Primary Contact: Name |
|
Kevin Battaile |
2022-01-03 09:34:24 |
Status |
Under construction |
Operational |
2022-01-03 09:34:17 |
Owner/Operator |
|
NYSBC |
2018-01-03 10:03:18 |
Detector: Model |
DECTRIS PILATUS 6M |
DECTRIS PILATUS 2M |
2018-01-03 10:03:13 |
Detector: Type |
CCD |
PIXEL |
2018-01-03 09:52:07 |
Backup Services |
Data transfer using Firewire Drives, Globus or Rsync |
|
2018-01-03 09:52:04 |
Hardware |
Numerous Linux workstations and a 20 TB Linux cluster |
|
2018-01-03 09:51:54 |
Lab Facilities |
Access to APCF with comprehensive wet lab, cold room and crystallization facilities |
NONE |
2018-01-03 09:51:43 |
Cryo Capability Details |
Liquid He cooling on special request |
|
2018-01-03 09:51:24 |
Cryo Capability |
null |
NONE |
2018-01-03 09:51:15 |
Cryo Capability |
Oxford Cryojet |
null |
2018-01-03 09:50:38 |
Removed from Service: Details |
Never |
|
2018-01-03 09:50:29 |
Detector: Details |
Pilatus3X 6M |
|
2018-01-03 09:50:03 |
Sample Handling: Robotics |
Bruker BruNo |
ALS type automounter |
2018-01-03 09:49:08 |
Detector: Type |
CCD |
CCD |
2018-01-03 09:48:11 |
Detector: Type |
PIXEL |
CCD |
2018-01-03 09:47:37 |
Robotics: More Info |
REGAKU and Unipucks |
|
2018-01-03 09:47:31 |
Sample Handling: Robotics |
Rigaku ACTOR |
Bruker BruNo |
2018-01-03 09:47:06 |
Sample Handling: Robotics |
Rigaku ACTOR |
Rigaku ACTOR |
2018-01-03 09:46:43 |
Sample Handling: Manual |
Magnetic mounts, 18 mm pins |
|
2018-01-03 09:46:18 |
Goniometer Details |
Single axis, home build |
|
2018-01-03 09:46:05 |
Goniometer |
High precision air-bearing goniostat |
|
2018-01-03 09:46:00 |
Energy Range (keV): Max |
18.5 |
|
2018-01-03 09:45:53 |
Energy Range (keV): Min |
6.1 |
|
2018-01-03 09:45:46 |
Wavelength (Å): Max |
0.670 |
|
2018-01-03 09:45:43 |
Wavelength (Å): Min |
2.032 |
|
2018-01-03 09:45:24 |
Flux Details |
1x10^13 X-ray photons/sec/mm2 |
|
2018-01-03 09:45:03 |
Mirrors |
Rosenbaum-Rock vertical focusing mirror |
|
2018-01-03 09:44:34 |
Crystal Type |
Si (111) |
|
2018-01-03 09:44:23 |
Optics Details |
Sagittal focusing 2nd crystal horizontal focusing |
|
2018-01-03 09:43:49 |
Monochromator |
Si (111) Rosenbaum-Rock double-crystal monochromator: liquid nitrogen cooled |
|
2018-01-03 09:43:13 |
Spot Size (mm): Width |
100 um |
|
2018-01-03 09:43:08 |
Spot Size (mm): Height |
20 um |
|
2018-01-03 09:42:59 |
Source Details |
APS Undulator A |
|
2018-01-03 09:42:21 |
Special Capabilities Details |
Extended crystallography services |
|
2018-01-03 09:40:57 |
Services Details |
Rapid data collection, automated data reduction and semi-automated structure determination |
|
2018-01-03 09:40:38 |
Services |
High quality data collection |
null |
2018-01-03 09:40:19 |
Special Capabilities |
High Throughput |
Microfocus |
2018-01-03 09:39:56 |
Experiments Details |
SAD, MAD, micro diffraction, atomic resolution, rapid data collection |
|
2018-01-03 09:39:46 |
Experiments |
MAD |
null |
2018-01-03 09:39:27 |
Experiments |
NEUTRON |
MAD |
2018-01-03 09:39:08 |
Experiments |
MAD |
NEUTRON |
2018-01-03 09:38:37 |
%Time Available (general use) |
75% |
|
2018-01-03 09:37:48 |
Status Details |
On-site & Remote access |
|
2018-01-03 09:37:24 |
Status |
Operational |
Under construction |
2018-01-03 09:37:14 |
Owner/Operator |
SBC-CAT |
|
2018-01-03 09:37:02 |
Beamline Website |
http://www.sbc.anl.gov |
|
2018-01-03 09:36:45 |
Secondary Contact: Email |
mradford@anl.gov |
|
2018-01-03 09:36:40 |
Secondary Contact: Name |
Michelle Radford |
|
2018-01-03 09:36:32 |
Primary Contact: Email |
andrzejj@anl.gov |
|
2018-01-03 09:36:00 |
Primary Contact: Name |
Andrzej Joachimiak |
|
2018-01-02 05:43:34 |
Primary Contact: Name |
Andrzej Joachimiak Test |
Andrzej Joachimiak |
2018-01-02 05:42:58 |
Primary Contact: Name |
Andrzej Joachimiak |
Andrzej Joachimiak Test |
2018-01-02 12:54:04 |
Beamline Website |
www.sbc.anl.gov |
http://www.sbc.anl.gov |
2017-09-13 03:30:29 |
Cryo Capability |
Oxford Cryojet |
Oxford Cryojet |
2017-09-13 03:30:17 |
Detector: Model |
DECTRIS PILATUS 6M |
DECTRIS PILATUS 6M |
2017-09-13 03:25:40 |
Detector: Model |
DECTRIS PILATUS 2M |
DECTRIS PILATUS 6M |
2017-09-13 03:20:01 |
Owner/Operator |
SBC/ANL DOE/BER |
SBC-CAT |
2017-09-13 03:18:07 |
Backup Services |
Several options available Firewire Drives, 10 GB network |
Data transfer using Firewire Drives, Globus or Rsync |
2017-09-13 03:02:24 |
Secondary Contact: Email |
alkire@anl.gov |
mradford@anl.gov |
2017-09-13 03:02:09 |
Secondary Contact: Name |
Randy Alkire |
Michelle Radford |
2017-09-13 03:01:20 |
Services Details |
Rapid data collection, automated data reduction and on-site semi-automated structure determination |
Rapid data collection, automated data reduction and semi-automated structure determination |
2017-09-13 03:00:26 |
Backup Services |
Several options available |
Several options available Firewire Drives, 10 GB network |
2017-09-13 02:59:55 |
Hardware |
Data storage system |
Numerous Linux workstations and a 20 TB Linux cluster |
2017-09-13 02:56:21 |
Mirrors |
Flat |
Rosenbaum-Rock vertical focusing mirror |
2017-09-13 02:55:58 |
Optics Details |
Sagittal focus horizontal focusing |
Sagittal focusing 2nd crystal horizontal focusing |
2017-09-13 02:55:38 |
Monochromator |
Double crystal monochromator |
Si (111) Rosenbaum-Rock double-crystal monochromator: liquid nitrogen cooled |
2017-09-13 02:54:30 |
Sample Handling: Robotics |
Rigaku ACTOR |
Rigaku ACTOR |
2017-09-13 02:54:23 |
Sample Handling: Manual |
Magnetic mounts |
Magnetic mounts, 18 mm pins |
2017-09-13 02:53:27 |
Robotics: More Info |
REGAKU and ALS pucks |
REGAKU and Unipucks |
2017-09-13 02:51:47 |
Lab Facilities |
NORMAL |
Access to APCF with comprehensive wet lab, cold room and crystallization facilities |
2017-09-13 02:50:56 |
Cryo Capability |
Oxford Cryostream - 700 series |
Oxford Cryojet |
2017-09-13 02:50:39 |
Removed from Service: Details |
|
Never |
2017-09-13 02:50:27 |
Sample Handling: Manual |
magnetic mounts |
Magnetic mounts |
2017-09-13 02:50:18 |
Goniometer Details |
single axis, home build |
Single axis, home build |
2017-09-13 02:50:12 |
Goniometer |
High precision air-bearing goniosta |
High precision air-bearing goniostat |
2017-09-13 02:50:07 |
Goniometer |
high precision air-bearing goniosta |
High precision air-bearing goniosta |
2017-09-13 02:49:08 |
Optics Details |
Sagittal focus |
Sagittal focus horizontal focusing |
2017-09-13 02:48:45 |
Monochromator |
Double crystal monochromator |
Double crystal monochromator |
2017-09-13 02:48:04 |
Services Details |
Rapid data collection |
Rapid data collection, automated data reduction and on-site semi-automated structure determination |
2017-09-13 02:47:16 |
Services |
High quality data collection |
High quality data collection |
2017-09-13 02:46:24 |
Special Capabilities |
Microfocus |
High Throughput |
2017-09-13 02:45:53 |
Experiments Details |
SAD, MAD, atomic resolution, rapid data collection |
SAD, MAD, micro diffraction, atomic resolution, rapid data collection |
2017-09-13 02:45:35 |
Experiments |
SAD |
MAD |
2017-09-13 02:38:42 |
Backup Services |
|
Several options available |
2017-09-13 02:38:21 |
Hardware |
|
Data storage system |
2017-09-13 02:37:09 |
Detector: Type |
CCD |
PIXEL |
2017-09-13 02:36:05 |
Cryo Capability Details |
|
Liquid He cooling on special request |
2017-09-13 02:34:48 |
Flux Details |
1x10^13 |
1x10^13 X-ray photons/sec/mm2 |
2017-09-13 02:34:19 |
Flux Details |
|
1x10^13 |
2017-09-13 02:31:48 |
Mirrors |
glass |
Flat |
2017-09-13 02:31:12 |
Crystal Type |
silica |
Si (111) |
2017-09-13 02:30:53 |
Optics Details |
|
Sagittal focus |
2017-09-13 02:29:50 |
Monochromator |
double crystal monochromator |
Double crystal monochromator |
2017-09-13 02:29:40 |
Source Type |
INSERTION DEVICE |
INSERTION DEVICE |
2017-09-13 02:29:34 |
Services Details |
|
Rapid data collection |
2017-09-13 02:29:17 |
Special Capabilities Details |
extended crystallography |
Extended crystallography services |
2017-09-13 02:29:04 |
Special Capabilities Details |
|
extended crystallography |
2017-09-13 02:28:42 |
Experiments |
SAD |
SAD |
2017-09-13 02:28:29 |
Owner/Operator |
DOE BER |
SBC/ANL DOE/BER |
2017-09-13 02:27:53 |
Status |
Under construction |
Operational |
2017-09-13 02:27:40 |
Lab Facilities |
NONE |
NORMAL |
2017-09-13 02:27:16 |
Cryo Capability |
NONE |
Oxford Cryostream - 700 series |
2017-09-13 02:27:05 |
Detector: Activated for Service |
info currently not available |
2016-02-01 |
2017-09-13 02:26:36 |
Detector: Details |
|
Pilatus3X 6M |
2017-09-13 02:24:36 |
Robotics: More Info |
|
REGAKU and ALS pucks |
2017-09-13 02:23:52 |
Sample Handling: Robotics |
ALS type automounter |
Rigaku ACTOR |
2017-09-13 02:23:41 |
Sample Handling: Manual |
|
magnetic mounts |
2017-09-13 02:23:16 |
Goniometer Details |
|
single axis, home build |
2017-09-13 02:22:48 |
Goniometer |
|
high precision air-bearing goniosta |
2017-09-13 02:21:02 |
Energy Range (keV): Max |
|
18.5 |
2017-09-13 02:20:55 |
Energy Range (keV): Min |
|
6.1 |
2017-09-13 02:20:48 |
Wavelength (Å): Max |
|
0.670 |
2017-09-13 02:19:59 |
Wavelength (Å): Min |
|
2.032 |
2017-09-13 02:19:43 |
Mirrors |
|
glass |
2017-09-13 02:19:36 |
Crystal Type |
|
silica |
2017-09-13 02:19:28 |
Monochromator |
silicon crystal monochromator |
double crystal monochromator |
2017-09-13 02:18:09 |
Monochromator |
|
silicon crystal monochromator |
2017-09-13 02:15:52 |
Spot Size (mm): Width |
|
100 um |
2017-09-13 02:15:44 |
Spot Size (mm): Height |
100 um |
20 um |
2017-09-13 02:15:11 |
Spot Size (mm): Height |
|
100 um |
2017-09-13 02:14:57 |
Source Details |
|
APS Undulator A |
2017-09-13 01:05:42 |
Services |
null |
High quality data collection |
2017-09-13 01:04:55 |
Experiments Details |
SAD, MAD, atomic resolution, HTP data collection |
SAD, MAD, atomic resolution, rapid data collection |
2017-09-13 01:04:28 |
Experiments Details |
|
SAD, MAD, atomic resolution, HTP data collection |
2017-09-13 01:03:36 |
Experiments |
null |
SAD |
2017-09-13 01:03:28 |
%Time Available (general use) |
|
75% |
2017-09-13 01:03:18 |
Status Details |
|
On-site & Remote access |
2017-09-13 01:02:32 |
Owner/Operator |
|
DOE BER |
2017-09-13 01:01:36 |
Beamline Website |
|
www.sbc.anl.gov |
2017-09-13 01:00:47 |
Secondary Contact: Email |
|
alkire@anl.gov |
2017-09-13 01:00:07 |
Secondary Contact: Name |
|
Randy Alkire |
2017-09-13 12:59:53 |
Primary Contact: Email |
|
andrzejj@anl.gov |
2017-09-13 12:59:43 |
Primary Contact: Name |
|
Andrzej Joachimiak |
2017-04-24 01:04:08 |
Detector: Model |
Pilatus3 X 6M |
DECTRIS PILATUS 2M |
2017-04-24 01:04:07 |
Detector: Type |
PIXEL |
CCD |
2017-04-24 01:04:06 |
Sample Handling: Robotics |
Bruker BruNo |
ALS type automounter |
2017-04-24 01:04:05 |
Source Type |
INSERTION DEVICE |
INSERTION DEVICE |
2017-04-24 01:03:58 |
Backup Services |
Network connection for data transfer using Globus or Rsync. |
|
2017-04-24 01:03:53 |
Lab Facilities |
COLD ROOM |
NONE |
2017-04-24 01:03:47 |
Cryo Capability |
Oxford Cryostream |
NONE |
2017-04-24 01:03:15 |
Robotics: More Info |
18.0 mm pins |
|
2017-04-24 01:03:03 |
Sample Handling: Robotics |
Rigaku ACTOR |
Bruker BruNo |
2017-04-24 01:02:43 |
Goniometer Details |
-540 to +540 |
|
2017-04-24 01:02:41 |
Goniometer |
Spindle |
|
2017-04-24 01:02:37 |
Energy Range (keV): Max |
13.6 KeV |
|
2017-04-24 01:02:35 |
Energy Range (keV): Min |
6.1 KeV |
|
2017-04-24 01:02:28 |
Services |
Data collection, On-site cyrstallization facility, Rapid access |
null |
2017-04-24 01:02:20 |
Experiments |
MAD |
null |
2017-04-24 01:02:05 |
Spot Size (mm): Width |
0.020 |
|
2017-04-24 01:02:03 |
Spot Size (mm): Height |
0.100 |
|
2017-04-24 01:01:28 |
Special Capabilities |
Microfocus |
Microfocus |
2017-04-24 01:01:14 |
Experiments |
NEUTRON |
MAD |
2017-04-24 01:01:05 |
Experiments |
MAD, SAD, FLUORESCENCE |
NEUTRON |
2017-04-24 01:00:53 |
Status |
Operational |
Under construction |
2017-04-24 01:00:51 |
%Time Available (general use) |
75 |
|
2017-04-24 01:00:42 |
Owner/Operator |
SBC-CAT |
|
2017-04-24 01:00:41 |
Beamline Website |
www.sbc.anl.gov |
|
2017-04-24 01:00:38 |
Secondary Contact: Email |
mficner@anl.gov |
|
2017-04-24 01:00:36 |
Secondary Contact: Name |
Michelle Radford |
|
2017-04-24 01:00:34 |
Primary Contact: Name |
Andrzej Joachimiak |
|
2017-04-24 01:00:32 |
Primary Contact: Email |
andrzejj@anl.gov |
|
2016-09-12 05:38:52 |
Monochromator |
|
|
2016-09-12 05:28:44 |
Lab Facilities |
|
COLD ROOM |
2016-09-12 05:28:32 |
Special Capabilities |
Microfocus |
Microfocus |
2016-09-12 05:25:09 |
Robotics: More Info |
|
18.0 mm pins |
2016-09-12 05:19:53 |
Goniometer Details |
|
-540 to +540 |
2016-09-12 05:19:41 |
Goniometer |
|
Spindle |
2016-09-12 05:18:54 |
Cryo Capability |
|
Oxford Cryostream |
2016-09-12 05:18:13 |
Detector: Type |
|
PIXEL |
2016-09-12 05:17:46 |
Detector: Model |
|
Pilatus3 X 6M |
2016-09-12 05:10:24 |
Backup Services |
|
Network connection for data transfer using Globus or Rsync. |
2016-09-12 05:08:55 |
Energy Range (keV): Max |
|
13.6 KeV |
2016-09-12 05:08:45 |
Energy Range (keV): Min |
|
6.1 KeV |
2016-09-12 05:06:50 |
Spot Size (mm): Width |
|
0.020 |
2016-09-12 05:06:40 |
Spot Size (mm): Height |
|
0.100 |
2016-09-12 05:05:48 |
Special Capabilities |
Microfocus, Ultra Low Temperature |
Microfocus |
2016-09-12 05:04:59 |
Services |
Data collection, High speed data collection, On-site cyrstallization facility, Rapid access |
Data collection, On-site cyrstallization facility, Rapid access |
2016-09-12 05:04:38 |
Services |
Data collection, High quality data collection, High speed data collection, On-site cyrstallization facility, Rapid access |
Data collection, High speed data collection, On-site cyrstallization facility, Rapid access |
2016-09-12 05:03:58 |
Owner/Operator |
|
SBC-CAT |
2016-09-12 04:06:49 |
Sample Handling: Robotics |
|
Rigaku ACTOR |
2016-09-12 04:05:30 |
Source Type |
|
INSERTION DEVICE |
2016-09-12 04:05:23 |
Services |
|
Data collection, High quality data collection, High speed data collection, On-site cyrstallization facility, Rapid access |
2016-09-12 04:04:49 |
Special Capabilities |
|
Microfocus, Ultra Low Temperature |
2016-09-12 04:04:37 |
Experiments |
null |
MAD, SAD, FLUORESCENCE |
2016-09-12 04:04:17 |
Experiments |
|
null |
2016-09-12 04:04:07 |
%Time Available (general use) |
|
75 |
2016-09-12 04:03:52 |
Status |
Under construction |
Operational |
2016-09-12 04:02:04 |
Beamline Website |
|
www.sbc.anl.gov |
2016-09-12 04:01:56 |
Secondary Contact: Email |
|
mficner@anl.gov |
2016-09-12 04:01:49 |
Secondary Contact: Name |
|
Michelle Radford |
2016-09-12 04:01:42 |
Primary Contact: Email |
|
andrzejj@anl.gov |
2016-09-12 04:01:35 |
Primary Contact: Name |
|
Andrzej Joachimiak |