| Primary Contact: Name | Ulrich Englich |
| Secondary Contact: Name | Marian Szebenyi |
| Owner/Operator | CHESS/MacCHESS |
| Status | Decommissioned |
| %Time Available (general use) | 10 |
| Experiments | SAD, MONOCHROMATIC |
| Experiments Details | high resolution multilayer monochromator |
| Special Capabilities | Long Wavelength, Microfocus |
| Services | Data collection |
| Services Details | mail-in upon request |
| Source Type | BENDING MAGNET |
| Source Details | hard bend magnet HB7E, 6mrad horizontal |
| Spot Size (mm): Height | 0.86 |
| Spot Size (mm): Width | 3.63 |
| Monochromator | Si(111) or 0.22% Al2O3/B4C multilayer |
| Optics Details | variable: Si (111), 0.22% high resolution multilayer, other multilayers |
| Flux(PHOTONS/SEC) | 4 x 10^9 through 0.3 mm collimator |
| Flux Details | |
| Wavelength Range (Å) | 0.8 - 2.1 |
| Energy Range (keV) | 5.9 - 15.4 |
| Goniometer | Single-axis ABTech air bearing with phi horizontal rotation axis. |
| Detector: Type | CCD |
| Detector: Model | ADSC Quantum 4r |
| Detector: Activated for Service | 2002-08-15 |
| Detector: Removed from Service | |
| Cryo Capability | Oxford Cryostream - 700 series |
| Cryo Capability Details | Programmable 80 to 400 K. Usually set to 100 K. |
| Lab Facilities | Cold room, small wet chemistry lab on-site. Biochemical lab with all equipment necessary for structural studies in Biotechnology Building (a 10-minute walk away). |
| Hardware | Linux computers for data collection, data processing, automatic crystal centering, backup and for station hardware control. |
| Backup Services | Wired and wireless network connections for user laptops. Ports for USB and FireWire external drives. SFTP to outside computers available. |