| Primary Contact: Name | Vincent Olieric |
| Secondary Contact: Name | Justyna Wojdyla |
| Owner/Operator | Paul Scherrer Institut |
| Status | Operational |
| %Time Available (general use) | 70 |
| Experiments | MAD |
| Special Capabilities | Multi-axis goniometry (PRIGo) |
| Special Capabilities Details | Automated in-situ diffraction screening with various SBS crystallization plates format |
| Services | On-site crystallization |
| Source Type | bending magnet |
| Source Details | 2.9T superbend magnet. |
| Spot Size (mm): Height | 0.09 |
| Spot Size (mm): Width | 0.07 |
| Monochromator | Bartels Monochromator |
| Crystal Type | Si (111) |
| Mirrors | toroidal focusing |
| Flux(PHOTONS/SEC) | 4 x 10^11 |
| Flux Details | at 400 mA |
| Wavelength Range (Å) | 0.71 - 2.07 |
| Energy Range (keV) | 6 - 17.5 |
| Goniometer | Multi-axis goniometer |
| Goniometer Details | PRIGo |
| Sample Handling: Manual | pin length = 10 - 30 mm |
| Sample Handling: Robotics | TELL |
| Robotics: More Info | 18mm SPINE sample holders. Unipucks. |
| 1. Detector: Type | CCD |
| 1. Detector: Model | MARMOSAIC 225 |
| 1. Detector: Activated for Service | 2007-11-06 |
| 1. Detector: Removed from Service | 2011-10-31 |
| 1. Removed from Service: Details | replaced by a PILATUS 2M-F |
| 2. Detector: Type | PIXEL |
| 2. Detector: Model | DECTRIS PILATUS 2M-F |
| 2. Detector: Activated for Service | 2011-11-16 |
| 2. Detector: Removed from Service | |
| Cryo Capability | Oxford cryojet |
| Cryo Capability Details | fast cooling (5 min) |