Change history for CLSI - 08ID-1

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2023-08-17 02:25:33 Hardware 128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations 128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations
2023-08-17 02:25:23 Software: Name AutoProcess (XDS, BEST, POINTLESS based automatic processing script), XDS, HKL2000, iMosflm MXproc (XDS, BEST, POINTLESS based automatic processing script), XDS, HKL2000, iMosflm
2023-08-17 02:25:01 Removed from Service: Details Upgraded to Dectris Eiger 9M
2023-08-17 02:24:31 Robotics: More Info SSRL cassette, Uni-puck Uni-puck
2023-08-17 02:24:23 Sample Handling: Robotics (SAM) Stanford Automated Mounting System Irelec ISARA Automated Sample Changer, 29 puck capacity
2023-08-17 02:23:28 Sample Handling: Manual 18 mm Hampton pin is recommended Default: 18 mm pin in magnetic Hampton/Mitegen base. Alternative: Low-profile SBS standard plates
2023-08-17 02:20:53 Goniometer Details Optional Plate Holder and Mini-Kappa attachments. Optional HC1 humidity control device
2023-08-17 02:20:07 Goniometer MD2-S (Arinax) with SmartMagnet and Plate Holder. On-axis visualization (Arinax OAV-B) MD2-S (Arinax) with SmartMagnet. On-axis visualization (Arinax OAV-B-zoom), Bruker X-flash 410 fluorescence detector, and Oxford CryoJet
2023-08-17 02:18:20 Goniometer Huber Model 410 with a single phi axis complemented with on-axis visulization system MD2-S (Arinax) with SmartMagnet and Plate Holder. On-axis visualization (Arinax OAV-B)
2023-08-17 02:16:14 Wavelength (Å): Min 0.69 0.62
2023-08-17 02:15:45 Wavelength (Å): Max 1.9 2.48
2023-08-17 02:14:32 Detector: Removed from Service 2020-05-01
2023-08-17 02:13:24 Flux Details flux measure at 12.658 keV at 250 mA Maximal flux measure at 12 keV (DCM) and 9.72 keV (DMM) at 200 mA
2023-08-17 02:12:17 Flux Exponent 12 12 (DCM) or 14 (DMM)
2023-08-17 02:11:59 Flux Coefficient 5 8.2 (DCM) or 1.2 (DMM)
2023-08-17 02:11:09 Energy Range (keV): Min 5 (DMM) or 7.2 (DCM) 5 (DCM) or 7.2 (DMM)
2023-08-17 02:10:55 Energy Range (keV): Max 18 20 (DMM) or 10.4 (DMM)
2023-08-17 02:10:39 Energy Range (keV): Min 5 5 (DMM) or 7.2 (DCM)
2023-08-17 02:10:20 Energy Range (keV): Min 6.5 5
2023-08-17 02:08:30 Mirrors Vertically focussing Si(001) mirror Elliptically bent vertical and horizontal focussing Rh/Ir coated Si(001) crystals in a Kirkpatrick-Baez configuration.
2023-08-17 02:02:26 Mirrors Vertically focusing mirror Vertically focussing Si(001) mirror
2023-08-17 02:00:59 Monochromator Double Crystal Monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal Double Crystal Multilayer Monochromator (Axilon DCMM) comprising a pair of indirectly cryo-cooled Si(111) crystals (DCM) and Bo/B4C-coated Si(111) multilayers (300 bilayers, DMM mode)
2023-08-17 01:58:32 Spot Size (mm): Width 0.15 0.005-0.05
2023-08-17 01:58:24 Spot Size (mm): Height 0.05 0.005-0.05
2023-08-17 01:52:57 %Time Available (general use) 55 65
2022-05-26 01:14:53 Detector: Model MARmosaic 225 Eiger x 9M
2022-05-26 01:14:51 Detector: Type CCD PIXEL
2022-05-26 01:11:22 Secondary Contact: Email michel.fodje@lightsource.ca
2022-05-26 01:11:15 Secondary Contact: Name Michel Fodje
2022-05-26 01:11:00 Removed from Service: Details Upgraded to Rayonix MX-300
2022-05-26 01:10:24 Detector: Activated for Service 202-05-10 2022-05-10
2022-05-26 01:10:03 Detector: Activated for Service 2006-03-18 202-05-10
2022-05-26 01:06:01 Primary Contact: Name Pawel Grochulski Michel Fodje Michel Fodje
2022-05-26 01:05:52 Primary Contact: Email pawel.grochulski@lightsource.ca michel.fodje@lightsource.ca
2022-05-26 01:05:27 Primary Contact: Name Pawel Grochulski Pawel Grochulski Michel Fodje
2017-09-26 06:13:34 Detector: Removed from Service 2017-02-03 2020-01-01
2017-09-26 06:12:04 Detector: Removed from Service 2017-02-03 2010-03-31
2017-09-26 06:09:45 Removed from Service: Details Upgraded to Dectris Pilatus 6M
2017-09-26 06:09:25 Detector: Removed from Service 2017-02-03
2011-07-05 08:46:06 Special Capabilities Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput, Humidity Control Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput
2011-07-05 08:44:04 Special Capabilities Automated Sample Screening, High Intensity, High Resolution Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput, Humidity Control
2011-07-05 08:43:07 Special Capabilities Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput Automated Sample Screening, High Intensity, High Resolution
2011-02-22 03:34:50 Flux Coefficient 2 5
2011-02-22 03:34:32 Services Details Mail-In
2011-02-22 03:34:26 Services Details Mail-In Mail-In
2011-02-22 03:34:17 Services Rapid access High quality data collection, Mail-in, Processing, Rapid access
2011-02-22 03:33:32 Special Capabilities Automatic Crystal Alignment Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Intensity, High Resolution, High Throughput
2011-02-22 03:32:46 Experiments Details S-SAD
2011-02-22 03:32:18 Experiments MAD MAD, SAD, MONOCHROMATIC, FLUORESCENCE
2010-12-02 09:01:20 Spot Size (mm): Width 0.13 0.15
2010-12-02 08:59:28 Goniometer Huber Model 410 with single phi axis and on-axis visulization system Huber Model 410 with a single phi axis complemented with on-axis visulization system
2010-12-02 08:58:27 Goniometer Huber Model 410 with single phi axis Huber Model 410 with single phi axis and on-axis visulization system
2010-09-22 11:41:55 Beamline Website http://exshare.lightsource.ca/cmcf/ http://cmcf.lightsource.ca
2010-09-16 04:12:19 Hardware 128-core SUN computing cluster with 8Tb RAID and 30 Tb of long-term storage. Precsion 360 user workstations 128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations
2010-09-16 04:11:48 Hardware 128-core SUN computing cluster with 8Tb RAID and 30 Tb of lon-term storage. Precsion 360 user workstations 128-core SUN computing cluster with 8Tb RAID and 30 Tb of long-term storage. Precsion 360 user workstations
2010-09-16 04:10:23 Hardware SUN server with 8Tb Raid system, 30 Tb backup and Del Precsion 360 user workstations 128-core SUN computing cluster with 8Tb RAID and 30 Tb of lon-term storage. Precsion 360 user workstations
2010-09-14 02:09:03 Sample Handling: Manual Any magnetic pin bases but 18 mm Hampton pin is recommended 18 mm Hampton pin is recommended
2010-09-14 02:08:29 Special Capabilities Details High flux, High flux
2010-09-14 02:08:23 Special Capabilities Details High flux,
2010-09-14 02:07:53 Special Capabilities Automatic Crystal Alignment Automatic Crystal Alignment
2010-09-14 02:07:42 Special Capabilities High Intensity Automatic Crystal Alignment
2010-09-14 02:07:22 Special Capabilities Details
2010-09-14 02:07:15 Special Capabilities Automated Sample Screening High Intensity
2010-09-14 02:07:08 Special Capabilities Automatic Crystal Alignment Automated Sample Screening
2010-09-14 02:06:51 Experiments Details S-SAD
2010-09-14 02:06:42 Experiments MAD MAD
2010-09-14 02:06:18 Services Details Mail-In
2010-09-14 02:05:40 Services Data collection, High quality data collection, Mail-in, Rapid access Rapid access
2010-09-14 02:07:52 Hardware SUN server and Del Precsion 360 user workstations SUN server with 8Tb Raid system, 30 Tb backup and Del Precsion 360 user workstations
2010-09-14 02:01:39 Hardware Del Precsion 360 user workstations SUN server and Del Precsion 360 user workstations
2010-09-14 02:01:18 Backup Services Archiver (automatic data archiver), DVD/Blu-Ray Robot Archiver for external USB disks, DVD/Blu-Ray Robot
2010-09-14 01:59:01 Sample Handling: Manual Any magnetic pin bases but 18 mm Hampton pin is recomended Any magnetic pin bases but 18 mm Hampton pin is recommended
2010-09-14 01:57:06 Sample Handling: Manual Prefered 18 mm Hampton CRYOPIN Any magnetic pin bases but 18 mm Hampton pin is recomended
2010-09-14 01:53:38 Sample Handling: Manual 18 mm Hampton CRYOPIN Prefered 18 mm Hampton CRYOPIN
2010-09-14 01:51:19 Robotics: More Info SAM commissioning in progress SSRL cassette, Uni-puck
2010-09-14 01:48:12 Sample Handling: Manual 18 mm Hampton CRYOPIN 18 mm Hampton CRYOPIN
2010-09-14 01:46:27 Status operational Operational
2010-09-13 06:11:42 Secondary Contact: Email michel.fodje@lightsource.ca.ca michel.fodje@lightsource.ca
2010-09-13 06:11:29 Secondary Contact: Email mirek@bri.nrc.ca michel.fodje@lightsource.ca.ca
2010-09-13 06:11:09 Secondary Contact: Name Pawel Grochulski Michel Fodje
2010-09-13 06:10:44 Secondary Contact: Name Mirek Cygler Pawel Grochulski
2010-09-13 02:12:31 Backup Services Automatic data archiver, DVD/Blu-Ray Robot (comming soon) Archiver (automatic data archiver), DVD/Blu-Ray Robot
2010-09-13 02:11:23 Software: Name CCP4, COOT, PHENIX CCP4, PHENIX, COOT
2010-07-02 03:48:45 Software: Name CCP4 CCP4, COOT, PHENIX
2010-07-02 03:48:09 Software: Name AutoProcess (XDS, BEST, pointless based automatic processing script), XDS, HKL2000, iMosflm AutoProcess (XDS, BEST, POINTLESS based automatic processing script), XDS, HKL2000, iMosflm
2010-07-02 03:47:48 Software: Name Autoprocess (XDS based automatic processing script), XDS, HKL2000, iMosflm AutoProcess (XDS, BEST, pointless based automatic processing script), XDS, HKL2000, iMosflm
2010-07-02 03:46:52 Software: Classification Control/collection Control/collection
2010-07-02 03:46:44 Software: Name MxDC, Autoprocess, XDS, HKL2000, iMosflm MxDC
2010-07-02 03:46:14 Software: Name Autoprocess, XDS, HKL2000, iMosflm MxDC, Autoprocess, XDS, HKL2000, iMosflm
2010-07-02 03:45:15 Flux Coefficient 5 2
2010-07-02 03:44:47 Special Capabilities Automatic Crystal Alignment Automatic Crystal Alignment
2010-07-02 03:44:17 Special Capabilities Automatic Crystal Alignment Automatic Crystal Alignment
2010-07-02 03:43:52 Special Capabilities High Intensity Automatic Crystal Alignment
2010-07-02 03:43:25 Special Capabilities Automatic Crystal Alignment High Intensity
2010-07-02 03:43:08 Special Capabilities High Resolution Automatic Crystal Alignment
2010-07-02 03:42:56 Special Capabilities Automatic Crystal Alignment High Resolution
2010-07-02 03:42:30 Special Capabilities High Resolution Automatic Crystal Alignment
2010-07-02 03:42:15 Special Capabilities Absorption Edges, Automatic Crystal Alignment, High Intensity, High Resolution High Resolution
2010-07-02 03:41:52 Experiments Details
2010-07-02 03:41:37 Experiments MAD, SAD, FLUORESCENCE MAD
2010-05-18 01:43:52 Flux Details 12keV photons/s (at 250 mA) flux measure at 12.658 keV at 250 mA
2010-05-18 01:43:00 Services Mail-in, Rapid access Data collection, High quality data collection, Mail-in, Rapid access
2010-05-18 01:42:38 Special Capabilities Details Two Theta Offset
2010-05-18 01:38:59 Experiments MAD, SAD MAD, SAD, FLUORESCENCE
2010-05-18 01:20:06 Removed from Service: Details Upgraded to Rayonix MX300
2010-05-18 12:10:52 Software: Name Autoprocess, XDS, HKL2000, iMosflm Autoprocess (XDS based automatic processing script), XDS, HKL2000, iMosflm
2010-05-18 12:10:19 Hardware Del Precsion 360 Del Precsion 360 user workstations
2010-05-18 12:09:51 Backup Services Archiver Automatic data archiver, DVD/Blu-Ray Robot (comming soon)
2010-05-18 12:08:49 Software: Name Autoprocess Autoprocess, XDS, HKL2000, iMosflm
2010-05-18 12:08:00 Software: Name MXDC, XDS, AutoProcss, HKL2000, IMOSFLM MXDC
2010-05-18 12:07:24 Cryo Capability Oxford instruments cryoject Oxford Cryojet
2010-05-18 12:07:02 Removed from Service: Details Upgraded to Rayonix MX300 Upgraded to Rayonix MX-300
2010-05-18 12:06:55 Removed from Service: Details Upgraded to Rayonix Mx300 Upgraded to Rayonix MX300
2010-05-18 12:03:07 Robotics: More Info SAM commissioning in progress
2010-05-18 12:02:53 Sample Handling: Robotics (SAM) Stanford Automated Mounting System
2010-05-18 12:02:36 Mirrors Vertically focusing Vertically focusing mirror
2010-05-18 12:01:49 Mirrors vertically focusing Vertically focusing
2010-05-18 12:01:35 Monochromator double crystal monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal Double Crystal Monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal
2010-05-18 12:01:08 Source Details 20 mm hybrid small gap in-vacuum undulator 20 mm hybrid small-gap in-vacuum undulator
2010-05-18 12:00:54 Services Mail-in, Rapid access
2010-05-18 12:00:30 Special Capabilities Automatic Crystal Alignment Absorption Edges, Automatic Crystal Alignment, High Intensity, High Resolution
2010-05-18 11:59:25 Status Details Accepting Proposals
2010-05-17 07:05:21 Flux Coefficient 3 5
2010-05-17 07:04:36 Detector: Activated for Service info currently not available 2006-03-18
2010-05-17 07:02:12 Flux Coefficient 1 3
2010-05-17 07:01:52 Spot Size (mm): Width 0.05 0.13
2010-05-17 07:01:48 Spot Size (mm): Height 0.15 0.05
2010-05-17 07:01:29 Source Type insertion device INSERTION DEVICE
2010-05-17 07:01:03 Special Capabilities Details 2theta offset Two Theta Offset
2010-05-17 07:00:21 Experiments MAD MAD, SAD
2010-05-17 06:59:53 %Time Available (general use) 45 55
2010-05-17 06:59:36 Owner/Operator Canadian Macromolecular Crystallography Facility - University of Saskatchewan Canadian Macromolecular Crystallography Facility - Canadian Light Source, Inc.
2010-03-22 12:06:35 Software: Classification Control/collection
2010-03-22 12:06:27 Software: Name XDS & AutoProcss, HKL2000, CCP4 MXDC, XDS, AutoProcss, HKL2000, IMOSFLM
2010-03-22 12:05:50 Software: Name XDS & autoxds, HKL2000, CCP4 XDS & AutoProcss, HKL2000, CCP4
2010-03-22 12:00:50 Detector: Activated for Service 2006-03-18 2010-04-01
2010-03-22 11:59:50 Detector: Model MAR MOSAIC 225 RAYONIX MX-300
2010-03-22 11:59:18 Secondary Contact: Email louis.delbaere@usask.ca mirek@bri.nrc.ca
2010-03-22 11:58:22 Secondary Contact: Name Louis Delbaere Mirek Cygler
2009-09-09 01:38:56 Backup Services Archiver
2009-09-09 01:37:43 Detector: Activated for Service 2009-01-18 2006-03-18
2009-09-09 01:37:00 Detector: Activated for Service 2009-09-16 2009-01-18
2009-09-09 01:34:34 Detector: Activated for Service info currently not available 2009-09-16
2009-09-09 01:33:30 Special Capabilities Details 2theta offset
2009-09-09 01:32:59 Special Capabilities Automatic Crystal Alignment
2009-09-09 01:32:17 Monochromator double crystal monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crysta double crystal monochromator (ACCEL DCM) with an indirectly cryo-cooled first crystal and sagittally focusing second crystal
2009-09-09 01:31:57 Spot Size (mm): Height 0.20 0.15
2009-09-09 01:31:49 Spot Size (mm): Width 0.10 0.05
2009-09-09 01:31:12 %Time Available (general use) 45
2009-09-09 01:30:18 Beamline Website http://ex.lightsource.ca/cmcf/ http://exshare.lightsource.ca/cmcf/