2023-08-17 02:45:06 |
Wavelength (Å): Min |
0.69 (DCM) or 1.18 (DMM) |
0.69 |
2023-08-17 02:45:00 |
Wavelength (Å): Max |
2.07 (DCM) or 1.77 (DMM) |
2.07 |
2023-08-17 02:43:56 |
Software: Name |
XDS, AutoProcss, HKL2000, IMOSFLM |
XDS, MXproc, HKL2000, IMOSFLM |
2023-08-17 02:43:39 |
Sample Handling: Manual |
|
18 mm pins in Hampton/Mitegen magnetic bases required |
2023-08-17 02:42:59 |
Goniometer Details |
mini Kappa |
Default permanent magnet. Optional mini Kappa |
2023-08-17 02:42:31 |
Goniometer |
ACCEL MD2 microdiffractometer |
Arinax MD2 microdiffractometer |
2023-08-17 02:42:16 |
Wavelength (Å): Min |
0.62 (DCM) or 1.18 (DMM) |
0.69 (DCM) or 1.18 (DMM) |
2023-08-17 02:41:59 |
Wavelength (Å): Max |
2.48 (DCM) or 1.77 (DMM) |
2.07 (DCM) or 1.77 (DMM) |
2023-08-17 02:41:44 |
Energy Range (keV): Max |
18 |
18 (DCM) or 10.5 (DMM) |
2023-08-17 02:41:31 |
Energy Range (keV): Min |
4 |
6 (DCM) or 7 (DMM) |
2023-08-17 02:40:57 |
Wavelength (Å): Max |
2.48 |
2.48 (DCM) or 1.77 (DMM) |
2023-08-17 02:40:37 |
Wavelength (Å): Min |
0.62 (DCM) or |
0.62 (DCM) or 1.18 (DMM) |
2023-08-17 02:40:10 |
Wavelength (Å): Min |
0.62 |
0.62 (DCM) or |
2023-08-17 02:39:34 |
Wavelength (Å): Min |
0.69 |
0.62 |
2023-08-17 02:39:14 |
Wavelength (Å): Max |
3.1 |
2.48 |
2023-08-17 02:38:43 |
Flux Details |
@ 12 keV |
At maximal flux measured at 12.0 keV (DCM) and 8.157 kev (DMM), 220 mA |
2023-08-17 02:37:45 |
Flux Exponent |
11 |
11 (DCM) or 2.5 (DMM) |
2023-08-17 02:37:30 |
Flux Coefficient |
1 |
1.5 (DCM) or 3.7 (DMM) |
2023-08-17 02:36:50 |
Crystal Type |
|
Si(111) (DCM) 500 bilayer coated Si(111) multilayer |
2023-08-17 02:36:10 |
Monochromator |
Kohzu double crystal indirectly water cooled first crystal or double-multilayer |
Kohzu double crystal indirectly water cooled first crystal with flat second crystal (DCM) or double-multilayer (DMM) |
2023-08-17 02:35:44 |
Monochromator |
double crystal indirectly water cooled first crystal or double-multilayer |
Kohzu double crystal indirectly water cooled first crystal or double-multilayer |
2023-08-17 02:35:11 |
Spot Size (mm): Width |
.19 |
0.2-0.02 |
2023-08-17 02:35:01 |
Spot Size (mm): Height |
.21 |
0.2-0.02 |
2023-08-17 02:34:01 |
Experiments Details |
Designed for complmentary performance to the existing CMCF 08ID-1 beamline, the 08B1-1 beamline is used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
Designed for complmentary performance to the existing CMCF 08ID-1 beamline, the 08B1-1 beamline is used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
2023-08-17 02:33:47 |
Experiments Details |
Designed for complmentary performance to the existing CMCF 08ID-1 bealmine, the 08B1-1 beamline is used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
Designed for complmentary performance to the existing CMCF 08ID-1 beamline, the 08B1-1 beamline is used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
2023-08-17 02:33:17 |
%Time Available (general use) |
55 |
65 |
2023-08-17 02:33:12 |
Status |
Operational |
Operational |
2023-08-17 02:33:08 |
Status Details |
|
Accepting proposals |
2023-08-17 02:30:23 |
Detector: Activated for Service |
2020-01-05 |
2015-08-25 |
2023-08-17 02:29:48 |
Removed from Service: Details |
|
Upgraded to Dectris Pilatus 6M |
2023-08-17 02:29:28 |
Detector: Removed from Service |
|
2020-05-31 |
2022-05-26 01:04:16 |
Secondary Contact: Email |
pawel.grochulski@lightsource.ca |
|
2022-05-26 01:03:45 |
Detector: Activated for Service |
2010-03-01 |
2020-01-05 |
2022-05-26 01:02:23 |
Detector: Details |
300HE |
|
2022-05-26 01:00:51 |
Monochromator |
double crystal indirectly water cooled first crystal or multiliers |
double crystal indirectly water cooled first crystal or double-multilayer |
2022-05-26 12:58:09 |
Monochromator |
double crystal indirectly water cooled first crystal |
double crystal indirectly water cooled first crystal or multiliers |
2022-05-26 12:56:37 |
Secondary Contact: Name |
Pawel Grochulski |
|
2011-07-05 08:49:29 |
Special Capabilities Details |
|
The HC1 humidity control instrument allows the user to control the relative humidity surrounding a crystal by delivering a precisely calibrated air stream |
2011-07-05 08:47:15 |
Special Capabilities |
Automatic Crystal Alignment, Automated Sample Screening, High Throughput, Long Wavelength |
Automatic Crystal Alignment, Automated Sample Screening, High Throughput, Humidity Control, Long Wavelength |
2011-02-22 03:43:02 |
Hardware |
Backup hardware:DVD/Blu-ray |
128-core SUN computing cluster with 8Tb RAID and 30Tb of long-term storage. Precsion 360 user workstations |
2011-02-22 03:42:32 |
Backup Services |
"Archiver" for external USB disks, VD/Blu-Ray robot |
"Archiver" for external USB disks, DVD/Blu-Ray robot |
2011-02-22 03:42:21 |
Backup Services |
"Archiver" for external USB disks ,DVD/Blu-Ray robot |
"Archiver" for external USB disks, VD/Blu-Ray robot |
2011-02-22 03:42:06 |
Backup Services |
USB disks using "Archiver" script |
"Archiver" for external USB disks ,DVD/Blu-Ray robot |
2011-02-22 03:41:06 |
Lab Facilities |
|
NORMAL |
2011-02-22 03:40:39 |
Robotics: More Info |
Uni-pucks and SSRL cassettes |
Uni-pucks and SSRL cassettes using 18 mm pins |
2011-02-22 03:40:14 |
Robotics: More Info |
|
Uni-pucks and SSRL cassettes |
2011-02-22 03:39:27 |
Special Capabilities Details |
EXAFS |
|
2011-02-22 03:39:09 |
Experiments |
XAFS, EXAFS, FLUORESCENCE |
MAD, SAD, MONOCHROMATIC, EXAFS, FLUORESCENCE |
2011-02-22 03:38:13 |
Experiments |
MAD |
XAFS, EXAFS, FLUORESCENCE |
2011-02-22 03:31:06 |
Backup Services |
USB disks with Archiver script |
USB disks using "Archiver" script |
2011-02-22 03:30:35 |
Backup Services |
|
USB disks with Archiver script |
2011-02-22 03:30:07 |
Hardware |
Backuo hardware:DVD/Blu-ray |
Backup hardware:DVD/Blu-ray |
2011-02-22 03:29:54 |
Hardware |
DVD/Blu-ray |
Backuo hardware:DVD/Blu-ray |
2011-02-22 03:29:04 |
Hardware |
|
DVD/Blu-ray |
2011-02-22 03:27:35 |
Detector: Details |
|
300HE |
2011-02-22 03:26:49 |
Goniometer Details |
|
mini Kappa |
2011-02-22 03:26:14 |
Spot Size (mm): Width |
.16 |
.19 |
2011-02-22 03:26:05 |
Spot Size (mm): Height |
.23 |
.21 |
2011-02-22 03:25:38 |
Services |
Mail-in, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution |
Data collection, High quality data collection, Mail-in, Processing, Rapid access |
2011-02-22 03:24:50 |
Services |
Structure solution |
Mail-in, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution |
2011-02-22 03:24:19 |
Services |
Structure solution |
Structure solution |
2011-02-22 03:24:13 |
Services |
Structure solution |
Structure solution |
2011-02-22 03:23:56 |
Services |
|
Structure solution |
2011-02-22 03:23:47 |
Special Capabilities Details |
|
EXAFS |
2011-02-22 03:23:25 |
Special Capabilities |
Automatic Crystal Alignment |
Automatic Crystal Alignment, Automated Sample Screening, High Throughput, Long Wavelength |
2011-02-22 03:22:33 |
Special Capabilities |
|
Automatic Crystal Alignment |
2011-02-22 03:22:13 |
%Time Available (general use) |
|
55 |
2011-02-22 03:21:58 |
Status |
Commissioning |
Operational |
2010-12-02 08:55:12 |
Sample Handling: Robotics |
|
(SAM) Stanford Automated Mounting System |
2010-12-02 08:54:30 |
Experiments Details |
Designed for complmentary performance to the existing CMCF 08ID-1 bealmine, the 08B1-1 beamline will be used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
Designed for complmentary performance to the existing CMCF 08ID-1 bealmine, the 08B1-1 beamline is used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
2010-09-22 11:43:51 |
Beamline Website |
http://exshare.lightsource.ca/cmcf/ |
http://cmcf.lightsource.ca |
2010-09-13 06:13:00 |
Beamline Website |
http://www.lightsource.ca/experimental/cmcf_2.php |
http://exshare.lightsource.ca/cmcf/ |
2010-09-13 06:12:47 |
Secondary Contact: Email |
natalie@byron.biochem.ubc.ca |
pawel.grochulski@lightsource.ca |
2010-09-13 06:12:26 |
Secondary Contact: Name |
Natalie Strynadka |
Pawel Grochulski |
2010-07-02 03:52:55 |
Software: Classification |
Control/collection |
Processing |
2010-07-02 03:52:42 |
Software: Classification |
|
Control/collection |
2010-05-18 11:58:30 |
Owner/Operator |
Canadian Macromolecular Crystallography Facility - University of Saskatchewan |
Canadian Macromolecular Crystallography Facility - Canadian Light Source, Inc. |
2010-05-14 06:57:11 |
Software: Name |
MXDC |
XDS, AutoProcss, HKL2000, IMOSFLM |
2010-05-14 06:54:31 |
Detector: Activated for Service |
info currently not available |
2010-03-01 |
2010-05-14 06:54:04 |
Detector: Model |
RAYONIX MX-300 |
RAYONIX MX-300 |
2010-05-14 06:53:42 |
Flux Exponent |
12 |
11 |
2010-05-14 06:53:21 |
Experiments Details |
Designed for complmentary performance to the existing CMCF 08ID-1 bealmine, the 08B1 beamline will be used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
Designed for complmentary performance to the existing CMCF 08ID-1 bealmine, the 08B1-1 beamline will be used for screening crystals and for high-throughput crystallographic analysis of well-ordered crystals |
2010-03-22 12:04:43 |
Software: Name |
MDC |
MXDC |
2010-03-22 12:03:51 |
Status |
Under construction |
Commissioning |
2010-03-22 12:03:31 |
Primary Contact: Name |
Michael Fodje |
Michel Fodje |
2010-03-22 12:02:07 |
Detector: Model |
MARmosaic 300 |
RAYONIX MX-300 |
2009-09-09 01:40:59 |
Owner/Operator |
CMCF (Canadian Macromolecular Crystallography Facility) |
Canadian Macromolecular Crystallography Facility - University of Saskatchewan |