| Primary Contact: Name | Ritimukta Sarangi |
| Secondary Contact: Name | Matthew Latimer |
| Owner/Operator | SSRL-SMB-XAS |
| Status | Undergoing upgrade |
| Status Details | Mirror replacement |
| %Time Available (general use) | 100 |
| Experiments | EXAFS |
| Experiments Details | Beam line 9-3 is a wiggler side-station beam line dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. BL9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and Lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on BL9-3 is ideal for very dilute samples and single crystals. |
| Special Capabilities | Absorption Edges |
| Special Capabilities Details | Combined crystallography and XAS on the same crystal system. |
| Source Type | INSERTION DEVICE |
| Source Details | 16-pole, 2-Tesla wiggler - 2.5 mrad focused; 0.7 mrad unfocused |
| Spot Size (mm): Height | 0.3 focused; 2 unfocused |
| Spot Size (mm): Width | 4 focused; 20 unfocused |
| Monochromator | Liquid nitrogen-cooled double crystal, non-fixed exit slit |
| Crystal Type | Si(220), 2 phi orientations. |
| Mirrors | M0: Si, vertically collimating, Flat, Bent,1 m, Rh-coated; M1: Si, Bent, cylindrical, Rh coated, Zerodur |
| Flux(PHOTONS/SEC) | 2 x 10^12 |
| Flux Details | 9 keV, 100 mA, 3 GeV |
| Wavelength Range (Å) | info not available |
| Energy Range (keV) | 4.6 - 23 focused; 4.6 - 30 unfocused |
| Goniometer | Huber Kappa-geometry goniometer |
| Sample Handling: Manual | typical : 18 mm Cu magnetic mounts, flexible mount environment |
| Sample Handling: Robotics | manual |
| Detector: Type | 100-element Ge monolithic detector, ion chambers, Lytle and PIPS Si drift detector. |
| Detector: Model | Canberra |
| Detector: Activated for Service | info currently not available |
| Detector: Removed from Service | |
| Cryo Capability | Oxford CF1208 continuous flow liquid helium cryostat; Cryo Industries Cryocool-LHe |
| Cryo Capability Details | 10-200 K in cryostat, 20-200 K with cryostream |
| Lab Facilities | Sample preparation laboratory, cold room, glove boxes, microscopes |
| Software: Name | ICS (instrumentation control); XAS Collect (acquisition, Ge30Plus (detector setup), SRS570 (amplifier control), EXAFSPAK (analysis) |
| Software: Classification | Control, data acquisition, analysis |