| Primary Contact: Name | Leonid Flaks |
| Secondary Contact: Name | Mirek Cygler |
| Owner/Operator | National Research Council Canada, BNL-Bio, Hoffmann-La Roche, BiogenIdec |
| Status | This beamline was shut down September 30, 2014 |
| Status Details | This beamline was shut down on September 30, 2014 |
| %Time Available (general use) | 25 |
| Experiments | MAD |
| Source Type | bending magnet |
| Spot Size (mm): Width | Automated slits allow the beam size to be match to the crystal size or reduced to minimize spatial overlap of diffraction spots. |
| Crystal Type | Si (111) |
| Flux(PHOTONS/SEC) | 1.1 x 10^10 |
| Flux Details | Flux measured in 1997 corresponds to NSLS x-ray ring emittance of 90 nm-rad; NSLS x-ray ring emittance has improved to 45 nm-rad, and this has resulted in about a factor of 2 increase in the deliv |
| Wavelength Range (Å) | 0.6 |
| Energy Range (keV) | 2 - 20 |
| Goniometer | ADSC CrystalLogic |
| Detector: Type | CCD |
| Detector: Model | ADSC QUANTUM 4r |
| Detector: Activated for Service | info currently not available |
| Detector: Removed from Service | |
| Cryo Capability | Oxford Cryostream with automatic fill from a 120-liter dewar |
| Lab Facilities | there is a wet lab space associated with the beam line (room 1-164). It is well-equipped for crystallization and crystal mounting and includes half of a cold room. |
| Software: Name | Full set of crystalographic software |
| Software: Classification | |
| Hardware | Linux Fedora |
| Backup Services | USB, FireWire, DVD, tape drives |