2024-04-30 04:31:44 |
Experiments Details |
Anomalous difraction experiments, on-line UV-Vis absorption spectroscopy |
Anomalous difraction experiments, on-line UV-Vis absorption spectroscopy |
2024-04-30 04:30:14 |
Cryo Capability |
Oxford |
Oxford |
2024-04-30 04:30:08 |
Cryo Capability Details |
100 to 298 K |
80 to 400 K |
2024-04-30 04:29:20 |
Sample Handling: Robotics |
FLEX-HCD unipucks |
Flex-HCD |
2024-04-30 04:28:53 |
Sample Handling: Manual |
|
B5 (Spine type) base 21 mm pin lenght |
2024-04-30 04:28:16 |
Goniometer |
|
MiniDiff + Kappa |
2024-04-30 04:27:51 |
Mirrors |
|
cylindrical Rh coated |
2024-04-30 04:27:31 |
Crystal Type |
|
Si (111) |
2024-04-30 04:27:21 |
Monochromator |
|
double crystal DCM |
2024-04-30 04:27:03 |
Source Details |
2 poles wiggler option A |
2-Pole Wiggler in configuration A (2PWA) |
2024-04-30 04:26:43 |
Source Details |
2 poles wiggler option A |
2 poles wiggler option A |
2024-04-30 04:26:35 |
Source Details |
2poleswiggler option A |
2 poles wiggler option A |
2024-04-30 04:26:27 |
Source Details |
|
2poleswiggler option A |
2024-04-30 04:24:31 |
Source Type |
BENDING MAGNET |
BENDING MAGNET |
2024-04-30 04:23:38 |
Robotics: More Info |
|
unipucks |
2024-04-30 04:23:26 |
Sample Handling: Robotics |
|
FLEX-HCD unipucks |
2024-04-30 04:22:46 |
Energy Range (keV): Max |
17 |
21 |
2024-04-30 04:22:42 |
Energy Range (keV): Min |
7 |
6 |
2024-04-30 04:22:31 |
Flux Details |
1x10^12 ph/s at 12 KeV with 200x200 um beam |
7x10^11 ph/s at 12 KeV with 250x250 um beam |
2022-12-22 01:42:40 |
Flux Details |
1x10e12 ph/s at 12 KeV with 200x200 um beam |
1x10^12 ph/s at 12 KeV with 200x200 um beam |
2022-12-22 01:42:20 |
Flux Details |
|
1x10e12 ph/s at 12 KeV with 200x200 um beam |
2022-12-22 01:41:40 |
Spot Size (mm): Width |
0.1 to 0.3 |
0.075 to 0.3 |
2022-12-22 01:41:34 |
Spot Size (mm): Height |
0.1 to 0.3 |
0.075 to 0.3 |
2022-12-22 01:41:28 |
Spot Size (mm): Width |
0.23 |
0.1 to 0.3 |
2022-12-22 01:41:17 |
Spot Size (mm): Height |
0.06 |
0.1 to 0.3 |
2022-12-22 01:39:16 |
Lab Facilities |
|
NORMAL |
2022-12-22 01:39:10 |
Cryo Capability Details |
|
100 to 298 K |
2022-12-22 01:39:01 |
Cryo Capability Details |
|
|
2022-12-22 01:38:59 |
Cryo Capability |
|
Oxford |
2022-12-22 01:38:40 |
Detector: Model |
|
DECTRIS PILATUS 6M |
2022-12-22 01:38:33 |
Detector: Type |
|
PIXEL |
2022-12-22 01:38:27 |
Detector: Activated for Service |
2022-06-01 |
2021-06-01 |
2022-12-22 01:38:19 |
Detector: Activated for Service |
info currently not available |
2022-06-01 |
2022-12-22 01:32:47 |
Source Type |
BENDING MAGNET |
BENDING MAGNET |
2022-12-22 01:32:29 |
Experiments Details |
Anomalous difraction experiments, on-line UV-VIs absorption spectroscopy |
Anomalous difraction experiments, on-line UV-Vis absorption spectroscopy |
2022-02-10 12:50:44 |
Primary Contact: Email |
|
antoine.royant@esrf.fr |
2022-02-10 12:50:34 |
Primary Contact: Name |
Antione Royant |
Antoine Royant |
2022-02-10 12:50:23 |
Primary Contact: Name |
|
Antione Royant |
2022-02-10 12:47:32 |
Experiments |
MAD, SAD, HIGH PRESSURE |
MAD, SAD, MONOCHROMATIC, FLUORESCENCE, HIGH PRESSURE |
2022-02-10 12:47:10 |
Experiments |
MONOCHROMATIC, FLUORESCENCE, HIGH PRESSURE |
MAD, SAD, HIGH PRESSURE |
2022-02-10 12:46:19 |
Experiments Details |
|
Anomalous difraction experiments, on-line UV-VIs absorption spectroscopy |
2022-02-10 12:45:16 |
Experiments |
|
MONOCHROMATIC, FLUORESCENCE, HIGH PRESSURE |
2022-02-10 12:44:08 |
Status Details |
|
Replaces FIP-BM30A |
2022-02-10 12:43:28 |
Owner/Operator |
French beamline for Investigation of Proteins (FIP2) |
French Beamline for Investigation of Proteins (FIP2) |
2022-02-10 12:43:15 |
Owner/Operator |
|
French beamline for Investigation of Proteins (FIP2) |