Beamline Name I711
Primary Contact: NameYngve Cerenius
Owner/OperatorMax-Lab at Lund University
StatusDecommissioned
%Time Available (general use)100
ExperimentsMAD, SAXS, POWDER
Experiments DetailsThe beamline has a single crystal monochromator which provides a high photon flux at the sample while sacrificing easy tunability and high energy resolution. The experimental area is designed to have high flexibility for arranging different experimental set-ups and for easy exchange between different area and position sensitive detectors.
Source Details13-period, 1.8 T, multipole-wiggle
Spot Size (mm): Height0.3
Spot Size (mm): Width0.3
MonochromatorTriangular single crystal with horizontal diffraction plane
Crystal TypeSi (111)
MirrorsVertically focusing Pt coated Si Mirror - bendable for horizontal focusing
Flux(PHOTONS/SEC)1 x 10^11
Flux Detailsphotons/(sec 0.1% band width).calculated -> 1011 photons/sec for wavelenghts > 1 Å, behind slits 0.3 x 0.3 mm2. The additional 3 slit collimation of the incoming X-ray beam reduces the intensity to 1010 photons/sec for the SAXS experiments.
Wavelength Range (Å)0.81 - 1.55
Energy Range (keV)8.0 - 14.6
1. Detector: TypeCCD
1. Detector: ModelBRUKER SMART 1000
1. Detector: Detailsdetector for macromolecular crystallography mounted on a Mardtb baseplate. It has also successfully been used for powder diffraction experiments together with the Fit2D software.
1. Detector: Activated for Serviceinfo currently not available
1. Detector: Removed from Service
2. Detector: TypeIMAGE FOIL
2. Detector: ModelHUBER 670
2. Detector: Detailswith both a flat specimen and capillary holder as well as furnace is used for powder diffraction experiments.
2. Detector: Activated for Serviceinfo currently not available
2. Detector: Removed from Service
3. Detector: TypeCCD
3. Detector: ModelBRUKER SMART 1000
3. Detector: Detailsas back-up - equipped with an extended base with a maximum crystal to detector distance of 770 mm.
3. Detector: Activated for Serviceinfo currently not available
3. Detector: Removed from Service
4. Detector: TypeCCD
4. Detector: ModelBRUKER SMART 1000
4. Detector: Detailsith 90 mm diameter active area and 1024*10124 pixels is mounted on a three circle fixed chi goniometer. The system is equipped with a rotary shutter, collimators down to 50 micron and software packages for on-site analysis of both powder and single crystal data.
4. Detector: Activated for Serviceinfo currently not available
4. Detector: Removed from Service
Cryo CapabilityOxford instruments cryoject and cryostream
Lab Facilitieswax melter, liquid nitrogen and microscopes
Software: NameAutomar, HKL2000,Mosflm, XDS, CCP4, O, USF, X-PLOR, Bruker package for SMART 1K
Software: Classification
HardwaremLinux stations and Irix station for processing the data acquired on the marccd detector, one Windows machine in the computer room for processing the data from the SMART and Huber detectors
Backup ServicesDAT tapes, CD/DVD, firewire