Facility Data Managers Login Here

New User? | Forgot Password?

Edit this BL-1A View change history for BL-1A

Beamline Name BL-1A
Primary Contact: NameNaohiro Matsugaki
Owner/OperatorSBRC
StatusOperational
%Time Available (general use)60
ExperimentsMONOCHROMATIC
Experiments DetailsNative SAD at around 3 A or MAD/SAD at around 1 A under complete helium environment
Special CapabilitiesLong Wavelength
Special Capabilities Detailsavailable long wavelength from 2.7 to 3.3 A
Source TypeINSERTION DEVICE
Source DetailsShort-gap undulator
Spot Size (mm): Height0.013
Spot Size (mm): Width0.013
Monochromatorcryocooled channel-cut
Crystal TypeSi (111)
MirrorsKB, ellipsoidal, Rh/SiO2
Flux(PHOTONS/SEC)9 x 10^10
Flux Detailsat 1.1 angstrom
Wavelength Range (Å)0.96 - 3.3
Energy Range (keV)3.7 - 12.8
Goniometersingle axis with a mini-kappa goniometer
Sample Handling: ManualHampton copper magnetic or its compatibles of 18mm length
Sample Handling: RoboticsPAM-HC: PF automounter for heilium chamber
Robotics: More InfoHampton pins in Unipucks are available
Detector: TypePIXEL
Detector: ModelDECTRIS EIGER X4M
Detector: Detailstwo EIGER detetors in V-shape configuration (optional)
Detector: Activated for Service2015-05-16
Detector: Removed from Service2015-04-16
Removed from Service: DetailsDECTRIS PILATUS 2M-F was removed
Cryo CapabilityCryoIndustry G2b-LT
Cryo Capability Details100K Helium
Lab FacilitiesNORMAL
Backup Servicesportable HDD (USB)