2023-08-17 02:25:33 |
Hardware |
128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations |
128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations |
2023-08-17 02:25:23 |
Software: Name |
AutoProcess (XDS, BEST, POINTLESS based automatic processing script), XDS, HKL2000, iMosflm |
MXproc (XDS, BEST, POINTLESS based automatic processing script), XDS, HKL2000, iMosflm |
2023-08-17 02:25:01 |
Removed from Service: Details |
|
Upgraded to Dectris Eiger 9M |
2023-08-17 02:24:31 |
Robotics: More Info |
SSRL cassette, Uni-puck |
Uni-puck |
2023-08-17 02:24:23 |
Sample Handling: Robotics |
(SAM) Stanford Automated Mounting System |
Irelec ISARA Automated Sample Changer, 29 puck capacity |
2023-08-17 02:23:28 |
Sample Handling: Manual |
18 mm Hampton pin is recommended |
Default: 18 mm pin in magnetic Hampton/Mitegen base. Alternative: Low-profile SBS standard plates |
2023-08-17 02:20:53 |
Goniometer Details |
|
Optional Plate Holder and Mini-Kappa attachments. Optional HC1 humidity control device |
2023-08-17 02:20:07 |
Goniometer |
MD2-S (Arinax) with SmartMagnet and Plate Holder. On-axis visualization (Arinax OAV-B) |
MD2-S (Arinax) with SmartMagnet. On-axis visualization (Arinax OAV-B-zoom), Bruker X-flash 410 fluorescence detector, and Oxford CryoJet |
2023-08-17 02:18:20 |
Goniometer |
Huber Model 410 with a single phi axis complemented with on-axis visulization system |
MD2-S (Arinax) with SmartMagnet and Plate Holder. On-axis visualization (Arinax OAV-B) |
2023-08-17 02:16:14 |
Wavelength (Å): Min |
0.69 |
0.62 |
2023-08-17 02:15:45 |
Wavelength (Å): Max |
1.9 |
2.48 |
2023-08-17 02:14:32 |
Detector: Removed from Service |
|
2020-05-01 |
2023-08-17 02:13:24 |
Flux Details |
flux measure at 12.658 keV at 250 mA |
Maximal flux measure at 12 keV (DCM) and 9.72 keV (DMM) at 200 mA |
2023-08-17 02:12:17 |
Flux Exponent |
12 |
12 (DCM) or 14 (DMM) |
2023-08-17 02:11:59 |
Flux Coefficient |
5 |
8.2 (DCM) or 1.2 (DMM) |
2023-08-17 02:11:09 |
Energy Range (keV): Min |
5 (DMM) or 7.2 (DCM) |
5 (DCM) or 7.2 (DMM) |
2023-08-17 02:10:55 |
Energy Range (keV): Max |
18 |
20 (DMM) or 10.4 (DMM) |
2023-08-17 02:10:39 |
Energy Range (keV): Min |
5 |
5 (DMM) or 7.2 (DCM) |
2023-08-17 02:10:20 |
Energy Range (keV): Min |
6.5 |
5 |
2023-08-17 02:08:30 |
Mirrors |
Vertically focussing Si(001) mirror |
Elliptically bent vertical and horizontal focussing Rh/Ir coated Si(001) crystals in a Kirkpatrick-Baez configuration. |
2023-08-17 02:02:26 |
Mirrors |
Vertically focusing mirror |
Vertically focussing Si(001) mirror |
2023-08-17 02:00:59 |
Monochromator |
Double Crystal Monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal |
Double Crystal Multilayer Monochromator (Axilon DCMM) comprising a pair of indirectly cryo-cooled Si(111) crystals (DCM) and Bo/B4C-coated Si(111) multilayers (300 bilayers, DMM mode) |
2023-08-17 01:58:32 |
Spot Size (mm): Width |
0.15 |
0.005-0.05 |
2023-08-17 01:58:24 |
Spot Size (mm): Height |
0.05 |
0.005-0.05 |
2023-08-17 01:52:57 |
%Time Available (general use) |
55 |
65 |
2022-05-26 01:14:53 |
Detector: Model |
MARmosaic 225 |
Eiger x 9M |
2022-05-26 01:14:51 |
Detector: Type |
CCD |
PIXEL |
2022-05-26 01:11:22 |
Secondary Contact: Email |
michel.fodje@lightsource.ca |
|
2022-05-26 01:11:15 |
Secondary Contact: Name |
Michel Fodje |
|
2022-05-26 01:11:00 |
Removed from Service: Details |
Upgraded to Rayonix MX-300 |
|
2022-05-26 01:10:24 |
Detector: Activated for Service |
202-05-10 |
2022-05-10 |
2022-05-26 01:10:03 |
Detector: Activated for Service |
2006-03-18 |
202-05-10 |
2022-05-26 01:06:01 |
Primary Contact: Name |
Pawel Grochulski Michel Fodje |
Michel Fodje |
2022-05-26 01:05:52 |
Primary Contact: Email |
pawel.grochulski@lightsource.ca |
michel.fodje@lightsource.ca |
2022-05-26 01:05:27 |
Primary Contact: Name |
Pawel Grochulski |
Pawel Grochulski Michel Fodje |
2017-09-26 06:13:34 |
Detector: Removed from Service |
2017-02-03 |
2020-01-01 |
2017-09-26 06:12:04 |
Detector: Removed from Service |
2017-02-03 |
2010-03-31 |
2017-09-26 06:09:45 |
Removed from Service: Details |
|
Upgraded to Dectris Pilatus 6M |
2017-09-26 06:09:25 |
Detector: Removed from Service |
|
2017-02-03 |
2011-07-05 08:46:06 |
Special Capabilities |
Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput, Humidity Control |
Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput |
2011-07-05 08:44:04 |
Special Capabilities |
Automated Sample Screening, High Intensity, High Resolution |
Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput, Humidity Control |
2011-07-05 08:43:07 |
Special Capabilities |
Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput |
Automated Sample Screening, High Intensity, High Resolution |
2011-02-22 03:34:50 |
Flux Coefficient |
2 |
5 |
2011-02-22 03:34:32 |
Services Details |
Mail-In |
|
2011-02-22 03:34:26 |
Services Details |
Mail-In |
Mail-In |
2011-02-22 03:34:17 |
Services |
Rapid access |
High quality data collection, Mail-in, Processing, Rapid access |
2011-02-22 03:33:32 |
Special Capabilities |
Automatic Crystal Alignment |
Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput |
2011-02-22 03:32:46 |
Experiments Details |
S-SAD |
|
2011-02-22 03:32:18 |
Experiments |
MAD |
MAD, SAD, MONOCHROMATIC, FLUORESCENCE |
2010-12-02 09:01:20 |
Spot Size (mm): Width |
0.13 |
0.15 |
2010-12-02 08:59:28 |
Goniometer |
Huber Model 410 with single phi axis and on-axis visulization system |
Huber Model 410 with a single phi axis complemented with on-axis visulization system |
2010-12-02 08:58:27 |
Goniometer |
Huber Model 410 with single phi axis |
Huber Model 410 with single phi axis and on-axis visulization system |
2010-09-22 11:41:55 |
Beamline Website |
http://exshare.lightsource.ca/cmcf/ |
http://cmcf.lightsource.ca |
2010-09-16 04:12:19 |
Hardware |
128-core SUN computing cluster with 8Tb RAID and 30 Tb of long-term storage. Precsion 360 user workstations |
128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations |
2010-09-16 04:11:48 |
Hardware |
128-core SUN computing cluster with 8Tb RAID and 30 Tb of lon-term storage. Precsion 360 user workstations |
128-core SUN computing cluster with 8Tb RAID and 30 Tb of long-term storage. Precsion 360 user workstations |
2010-09-16 04:10:23 |
Hardware |
SUN server with 8Tb Raid system, 30 Tb backup and Del Precsion 360 user workstations |
128-core SUN computing cluster with 8Tb RAID and 30 Tb of lon-term storage. Precsion 360 user workstations |
2010-09-14 02:09:03 |
Sample Handling: Manual |
Any magnetic pin bases but 18 mm Hampton pin is recommended |
18 mm Hampton pin is recommended |
2010-09-14 02:08:29 |
Special Capabilities Details |
High flux, |
High flux |
2010-09-14 02:08:23 |
Special Capabilities Details |
|
High flux, |
2010-09-14 02:07:53 |
Special Capabilities |
Automatic Crystal Alignment |
Automatic Crystal Alignment |
2010-09-14 02:07:42 |
Special Capabilities |
High Intensity |
Automatic Crystal Alignment |
2010-09-14 02:07:22 |
Special Capabilities Details |
|
|
2010-09-14 02:07:15 |
Special Capabilities |
Automated Sample Screening |
High Intensity |
2010-09-14 02:07:08 |
Special Capabilities |
Automatic Crystal Alignment |
Automated Sample Screening |
2010-09-14 02:06:51 |
Experiments Details |
|
S-SAD |
2010-09-14 02:06:42 |
Experiments |
MAD |
MAD |
2010-09-14 02:06:18 |
Services Details |
|
Mail-In |
2010-09-14 02:05:40 |
Services |
Data collection, High quality data collection, Mail-in, Rapid access |
Rapid access |
2010-09-14 02:07:52 |
Hardware |
SUN server and Del Precsion 360 user workstations |
SUN server with 8Tb Raid system, 30 Tb backup and Del Precsion 360 user workstations |
2010-09-14 02:01:39 |
Hardware |
Del Precsion 360 user workstations |
SUN server and Del Precsion 360 user workstations |
2010-09-14 02:01:18 |
Backup Services |
Archiver (automatic data archiver), DVD/Blu-Ray Robot |
Archiver for external USB disks, DVD/Blu-Ray Robot |
2010-09-14 01:59:01 |
Sample Handling: Manual |
Any magnetic pin bases but 18 mm Hampton pin is recomended |
Any magnetic pin bases but 18 mm Hampton pin is recommended |
2010-09-14 01:57:06 |
Sample Handling: Manual |
Prefered 18 mm Hampton CRYOPIN |
Any magnetic pin bases but 18 mm Hampton pin is recomended |
2010-09-14 01:53:38 |
Sample Handling: Manual |
18 mm Hampton CRYOPIN |
Prefered 18 mm Hampton CRYOPIN |
2010-09-14 01:51:19 |
Robotics: More Info |
SAM commissioning in progress |
SSRL cassette, Uni-puck |
2010-09-14 01:48:12 |
Sample Handling: Manual |
18 mm Hampton CRYOPIN |
18 mm Hampton CRYOPIN |
2010-09-14 01:46:27 |
Status |
operational |
Operational |
2010-09-13 06:11:42 |
Secondary Contact: Email |
michel.fodje@lightsource.ca.ca |
michel.fodje@lightsource.ca |
2010-09-13 06:11:29 |
Secondary Contact: Email |
mirek@bri.nrc.ca |
michel.fodje@lightsource.ca.ca |
2010-09-13 06:11:09 |
Secondary Contact: Name |
Pawel Grochulski |
Michel Fodje |
2010-09-13 06:10:44 |
Secondary Contact: Name |
Mirek Cygler |
Pawel Grochulski |
2010-09-13 02:12:31 |
Backup Services |
Automatic data archiver, DVD/Blu-Ray Robot (comming soon) |
Archiver (automatic data archiver), DVD/Blu-Ray Robot |
2010-09-13 02:11:23 |
Software: Name |
CCP4, COOT, PHENIX |
CCP4, PHENIX, COOT |
2010-07-02 03:48:45 |
Software: Name |
CCP4 |
CCP4, COOT, PHENIX |
2010-07-02 03:48:09 |
Software: Name |
AutoProcess (XDS, BEST, pointless based automatic processing script), XDS, HKL2000, iMosflm |
AutoProcess (XDS, BEST, POINTLESS based automatic processing script), XDS, HKL2000, iMosflm |
2010-07-02 03:47:48 |
Software: Name |
Autoprocess (XDS based automatic processing script), XDS, HKL2000, iMosflm |
AutoProcess (XDS, BEST, pointless based automatic processing script), XDS, HKL2000, iMosflm |
2010-07-02 03:46:52 |
Software: Classification |
Control/collection |
Control/collection |
2010-07-02 03:46:44 |
Software: Name |
MxDC, Autoprocess, XDS, HKL2000, iMosflm |
MxDC |
2010-07-02 03:46:14 |
Software: Name |
Autoprocess, XDS, HKL2000, iMosflm |
MxDC, Autoprocess, XDS, HKL2000, iMosflm |
2010-07-02 03:45:15 |
Flux Coefficient |
5 |
2 |
2010-07-02 03:44:47 |
Special Capabilities |
Automatic Crystal Alignment |
Automatic Crystal Alignment |
2010-07-02 03:44:17 |
Special Capabilities |
Automatic Crystal Alignment |
Automatic Crystal Alignment |
2010-07-02 03:43:52 |
Special Capabilities |
High Intensity |
Automatic Crystal Alignment |
2010-07-02 03:43:25 |
Special Capabilities |
Automatic Crystal Alignment |
High Intensity |
2010-07-02 03:43:08 |
Special Capabilities |
High Resolution |
Automatic Crystal Alignment |
2010-07-02 03:42:56 |
Special Capabilities |
Automatic Crystal Alignment |
High Resolution |
2010-07-02 03:42:30 |
Special Capabilities |
High Resolution |
Automatic Crystal Alignment |
2010-07-02 03:42:15 |
Special Capabilities |
Absorption Edges, Automatic Crystal Alignment, High Intensity, High Resolution |
High Resolution |
2010-07-02 03:41:52 |
Experiments Details |
|
|
2010-07-02 03:41:37 |
Experiments |
MAD, SAD, FLUORESCENCE |
MAD |
2010-05-18 01:43:52 |
Flux Details |
12keV photons/s (at 250 mA) |
flux measure at 12.658 keV at 250 mA |
2010-05-18 01:43:00 |
Services |
Mail-in, Rapid access |
Data collection, High quality data collection, Mail-in, Rapid access |
2010-05-18 01:42:38 |
Special Capabilities Details |
Two Theta Offset |
|
2010-05-18 01:38:59 |
Experiments |
MAD, SAD |
MAD, SAD, FLUORESCENCE |
2010-05-18 01:20:06 |
Removed from Service: Details |
Upgraded to Rayonix MX300 |
|
2010-05-18 12:10:52 |
Software: Name |
Autoprocess, XDS, HKL2000, iMosflm |
Autoprocess (XDS based automatic processing script), XDS, HKL2000, iMosflm |
2010-05-18 12:10:19 |
Hardware |
Del Precsion 360 |
Del Precsion 360 user workstations |
2010-05-18 12:09:51 |
Backup Services |
Archiver |
Automatic data archiver, DVD/Blu-Ray Robot (comming soon) |
2010-05-18 12:08:49 |
Software: Name |
Autoprocess |
Autoprocess, XDS, HKL2000, iMosflm |
2010-05-18 12:08:00 |
Software: Name |
MXDC, XDS, AutoProcss, HKL2000, IMOSFLM |
MXDC |
2010-05-18 12:07:24 |
Cryo Capability |
Oxford instruments cryoject |
Oxford Cryojet |
2010-05-18 12:07:02 |
Removed from Service: Details |
Upgraded to Rayonix MX300 |
Upgraded to Rayonix MX-300 |
2010-05-18 12:06:55 |
Removed from Service: Details |
Upgraded to Rayonix Mx300 |
Upgraded to Rayonix MX300 |
2010-05-18 12:03:07 |
Robotics: More Info |
|
SAM commissioning in progress |
2010-05-18 12:02:53 |
Sample Handling: Robotics |
|
(SAM) Stanford Automated Mounting System |
2010-05-18 12:02:36 |
Mirrors |
Vertically focusing |
Vertically focusing mirror |
2010-05-18 12:01:49 |
Mirrors |
vertically focusing |
Vertically focusing |
2010-05-18 12:01:35 |
Monochromator |
double crystal monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal |
Double Crystal Monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal |
2010-05-18 12:01:08 |
Source Details |
20 mm hybrid small gap in-vacuum undulator |
20 mm hybrid small-gap in-vacuum undulator |
2010-05-18 12:00:54 |
Services |
|
Mail-in, Rapid access |
2010-05-18 12:00:30 |
Special Capabilities |
Automatic Crystal Alignment |
Absorption Edges, Automatic Crystal Alignment, High Intensity, High Resolution |
2010-05-18 11:59:25 |
Status Details |
|
Accepting Proposals |
2010-05-17 07:05:21 |
Flux Coefficient |
3 |
5 |
2010-05-17 07:04:36 |
Detector: Activated for Service |
info currently not available |
2006-03-18 |
2010-05-17 07:02:12 |
Flux Coefficient |
1 |
3 |
2010-05-17 07:01:52 |
Spot Size (mm): Width |
0.05 |
0.13 |
2010-05-17 07:01:48 |
Spot Size (mm): Height |
0.15 |
0.05 |
2010-05-17 07:01:29 |
Source Type |
insertion device |
INSERTION DEVICE |
2010-05-17 07:01:03 |
Special Capabilities Details |
2theta offset |
Two Theta Offset |
2010-05-17 07:00:21 |
Experiments |
MAD |
MAD, SAD |
2010-05-17 06:59:53 |
%Time Available (general use) |
45 |
55 |
2010-05-17 06:59:36 |
Owner/Operator |
Canadian Macromolecular Crystallography Facility - University of Saskatchewan |
Canadian Macromolecular Crystallography Facility - Canadian Light Source, Inc. |
2010-03-22 12:06:35 |
Software: Classification |
|
Control/collection |
2010-03-22 12:06:27 |
Software: Name |
XDS & AutoProcss, HKL2000, CCP4 |
MXDC, XDS, AutoProcss, HKL2000, IMOSFLM |
2010-03-22 12:05:50 |
Software: Name |
XDS & autoxds, HKL2000, CCP4 |
XDS & AutoProcss, HKL2000, CCP4 |
2010-03-22 12:00:50 |
Detector: Activated for Service |
2006-03-18 |
2010-04-01 |
2010-03-22 11:59:50 |
Detector: Model |
MAR MOSAIC 225 |
RAYONIX MX-300 |
2010-03-22 11:59:18 |
Secondary Contact: Email |
louis.delbaere@usask.ca |
mirek@bri.nrc.ca |
2010-03-22 11:58:22 |
Secondary Contact: Name |
Louis Delbaere |
Mirek Cygler |
2009-09-09 01:38:56 |
Backup Services |
|
Archiver |
2009-09-09 01:37:43 |
Detector: Activated for Service |
2009-01-18 |
2006-03-18 |
2009-09-09 01:37:00 |
Detector: Activated for Service |
2009-09-16 |
2009-01-18 |
2009-09-09 01:34:34 |
Detector: Activated for Service |
info currently not available |
2009-09-16 |
2009-09-09 01:33:30 |
Special Capabilities Details |
|
2theta offset |
2009-09-09 01:32:59 |
Special Capabilities |
|
Automatic Crystal Alignment |
2009-09-09 01:32:17 |
Monochromator |
double crystal monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crysta |
double crystal monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal |
2009-09-09 01:31:57 |
Spot Size (mm): Height |
0.20 |
0.15 |
2009-09-09 01:31:49 |
Spot Size (mm): Width |
0.10 |
0.05 |
2009-09-09 01:31:12 |
%Time Available (general use) |
|
45 |
2009-09-09 01:30:18 |
Beamline Website |
http://ex.lightsource.ca/cmcf/ |
http://exshare.lightsource.ca/cmcf/ |