Primary Contact: Name | Wuxian Shi |
Secondary Contact: Name | Erik Farquhar |
Owner/Operator | Sloan-Kettering Institute, Rockefeller University, Case Western Reserve University |
Status | This beamline was shut down September 30, 2014 |
Status Details | This beamline was shut down on September 30, 2014 |
%Time Available (general use) | 25 |
Experiments | MAD |
Source Type | bending magnet |
Spot Size (mm): Height | 0.6 |
Spot Size (mm): Width | 0.1 |
Monochromator | Double flat crystal monochromator |
Crystal Type | Si 111 or Si(220) |
Mirrors | Cylindrically bent ULE mirror with Pt and Rh coating. |
Flux(PHOTONS/SEC) | 3.8 x 10^10 |
Flux Details | Flux measured in 2006 through a 0.2mm square aperture, 300mA current, energy =12658eV |
Wavelength Range (Å) | 0.84 - 1.85 |
Energy Range (keV) | 4.6 - 15 |
Goniometer | MAR rotation goniostat |
Detector: Type | CCD |
Detector: Model | MAR 165mm |
Detector: Activated for Service | info currently not available |
Detector: Removed from Service | |
Cryo Capability | Oxford |
Lab Facilities | basic users lab, Microscope and coldroom available |
Software: Name | MarCCD software, ADX,HKL2000 and many crystallographic softwares (HKL2MAP, SHELX suite, SOLVE/RESOLVE, CCP4, COOT, PyMol, Xfit). |
Software: Classification | |
Hardware | SGI Octane R12000, LINUX Dual P750 and WinPC |
Backup Services | Robotic DVD burner. External Hard Drive. CD writer. 4mm DAT tape |