Change history for SPRING-8 - BL32XU

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2011-09-09 09:20:36 Source Type BENDING MAGNET INSERTION DEVICE
2011-09-08 08:45:36 Wavelength (Å): Max 1.459
2011-09-08 08:45:28 Wavelength (Å): Min 0.6199
2011-09-08 08:43:41 Flux Coefficient 6 or 4 6
2011-09-08 08:43:37 Flux Exponent 10 or 12 10
2011-09-08 08:41:52 Owner/Operator SR Life Science Instrumention Unit RIKEN/SPring-8 Center, Research Infrastructure Group, SR Life Science Instrumention Unit
2011-09-08 08:41:13 Mirrors K-B focusing mirrors K-B mirrors fabricated with EEM (Elastic Emission Machining) technique (Osaka mirror)
2011-09-08 08:40:06 Energy Range (keV): Max 20
2011-09-08 08:40:01 Energy Range (keV): Min 8.5
2011-09-08 08:39:28 Flux Exponent 10 10 or 12
2011-09-08 08:39:18 Flux Coefficient 6 6 or 4
2011-09-08 08:39:03 Flux Details 6E10 for 1x1 um2 , 4E12 for 10 x 10 um2
2011-09-08 08:37:20 Spot Size (mm): Width 0.01 - 0.010 (chooseable) 0.001 - 0.010 (chooseable)
2011-09-08 08:37:08 Spot Size (mm): Width 0.1 0.01 - 0.010 (chooseable)
2011-09-08 08:36:38 Spot Size (mm): Height 0.1 0.001 - 0.010 (chooseable)
2011-06-27 10:03:44 Beamline Website http://www.spring8.or.jp/wkg/BL32XU/instrument/lang-en/INS-0000001392/instrument_summary_view http://www.spring8.or.jp/wkg/BL32XU/instrument/lang-en/INS-0000001513/instrument_summary_view
2011-06-27 09:58:31 Goniometer air-baring goiniometer
2011-06-27 09:58:00 Detector: Model RAYONIX MX-225 HE
2011-06-27 09:57:59 Detector: Activated for Service info currently not available 2011-05-01
2011-06-27 09:57:08 Detector: Details
2011-06-27 09:56:43 Detector: Type CCD
2011-06-27 09:56:38 Sample Handling: Robotics (SPACE) Spring-8 Precise Automatic Cryo-Sample Exchanger
2011-06-27 09:56:21 Flux Exponent 10
2011-06-27 09:56:16 Flux Coefficient 6
2011-06-27 09:55:57 Mirrors K-B focusing mirrors
2011-06-27 09:55:50 Optics Details K-B focusing mirrors
2011-06-27 09:55:39 Optics Details K-B focusing mirrors
2011-06-27 09:54:18 Crystal Type Si (111)
2011-06-27 09:54:10 Monochromator liquid nitrogen cooled double crystal
2011-06-27 09:53:49 Spot Size (mm): Width 0.1
2011-06-27 09:53:45 Spot Size (mm): Height 0.1
2011-06-27 09:53:34 Source Type BENDING MAGNET
2011-06-27 09:53:20 Experiments Details Targeted Proteins Research Program promoted by MEXT of Japan
2011-06-27 09:52:27 Special Capabilities Microfocus
2011-06-27 09:51:57 Experiments MAD, SAD MAD, SAD
2011-06-27 09:51:37 Experiments MAD, SAD
2011-06-27 09:50:07 Status Details undergoing checkout after the March 2011 earthquake
2011-06-27 09:49:20 Primary Contact: Email hirata@spring8.or.jp
2011-06-27 09:48:58 Primary Contact: Name Kunio Hirata
2011-06-27 09:48:43 Status Under construction Operational
2011-06-27 09:48:38 Beamline Website http://www.spring8.or.jp/wkg/BL35XU/instrument/lang-en/INS-0000001392/instrument_summary_view http://www.spring8.or.jp/wkg/BL32XU/instrument/lang-en/INS-0000001392/instrument_summary_view
2011-06-27 09:47:54 Status Details undergoing checkout after the March 2011 earthquake
2011-06-27 09:47:18 Owner/Operator RIKEN Harima Institute SR Life Science Instrumention Unit
2011-06-27 09:46:38 Beamline Website http://www.spring8.or.jp/wkg/BL35XU/instrument/lang-en/INS-0000001392/instrument_summary_view