Change history for SPRING-8 - BL38B1

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2013-02-13 09:55:15 Spot Size (mm): Width 0.23-0.13 0.087
2013-02-13 09:54:58 Spot Size (mm): Height 0.20-0.08 0.053-0.180
2013-02-13 09:53:43 Energy Range (keV): Max 17.7 16.5
2013-02-13 09:53:38 Energy Range (keV): Min 6.9 6.5
2013-02-13 09:53:28 Wavelength (Å): Max 1.80 1.90
2013-02-13 09:53:24 Wavelength (Å): Min 0.70 0.75
2013-02-13 09:52:30 Hardware UV-Vis microspectrophotometer
2013-02-13 09:50:51 Flux Details Wavelength 1.0 A, beam size 0.20x0.23 mm Wavelength 1.0 A, beam size 0.087x0.180 mm
2013-02-13 09:50:27 Flux Coefficient 8.4 9.3
2012-08-17 04:29:07 Detector: Model ADSC Quantum 315 ADSC Quantum 315r
2012-08-17 04:28:49 Robotics: More Info Sample Magazine: 2 Uni-pucks or 2 SPACE trays
2012-08-17 04:26:02 Beamline Website http://www.spring8.or.jp/wkg/BL38B1/instrument/lang-en/INS-0000000577/instrument_summary_view http://bioxtal.spring8.or.jp/en/BL/BL38B1/BL38B1_en.html
2012-08-17 04:25:14 Secondary Contact: Email bioxtal@spring8.or.jp
2012-08-17 04:25:03 Secondary Contact: Name Takashi Kumasaka
2011-06-27 10:42:49 Beamline Website http://bioxtal.spring8.or.jp/index_en.html http://www.spring8.or.jp/wkg/BL38B1/instrument/lang-en/INS-0000000577/instrument_summary_view
2010-10-26 09:39:41 Detector: Model ADSC Quantum 210 ADSC Quantum 315
2010-10-26 09:39:20 Beamline Website http://www.spring8.or.jp/wkg/BL38B1/instrument/lang-en/INS-0000000577/instrument_summary_view http://bioxtal.spring8.or.jp/index_en.html
2009-10-06 04:43:01 Sample Handling: Robotics (SPACE) Spring-8 Precise Automatic Cryo-Sample Exchanger
2009-10-06 04:42:27 Energy Range (keV): Min 6.51 6.9
2009-10-06 04:42:14 Energy Range (keV): Max 17.5 17.7
2009-10-06 04:41:52 Wavelength (Å): Max 1.907 1.80
2009-10-06 04:41:33 Wavelength (Å): Min 0.708 0.70
2009-10-06 04:39:15 Services Data collection, Mail-in
2009-10-06 04:37:23 Crystal Type Si (111)
2009-10-06 04:36:13 Flux Details Wavelength 1.0 A, beam size 0.20x0.23 mm
2009-10-06 04:35:11 Flux Exponent 11 10
2009-10-06 04:35:06 Flux Coefficient 1 8.4
2009-10-06 04:34:03 Spot Size (mm): Width 2.5 0.23-0.13
2009-10-06 04:33:41 Spot Size (mm): Height 2 0.20-0.08
2009-10-06 04:32:34 Detector: Model RIGAKU JUPITER 210 ADSC Quantum 210
2009-10-06 04:32:21 Detector: Type IMAGE PLATE CCD
2009-10-06 04:31:02 Mirrors Vertically bent cylinder mirror coated in Rhodium Vertically bent cylinderical mirror coated in Rhodium
2009-10-06 04:30:49 Mirrors vertically bent cylinder mirror coated in Rhodium Vertically bent cylinder mirror coated in Rhodium
2009-10-06 04:30:21 Source Type BENDING MAGNET
2009-10-06 04:29:40 Experiments SAD, MONOCHROMATIC MAD, SAD, MONOCHROMATIC
2009-10-06 04:29:30 Experiments MAD, XAFS SAD, MONOCHROMATIC
2009-10-06 04:29:13 %Time Available (general use) 80
2009-10-06 04:29:08 Status operational Operational
2009-10-06 04:29:04 Owner/Operator Japan Synchrotron Radiation Research Institute (JASRI)
2009-10-06 04:28:45 Secondary Contact: Email kumasaka@spring8.or.jp
2009-10-06 04:28:39 Secondary Contact: Name Nobuhiro Mizuno
2009-10-06 04:28:09 Secondary Contact: Name Takashi Kumasaka Nobuhiro Mizuno
2009-08-17 02:46:38 Secondary Contact: Email kumasaka@spring8.or.jp
2009-08-17 02:46:24 Primary Contact: Email baba@spring8.or.jp
2009-07-25 07:28:46 Beamline Website http://www.spring8.or.jp/wkg/BL38B1/instrument/lang-en/INS-0000000385/instrument_summary_view http://www.spring8.or.jp/wkg/BL38B1/instrument/lang-en/INS-0000000577/instrument_summary_view