2011-09-09 09:20:36 |
Source Type |
BENDING MAGNET |
INSERTION DEVICE |
2011-09-08 08:45:36 |
Wavelength (Å): Max |
|
1.459 |
2011-09-08 08:45:28 |
Wavelength (Å): Min |
|
0.6199 |
2011-09-08 08:43:41 |
Flux Coefficient |
6 or 4 |
6 |
2011-09-08 08:43:37 |
Flux Exponent |
10 or 12 |
10 |
2011-09-08 08:41:52 |
Owner/Operator |
SR Life Science Instrumention Unit |
RIKEN/SPring-8 Center, Research Infrastructure Group, SR Life Science Instrumention Unit |
2011-09-08 08:41:13 |
Mirrors |
K-B focusing mirrors |
K-B mirrors fabricated with EEM (Elastic Emission Machining) technique (Osaka mirror) |
2011-09-08 08:40:06 |
Energy Range (keV): Max |
|
20 |
2011-09-08 08:40:01 |
Energy Range (keV): Min |
|
8.5 |
2011-09-08 08:39:28 |
Flux Exponent |
10 |
10 or 12 |
2011-09-08 08:39:18 |
Flux Coefficient |
6 |
6 or 4 |
2011-09-08 08:39:03 |
Flux Details |
|
6E10 for 1x1 um2 , 4E12 for 10 x 10 um2 |
2011-09-08 08:37:20 |
Spot Size (mm): Width |
0.01 - 0.010 (chooseable) |
0.001 - 0.010 (chooseable) |
2011-09-08 08:37:08 |
Spot Size (mm): Width |
0.1 |
0.01 - 0.010 (chooseable) |
2011-09-08 08:36:38 |
Spot Size (mm): Height |
0.1 |
0.001 - 0.010 (chooseable) |
2011-06-27 10:03:44 |
Beamline Website |
http://www.spring8.or.jp/wkg/BL32XU/instrument/lang-en/INS-0000001392/instrument_summary_view |
http://www.spring8.or.jp/wkg/BL32XU/instrument/lang-en/INS-0000001513/instrument_summary_view |
2011-06-27 09:58:31 |
Goniometer |
|
air-baring goiniometer |
2011-06-27 09:58:00 |
Detector: Model |
|
RAYONIX MX-225 HE |
2011-06-27 09:57:59 |
Detector: Activated for Service |
info currently not available |
2011-05-01 |
2011-06-27 09:57:08 |
Detector: Details |
|
|
2011-06-27 09:56:43 |
Detector: Type |
|
CCD |
2011-06-27 09:56:38 |
Sample Handling: Robotics |
|
(SPACE) Spring-8 Precise Automatic Cryo-Sample Exchanger |
2011-06-27 09:56:21 |
Flux Exponent |
|
10 |
2011-06-27 09:56:16 |
Flux Coefficient |
|
6 |
2011-06-27 09:55:57 |
Mirrors |
|
K-B focusing mirrors |
2011-06-27 09:55:50 |
Optics Details |
K-B focusing mirrors |
|
2011-06-27 09:55:39 |
Optics Details |
|
K-B focusing mirrors |
2011-06-27 09:54:18 |
Crystal Type |
|
Si (111) |
2011-06-27 09:54:10 |
Monochromator |
|
liquid nitrogen cooled double crystal |
2011-06-27 09:53:49 |
Spot Size (mm): Width |
|
0.1 |
2011-06-27 09:53:45 |
Spot Size (mm): Height |
|
0.1 |
2011-06-27 09:53:34 |
Source Type |
|
BENDING MAGNET |
2011-06-27 09:53:20 |
Experiments Details |
|
Targeted Proteins Research Program promoted by MEXT of Japan |
2011-06-27 09:52:27 |
Special Capabilities |
|
Microfocus |
2011-06-27 09:51:57 |
Experiments |
MAD, SAD |
MAD, SAD |
2011-06-27 09:51:37 |
Experiments |
|
MAD, SAD |
2011-06-27 09:50:07 |
Status Details |
undergoing checkout after the March 2011 earthquake |
|
2011-06-27 09:49:20 |
Primary Contact: Email |
|
hirata@spring8.or.jp |
2011-06-27 09:48:58 |
Primary Contact: Name |
|
Kunio Hirata |
2011-06-27 09:48:43 |
Status |
Under construction |
Operational |
2011-06-27 09:48:38 |
Beamline Website |
http://www.spring8.or.jp/wkg/BL35XU/instrument/lang-en/INS-0000001392/instrument_summary_view |
http://www.spring8.or.jp/wkg/BL32XU/instrument/lang-en/INS-0000001392/instrument_summary_view |
2011-06-27 09:47:54 |
Status Details |
|
undergoing checkout after the March 2011 earthquake |
2011-06-27 09:47:18 |
Owner/Operator |
RIKEN Harima Institute |
SR Life Science Instrumention Unit |
2011-06-27 09:46:38 |
Beamline Website |
|
http://www.spring8.or.jp/wkg/BL35XU/instrument/lang-en/INS-0000001392/instrument_summary_view |