Facility Data Managers Login Here

New User? | Forgot Password?

APS - 24-ID-E

Edit this 24-ID-E View change history for 24-ID-E

Beamline Name 24-ID-E
Primary Contact: NameRaj Rajashankar
Secondary Contact: NameMalcom Capel
Owner/OperatorNE-CAT
Statusoperational
%Time Available (general use)50
ExperimentsSAD
Experiments DetailsThe beamline is optimized to address challenging cases in macromolecular crystallography such as large complex molecular assemblies, poorly diffracting crystals and microcrystals by providing extremely stable and intense x-ray beams with beam sizes ranging from 5 to 70 microns.
Special CapabilitiesMicrodiffraction
Special Capabilities DetailsSe-SAD data collection - Microbeams of size 5, 20, 50 and 100 microns are achived by use of beam shaping apertures.
Source Typeinsertion device
Source Detailsinboard-projecting down-stream undulator
Spot Size (mm): Height0.120
Spot Size (mm): Width0.020
MonochromatorCryogenically-cooled single crystal
Optics DetailsCryogenically-cooled single crystal Si(220) side bounce monochromator. Optional Si(311) to achive 13.474 keV.
Crystal TypeSi(220) or Si(311)
MirrorsBent cylinders
Flux(PHOTONS/SEC)2.85 x 10^12
Flux Detailsfocused at 12.68 keV
Wavelength Range (Å)Fixed: 0.98
Energy Range (keV)Fixed: 12.68
GoniometerMaatel MD2
Goniometer DetailsMD2 Microdiffractometer (MK3 minikappa NOT available)
Sample Handling: RoboticsALS type automounter
Robotics: More InfoAutomounter has a capacity of 14 pucks (ALS or unipuck)
1. Detector: TypeCCD
1. Detector: ModelADSC QUANTUM 315
1. Detector: DetailsLR-Design detector positioner
1. Detector: Activated for Serviceinfo currently not available
1. Detector: Removed from Service2017-02-26
1. Removed from Service: DetailsReplaced with Dectris Eiger 16M
2. Detector: TypePIXEL
2. Detector: ModelDECTRIS EIGER 16M
2. Detector: DetailsDECTRIS EIGER 16M
2. Detector: Activated for Service2017-02-27
2. Detector: Removed from Service2017-02-26
Cryo CapabilityCryoJet from Oxford Instruments
Lab FacilitiesEssential wet lab facility exists. Cold room is available.
Software: NameBeam line is controlled by in house developed "Console" suite of programs. Automated data processing is enabled by locally developed software suite called RAPD. Most of the current crystallographic programs are made available via SBGrid distribution.
Software: Classification
HardwareData storage composed of three NeXan SataBeasts. SAN is accessed via high performance GPFS file system which gives upto 5 times the performance over NFS.
Backup ServicesExternal firewire and USB disks.