Primary Contact: Name | Naohiro Matsugaki |
Owner/Operator | Structural Biology Research Center |
Status | operational |
%Time Available (general use) | 80 |
Experiments | MONOCHROMATIC |
Experiments Details | SAD/MAD at wide energy range |
Special Capabilities | High Resolution |
Special Capabilities Details | upto 0.75A resolution with short wavelength beam |
Source Type | INSERTION DEVICE |
Source Details | Multipole Wiggler |
Spot Size (mm): Height | 0.17 |
Spot Size (mm): Width | 0.2 |
Monochromator | Cryo-cooled numerical link type Si(111) double crystal monochromator |
Crystal Type | Si(111) |
Mirrors | Collimating mirror: Rhodium coated silicon single crystal (Flat), Focusing mirror:Rhodium coated silicon single crystal (Troidal) |
Flux(PHOTONS/SEC) | 2 x 10^11 |
Flux Details | at 1.0 A |
Wavelength Range (Å) | 0.75 - 1.9 |
Energy Range (keV) | 6.5 - 16.5 |
Goniometer | single axis |
Sample Handling: Manual | Hampton copper magnetic or its compatibles of 18mm length |
Sample Handling: Robotics | PF automated mounting system PAM |
Detector: Type | PIXEL |
Detector: Model | DECTRIS PILATUS 6M |
Detector: Details | PILATUS S6M |
Detector: Activated for Service | 2018-05-10 |
Detector: Removed from Service | 2017-12-31 |
Removed from Service: Details | ADSC Quantum 315r was removed |
Cryo Capability | Rigaku Cryo-cooler |
Cryo Capability Details | nitrogen gas flow at 95K |
Lab Facilities | NORMAL |
Software: Name | XDS, HKL2000, iMosflm |
Software: Classification | |
Backup Services | portable HDD (USB) |