| Owner/Operator | Albert Einstein College of Medicine, Sloan-Kettering Institute, Rockefeller University, Case Western Reserve University |
| Status | This beamline was shut down September 30, 2014 |
| Status Details | This beamline was shut down on September 30, 2014 |
| %Time Available (general use) | 25 |
| Experiments | MAD |
| Spot Size (mm): Height | 0.6H |
| Spot Size (mm): Width | 0.1V mm |
| Flux(PHOTONS/SEC) | 2.4 x 10^E(10) X-Ray photons per second through a 0.2mm aperture, 207mA current, wavelength of 0.98 Ang. |
| Flux Details | Flux measured in 2004 |
| Wavelength Range (Å) | 0.84 - 1.85 |
| Energy Range (keV) | 4.6 - 15.1 |
| Goniometer | MAR rotation camera |
| Detector: Type | CCD |
| Detector: Model | MAR 165mm |
| Detector: Activated for Service | info currently not available |
| Detector: Removed from Service | |
| Cryo Capability | Oxford Cryo-Jet. |
| Lab Facilities | basic users lab, Microscope and coldroom available |
| Software: Name | MarCCD software, ADX,HKL2000 and many crystallographic softwares (HKL2MAP, SHELX suit; SOLVE/RESOLVE; CCP4; COOT; PyMol, Xfit). |
| Software: Classification | |
| Hardware | SGI Octane R12000, Dual P750 and WinPC |
| Backup Services | Robotic DVD burner; External Hard Drive; 4mm DAT tape |