Facility Data Managers Login Here

New User? | Forgot Password?

SOLEIL - PROXIMA 2

Edit this PROXIMA 2 View change history for PROXIMA 2

Beamline Name PROXIMA 2
Primary Contact: NameWilliam Shepard
Owner/OperatorSynchrotron SOLEIL
StatusOperational
%Time Available (general use)65
ExperimentsMAD, SAD
Experiments DetailsMicro-focus beamline, energy tunable, X-ray fluorescence, grid scans & helical scans
Source TypeINSERTION DEVICE
Source Detailsin vacuum U24
Spot Size (mm): Height0.005 FWHM
Spot Size (mm): Width0.010 FWHM
Monochromatorchannel cut cryogenically cooled monochromator crystal
Crystal TypeSi[111]
MirrorsKirkpatrick-Baez pair of bi-morph mirrors
Flux(PHOTONS/SEC)1.0 x 10^12
Flux Details@ 12.65 keV
Wavelength Range (Å)2.48 - 0.847
Energy Range (keV)5 - 15
Goniometersingle axis
Goniometer Detailsmicrodiffractometer MD2
Sample Handling: Manualmagnetic mounts, SPINE standard, 22 mm length, other lengths possible upon demand
Sample Handling: Robotics(CATS) Cryogenic Auto Transfer System
Robotics: More InfoDewar capicity for 9 uni-pucks
Detector: TypeCCD
Detector: ModelADSC Quantum 315r
Detector: Activated for Serviceinfo currently not available
Detector: Removed from Service
Cryo CapabilityOxford Cryosystems cryostream
Lab FacilitiesNORMAL
Backup Servicessynchrosync & USB external HDD