Change history for SSRL - BL9-3

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2014-10-01 11:08:30 Status Details Mirror Upgrade Mirror replacement
2014-10-01 11:08:15 Status Details Open Mirror Upgrade
2014-10-01 12:10:18 Status Operational Undergoing upgrade
2014-09-30 06:22:53 Cryo Capability Oxford CF1208 continuous flow liquid helium cryostat; Cryoindustries Cryocool-LHe Oxford CF1208 continuous flow liquid helium cryostat; Cryo Industries Cryocool-LHe
2014-09-30 06:21:45 Cryo Capability Oxford Liquid He cryostat and Oxford open flow liq He cryostream Oxford CF1208 continuous flow liquid helium cryostat; Cryoindustries Cryocool-LHe
2014-09-30 06:21:09 Cryo Capability Details 5-200 K in cryostat, 20-200 K with cryostream 10-200 K in cryostat, 20-200 K with cryostream
2014-09-30 12:43:29 Software: Classification Control, data acquisition, analysis
2014-09-30 12:43:05 Backup Services Local: CD writer (PC); Network: FTP, autobackup to server; Backup server: 4 mm DAT, 8 mm, TK50, CD writer (OpenVMS)
2014-09-30 12:43:01 Hardware DECAlpha 250 4/266 (OpenVMS); PC (Windows NT); Terminal server (Windows 2000); OpenVMS server access
2014-09-30 12:20:17 Lab Facilities Sample preparation laboratory, Cold room, glove boxes, microscopes Sample preparation laboratory, cold room, glove boxes, microscopes
2014-09-30 12:19:34 Detector: Type 100 element Ge monolith detector, ion chambers, lytle and PIPS silicon drift detector. 100-element Ge monolithic detector, ion chambers, Lytle and PIPS Si drift detector.
2014-09-30 12:18:59 Goniometer Huber Kappa geometry goniometer Huber Kappa-geometry goniometer
2014-09-30 12:18:51 Goniometer Huber Kappa Huber Kappa geometry goniometer
2014-09-30 12:18:39 Flux Details at 9 keV, 100 mA, 3 GeV 9 keV, 100 mA, 3 GeV
2014-09-30 12:18:08 Crystal Type Si(220), 2 phi orientations; LN2 cooled Si(220), 2 phi orientations.
2014-09-30 12:17:26 Monochromator In-vacuum; non-fixed exit slit; double flat crystal; double sets Liquid nitrogen-cooled double crystal, non-fixed exit slit
2014-09-30 12:15:40 Spot Size (mm): Height 0.3 focused; 1 unfocused 0.3 focused; 2 unfocused
2014-09-30 12:15:28 Spot Size (mm): Width 4 focused; 2 x 20 unfocused (vertical x horizontal) 4 focused; 20 unfocused
2014-09-30 12:15:02 Spot Size (mm): Height 0.3 focused; 2 unfocused 0.3 focused; 1 unfocused
2014-09-30 12:14:57 Spot Size (mm): Height 1 0.3 focused; 2 unfocused
2014-09-30 12:14:42 Special Capabilities Details combined XRD and XAS on the same crystal system. Combined crystallography and XAS on the same crystal system.
2014-09-30 12:14:25 Experiments Details Beamline 9-3 is a wiggler side-station beamline dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. 9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on 9-3 is ideal for very dilute samples and single crystals. Beam line 9-3 is a wiggler side-station beam line dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. BL9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and Lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on BL9-3 is ideal for very dilute samples and single crystals.
2014-09-30 12:14:21 Status Details open Open
2014-09-30 12:14:16 Status operational Operational
2014-02-21 06:22:41 Mirrors M0: Flat, bent, Rh-coated, Si; M1: Bent, cylindrical, Rh coated, Zerodur M0: Si, vertically collimating, Flat, Bent,1 m, Rh-coated; M1: Si, Bent, cylindrical, Rh coated, Zerodur
2014-02-21 06:17:03 Lab Facilities Sample prep lab; coldroom Sample preparation laboratory, Cold room, glove boxes, microscopes
2014-02-21 06:16:23 Cryo Capability Details 5-200 K in cryostat, 20-200 K with cryostream
2014-02-21 06:15:47 Cryo Capability LHe, continuous flow Oxford Liquid He cryostat and Oxford open flow liq He cryostream
2014-02-21 06:14:48 Status Details open
2014-02-21 06:14:40 Experiments EXAFS EXAFS
2014-02-21 06:14:28 Detector: Model Canberra
2014-02-21 06:14:11 Detector: Type 30-element Ge solid state array; Lytle detector; ion chambers 100 element Ge monolith detector, ion chambers, lytle and PIPS silicon drift detector.
2014-02-21 06:13:30 Sample Handling: Robotics manual
2014-02-21 06:13:14 Sample Handling: Manual typical : 18 mm Cu magnetic mounts, flexible mount environment
2014-02-21 06:12:34 Goniometer Huber Kappa
2014-02-21 06:11:52 Spot Size (mm): Height 0.7 1
2014-02-21 06:11:41 Special Capabilities Details combined XRD and XAS on the same system. combined XRD and XAS on the same crystal system.
2014-02-21 06:11:32 Special Capabilities Details combined XRD and XAS on the same system.
2014-02-21 06:10:50 Source Type INSERTION DEVICE
2014-02-21 06:10:29 Special Capabilities n/a Absorption Edges
2014-02-21 06:10:07 Experiments Details Beamline 9-3 is a wiggler side-station beamline dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. 9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on 9-3 is ideal for very dilute samples and single crystals.
2014-02-21 06:09:26 Experiments XAS EXAFS
2014-02-21 06:09:03 Secondary Contact: Email latimer@SLAC.Stanford.EDU latimer@slac.stanford.edu
2014-02-21 06:08:52 Primary Contact: Name Serena DeBeer George Ritimukta Sarangi
2014-02-21 06:08:45 Primary Contact: Email serena@slac.stanford.edu ritis@slac.stanford.edu