| Primary Contact: Name | James Holton |
| Secondary Contact: Name | Mehagan Hopkins |
| Owner/Operator | University of California San Francisco/Relay Therapeutics |
| Status | operational |
| %Time Available (general use) | 25 |
| Experiments | MAD |
| Experiments Details | "true MAD" : inverse beam and round-robin wavelength changes every image |
| Special Capabilities | in-situ tray screening: all SBS formats supported |
| Special Capabilities Details | arrange in advance |
| Services | unattended data collection |
| Services Details | all pin types supported |
| Source Type | BENDING MAGNET |
| Source Details | Superbend (5.0 tesla, single dipole) |
| Spot Size (mm): Height | 0.080 |
| Spot Size (mm): Width | 0.060 |
| Monochromator | KHOZU Double flat crystal |
| Optics Details | water cooled |
| Crystal Type | Si(111) |
| Mirrors | Pt and Rh-coated Si; M1: plane parabola M2: torroid (2:1 demagnification) |
| Flux(PHOTONS/SEC) | 1.0 x 10^12 |
| Flux Details | Measured @ 3x0.35 milliradian divergence at 11111 eV with ALS at 500 mA and 1.9 GeV. |
| Wavelength Range (Å) | 0.73 - 2.5 |
| Energy Range (keV) | 5. - 18 |
| Goniometer | Huber XYZ Stage ; 1.1 micron rms sphere of confusion |
| Goniometer Details | Air bearing for fast inverse beam measurements; motorized collimators: 100, 75 50, 30 20 microns diameter |
| Sample Handling: Manual | All pin types supported: lengths 9 mm to 30 mm |
| Sample Handling: Robotics | Cool Hand Luke |
| Robotics: More Info | Robot accepts all major pin types (Hampton, Yale, SPINE, etc.) and lengths (10-24 mm) and supports "delayed data collection mode" where data collection runs are deferred to the end of the shift. This robot does not work directly with cassettes because hand-mounting of samples in the mini-hutch is faster than any robot. |
| 1. Detector: Type | PIXEL |
| 1. Detector: Model | DECTRIS PILATUS 6M |
| 1. Detector: Details | Pilatus3 S, 100Hz, S/N 60-0134 |
| 1. Detector: Activated for Service | 2016-05-17 |
| 1. Detector: Removed from Service | |
| 2. Detector: Type | CCD |
| 2. Detector: Model | BRUKER PROTELUM 300 |
| 2. Detector: Details | SN: 1 |
| 2. Detector: Activated for Service | 2001-07-05 |
| 2. Detector: Removed from Service | 2001-08-05 |
| 2. Removed from Service: Details | detector moved to ALS 12.3.1 |
| 3. Detector: Type | CCD |
| 3. Detector: Model | ADSC Quantum 210 |
| 3. Detector: Details | SN: 442 |
| 3. Detector: Activated for Service | 2001-08-09 |
| 3. Detector: Removed from Service | 2002-10-24 |
| 3. Removed from Service: Details | detector moved to ALS 12.3.1 |
| 4. Detector: Type | CCD |
| 4. Detector: Model | ADSC Quantum 315 |
| 4. Detector: Details | SN: 907 |
| 4. Detector: Activated for Service | 2002-12-06 |
| 4. Detector: Removed from Service | 2003-08-10 |
| 4. Removed from Service: Details | detector moved to ALS 12.3.1 |
| 5. Detector: Type | CCD |
| 5. Detector: Model | ADSC Quantum 210 |
| 5. Detector: Details | SN: 442 |
| 5. Detector: Activated for Service | 2003-08-12 |
| 5. Detector: Removed from Service | 2007-05-13 |
| 6. Detector: Type | CCD |
| 6. Detector: Model | ADSC Quantum 315r |
| 6. Detector: Details | SN: 926 |
| 6. Detector: Activated for Service | 2007-06-20 |
| 6. Detector: Removed from Service | 2016-05-17 |
| Cryo Capability | Oxford Cryojet ~100K, coaxial |
| Cryo Capability Details | user-controllable temperature up to 45C |
| Lab Facilities | Biochemical lab with all equipment necessary for structural studies. Cold room available. Reserve in advance. |
| Software: Name | CCP4, Mosflm, ELVES, XDS, DIALS |
| Software: Classification | |
| Hardware | single server: 224 CPU, 3 TB RAM, 180 TB disk, 70s to process 3600 images |
| Backup Services | Firewire/USB3 drives, automated DVD or Blu-Ray |
| Serial Crystallography Collimation/Focusing Optics | parabola/torroid |
| Beam Focal Spot Size at Sample (µm^2) | 60 x 80 (h x v) |
| Serial Crystallography Details | user-provided LCP jet collection supported |
| Fixed Sample Target Details | all SBS trays supported |
| Fixed Sample Motion Control Device | in-house "tray goniometer" |
| Sample Dehydration Prevention Method | MiTeGen Watershed |