| Primary Contact: Name | Juan Sanchez-Weatherby |
| Owner/Operator | Diamond, Harwell Chilton Science Campus, South Oxfordshire, UK |
| Status | Operational |
| Experiments | MONOCHROMATIC |
| Special Capabilities | Absorption Edges, Adjustable Focus Mirrors |
| Services | Data collection, High quality data collection |
| Source Type | INSERTION DEVICE |
| Spot Size (mm): Height | 0.005 |
| Spot Size (mm): Width | 0.005 |
| Monochromator | Double Crystal Monochromator and Multilayer Monochromator |
| Crystal Type | Si (111), RuC |
| Flux(PHOTONS/SEC) | 4 x 10^14 |
| Flux Details | |
| Wavelength Range (Å) | 0.42 - 1.25 |
| Energy Range (keV) | 5 - 25 |
| Goniometer | Home-built |
| Sample Handling: Manual | fully automated low profile crystallisation plates |
| Detector: Type | PIXEL |
| Detector: Model | |
| Detector: Details | Eiger2 X 4M |
| Detector: Activated for Service | info currently not available |
| Detector: Removed from Service | |
| Cryo Capability | NONE |
| Lab Facilities | plate storage at 4C and 20C |
| Hardware | Fully automated beamline users select points for data collection and the beamline aligns and collects samples. Data is processed automatically. |