2020-03-08 11:03:52 |
Status |
Operational |
Decommissioned |
2016-10-12 09:08:38 |
Removed from Service: Details |
replaced by Pilatus, available as a spare |
|
2016-10-12 09:07:58 |
Experiments Details |
The energy (19.3 keV) at this station is fixed. |
Two fixed energies, 19.6 and 32.5 keV |
2016-10-12 09:06:44 |
Wavelength (Å): Min |
0.63 |
0.38 |
2016-10-12 09:06:07 |
Energy Range (keV): Max |
19.3 |
32.5 |
2016-10-12 09:05:37 |
Wavelength (Å): Max |
0.64 |
0.63 |
2016-10-12 09:05:28 |
Wavelength (Å): Min |
0.64 |
0.63 |
2016-10-12 09:04:32 |
Energy Range (keV): Min |
19.3 |
19.6 |
2016-10-12 09:04:11 |
Robotics: More Info |
accepts MSC pucks, Unipucks, Rigaku pucks |
|
2016-10-12 09:03:53 |
Sample Handling: Robotics |
BAM2(second generation Berkeley automated mounting system) |
None |
2016-10-12 09:01:28 |
%Time Available (general use) |
100 |
20 |
2016-10-12 09:01:12 |
Status |
Undergoing upgrade |
Operational |
2014-09-29 03:23:55 |
Source Details |
CHESS Compact Undulator |
Cornell Compact Undulator |
2014-09-29 03:06:13 |
Software: Name |
HKL2000, DPS/Mosflm, XDS |
HKL2000, Mosflm, XDS |
2014-09-29 02:58:31 |
Removed from Service: Details |
|
replaced by Pilatus, available as a spare |
2014-09-29 02:57:41 |
Detector: Removed from Service |
|
2014-09-01 |
2014-09-29 02:55:57 |
Status |
operational |
Undergoing upgrade |
2014-09-29 02:55:40 |
Spot Size (mm): Width |
|
0.1 |
2014-09-29 02:55:35 |
Spot Size (mm): Height |
|
0.1 |
2014-09-29 02:55:17 |
Spot Size (mm): Height |
0.2 |
|
2014-09-29 02:55:10 |
Spot Size (mm): Width |
1.0 |
|
2014-09-29 02:54:59 |
Flux Coefficient |
5.0 |
|
2014-09-29 02:54:53 |
Flux Exponent |
13 |
|
2014-09-29 02:54:19 |
Experiments |
SAD, MONOCHROMATIC |
MONOCHROMATIC |
2014-09-29 02:53:11 |
Flux Details |
7.5x10^11 thru 200m collimator |
|
2014-09-29 02:51:36 |
Software: Name |
HKL2000, DPS/Mosflm |
HKL2000, DPS/Mosflm, XDS |
2014-09-29 02:50:41 |
Services Details |
Mail-in available |
Mail-in and remote data collection available |
2014-09-29 02:50:10 |
Robotics: More Info |
|
accepts MSC pucks, Unipucks, Rigaku pucks |
2014-09-29 02:49:36 |
Robotics: More Info |
The BAM2 robot is installed and will be tested in fall of 2011 - probably available to users in the spring of 2012 |
|
2014-09-29 02:49:11 |
Energy Range (keV): Max |
12.68 |
19.3 |
2014-09-29 02:49:00 |
Energy Range (keV): Min |
12.68 |
19.3 |
2014-09-29 02:48:34 |
Wavelength (Å): Max |
0.987 |
0.64 |
2014-09-29 02:48:24 |
Wavelength (Å): Min |
0.987 |
0.64 |
2014-09-29 02:47:57 |
Monochromator |
diamond Laue |
Laue single crystal |
2014-09-29 02:47:41 |
Crystal Type |
Si (111) |
diamond |
2014-09-29 02:47:25 |
Monochromator |
horizontal focusing |
diamond Laue |
2014-09-29 02:46:45 |
Source Details |
49-pole west wiggler, 0.6 mrad |
CHESS Compact Undulator |
2014-09-29 02:46:21 |
Experiments Details |
The energy (12.68 keV) at this station is fixed and slightly above Se peak for SAD data collection. Energy Resolution: ~20ev (at mono energy of 12.68 keV). |
The energy (19.3 keV) at this station is fixed. |
2014-09-29 02:44:45 |
Secondary Contact: Email |
djs63@cornell.edu |
dms35@cornell.edu |
2014-09-29 02:44:34 |
Secondary Contact: Name |
David Schuller |
Marian Szebenyi |
2014-09-29 02:44:20 |
Primary Contact: Email |
reg8@cornell.edu |
djs638@cornell.edu |
2014-09-29 02:44:05 |
Primary Contact: Name |
Richard Gillilan |
David Schuller |
2011-10-11 11:30:05 |
Sample Handling: Robotics |
|
BAM2(second generation Berkeley automated mounting system) |
2011-10-11 11:29:51 |
Robotics: More Info |
|
The BAM2 robot is installed and will be tested in fall of 2011 - probably available to users in the spring of 2012 |
2011-05-19 08:39:45 |
Beamline Website |
http://www.macchess.cornell.edu/MacCHESS-2009/a1_summary.html |
http://www.chess.cornell.edu/chess/west/A1.htm |
2009-08-24 04:30:58 |
Cryo Capability Details |
The temperature is usually set to 100 K, but can be varied from 80 K to 400 K. |
Programmable 80 to 400 K. Usually set to 100 K. |
2009-08-10 04:25:40 |
Experiments Details |
The energy (12.68 keV) at this station is fixed and slightly above Se peak for SAD data collection. Energy Resolution: ~20ev (at mono energy of 13.1 keV). |
The energy (12.68 keV) at this station is fixed and slightly above Se peak for SAD data collection. Energy Resolution: ~20ev (at mono energy of 12.68 keV). |
2009-08-10 02:57:54 |
Source Details |
49-pole west wiggler |
49-pole west wiggler, 0.6 mrad |
2009-08-10 02:57:36 |
Source Type |
bending magnet |
INSERTION DEVICE |
2009-08-10 02:56:49 |
Experiments Details |
The energy (13.1 keV) at this station is fixed and slightly above Se peak for SAD data collection. Energy Resolution: ~20ev (at mono energy of 13.1 keV). |
The energy (12.68 keV) at this station is fixed and slightly above Se peak for SAD data collection. Energy Resolution: ~20ev (at mono energy of 13.1 keV). |
2009-08-10 01:58:18 |
Detector: Activated for Service |
2001-01-03 |
2001-12-01 |
2009-08-10 01:46:37 |
Detector: Activated for Service |
info currently not available |
2001-01-03 |
2009-08-10 12:59:39 |
Software: Name |
ADX package from ADSC for CCD and overall control; rspec and spec for other hardware control; http://www.macchess.cornell.edu/MacCHESS-2006/crystallography_software.html |
ADX package from ADSC for CCD and overall control; rspec and spec for other hardware control; http://www.macchess.cornell.edu/MacCHESS-2009/crystallography_software.html |
2009-08-10 12:59:07 |
Backup Services |
Users are welcome to bring their own laptop or other computers to CHESS for data processing and backup. USB and FireWire external drives can be connected to beamline computers. |
Wired and wireless connections for user laptops. Ports for USB and FireWire external drives. SFTP to outside computers available. |
2009-08-10 12:47:20 |
Cryo Capability Details |
he temperature is usually set to 100 K, but can be varied from 80 K to 400 K. |
The temperature is usually set to 100 K, but can be varied from 80 K to 400 K. |
2009-08-10 12:47:03 |
Hardware |
Linux computers for data collection, data processing, automatic crystal centering, backup and for station. hardware control. |
Linux computers for data collection, data processing, automatic crystal centering, backup and for station hardware control. |
2009-08-10 12:45:20 |
Backup Services |
Users are welcome to bring their own laptop or other computers to CHESS for data processing and backup. IP addresses can be set up easily with DHCP, and static addresses are also available. MacCHE |
Users are welcome to bring their own laptop or other computers to CHESS for data processing and backup. USB and FireWire external drives can be connected to beamline computers. |
2009-08-10 12:42:51 |
Software: Classification |
|
Control/collection |
2009-08-10 12:37:58 |
Services Details |
|
Mail-in available |
2009-08-10 12:37:18 |
Services |
|
High quality data collection |
2009-08-10 12:35:54 |
Beamline Website |
http://www.macchess.cornell.edu/MacCHESS-2006/a1_summary.html |
http://www.macchess.cornell.edu/MacCHESS-2009/a1_summary.html |
2009-08-10 12:35:03 |
Primary Contact: Name |
Richard Gillian |
Richard Gillilan |