2014-10-01 11:08:30 |
Status Details |
Mirror Upgrade |
Mirror replacement |
2014-10-01 11:08:15 |
Status Details |
Open |
Mirror Upgrade |
2014-10-01 12:10:18 |
Status |
Operational |
Undergoing upgrade |
2014-09-30 06:22:53 |
Cryo Capability |
Oxford CF1208 continuous flow liquid helium cryostat; Cryoindustries Cryocool-LHe |
Oxford CF1208 continuous flow liquid helium cryostat; Cryo Industries Cryocool-LHe |
2014-09-30 06:21:45 |
Cryo Capability |
Oxford Liquid He cryostat and Oxford open flow liq He cryostream |
Oxford CF1208 continuous flow liquid helium cryostat; Cryoindustries Cryocool-LHe |
2014-09-30 06:21:09 |
Cryo Capability Details |
5-200 K in cryostat, 20-200 K with cryostream |
10-200 K in cryostat, 20-200 K with cryostream |
2014-09-30 12:43:29 |
Software: Classification |
|
Control, data acquisition, analysis |
2014-09-30 12:43:05 |
Backup Services |
Local: CD writer (PC); Network: FTP, autobackup to server; Backup server: 4 mm DAT, 8 mm, TK50, CD writer (OpenVMS) |
|
2014-09-30 12:43:01 |
Hardware |
DECAlpha 250 4/266 (OpenVMS); PC (Windows NT); Terminal server (Windows 2000); OpenVMS server access |
|
2014-09-30 12:20:17 |
Lab Facilities |
Sample preparation laboratory, Cold room, glove boxes, microscopes |
Sample preparation laboratory, cold room, glove boxes, microscopes |
2014-09-30 12:19:34 |
Detector: Type |
100 element Ge monolith detector, ion chambers, lytle and PIPS silicon drift detector. |
100-element Ge monolithic detector, ion chambers, Lytle and PIPS Si drift detector. |
2014-09-30 12:18:59 |
Goniometer |
Huber Kappa geometry goniometer |
Huber Kappa-geometry goniometer |
2014-09-30 12:18:51 |
Goniometer |
Huber Kappa |
Huber Kappa geometry goniometer |
2014-09-30 12:18:39 |
Flux Details |
at 9 keV, 100 mA, 3 GeV |
9 keV, 100 mA, 3 GeV |
2014-09-30 12:18:08 |
Crystal Type |
Si(220), 2 phi orientations; LN2 cooled |
Si(220), 2 phi orientations. |
2014-09-30 12:17:26 |
Monochromator |
In-vacuum; non-fixed exit slit; double flat crystal; double sets |
Liquid nitrogen-cooled double crystal, non-fixed exit slit |
2014-09-30 12:15:40 |
Spot Size (mm): Height |
0.3 focused; 1 unfocused |
0.3 focused; 2 unfocused |
2014-09-30 12:15:28 |
Spot Size (mm): Width |
4 focused; 2 x 20 unfocused (vertical x horizontal) |
4 focused; 20 unfocused |
2014-09-30 12:15:02 |
Spot Size (mm): Height |
0.3 focused; 2 unfocused |
0.3 focused; 1 unfocused |
2014-09-30 12:14:57 |
Spot Size (mm): Height |
1 |
0.3 focused; 2 unfocused |
2014-09-30 12:14:42 |
Special Capabilities Details |
combined XRD and XAS on the same crystal system. |
Combined crystallography and XAS on the same crystal system. |
2014-09-30 12:14:25 |
Experiments Details |
Beamline 9-3 is a wiggler side-station beamline dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. 9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on 9-3 is ideal for very dilute samples and single crystals. |
Beam line 9-3 is a wiggler side-station beam line dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. BL9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and Lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on BL9-3 is ideal for very dilute samples and single crystals. |
2014-09-30 12:14:21 |
Status Details |
open |
Open |
2014-09-30 12:14:16 |
Status |
operational |
Operational |
2014-02-21 06:22:41 |
Mirrors |
M0: Flat, bent, Rh-coated, Si; M1: Bent, cylindrical, Rh coated, Zerodur |
M0: Si, vertically collimating, Flat, Bent,1 m, Rh-coated; M1: Si, Bent, cylindrical, Rh coated, Zerodur |
2014-02-21 06:17:03 |
Lab Facilities |
Sample prep lab; coldroom |
Sample preparation laboratory, Cold room, glove boxes, microscopes |
2014-02-21 06:16:23 |
Cryo Capability Details |
|
5-200 K in cryostat, 20-200 K with cryostream |
2014-02-21 06:15:47 |
Cryo Capability |
LHe, continuous flow |
Oxford Liquid He cryostat and Oxford open flow liq He cryostream |
2014-02-21 06:14:48 |
Status Details |
|
open |
2014-02-21 06:14:40 |
Experiments |
EXAFS |
EXAFS |
2014-02-21 06:14:28 |
Detector: Model |
|
Canberra |
2014-02-21 06:14:11 |
Detector: Type |
30-element Ge solid state array; Lytle detector; ion chambers |
100 element Ge monolith detector, ion chambers, lytle and PIPS silicon drift detector. |
2014-02-21 06:13:30 |
Sample Handling: Robotics |
|
manual |
2014-02-21 06:13:14 |
Sample Handling: Manual |
|
typical : 18 mm Cu magnetic mounts, flexible mount environment |
2014-02-21 06:12:34 |
Goniometer |
|
Huber Kappa |
2014-02-21 06:11:52 |
Spot Size (mm): Height |
0.7 |
1 |
2014-02-21 06:11:41 |
Special Capabilities Details |
combined XRD and XAS on the same system. |
combined XRD and XAS on the same crystal system. |
2014-02-21 06:11:32 |
Special Capabilities Details |
|
combined XRD and XAS on the same system. |
2014-02-21 06:10:50 |
Source Type |
|
INSERTION DEVICE |
2014-02-21 06:10:29 |
Special Capabilities |
n/a |
Absorption Edges |
2014-02-21 06:10:07 |
Experiments Details |
|
Beamline 9-3 is a wiggler side-station beamline dedicated to biological X-ray absorption spectroscopy and EXAFS measurements of dilute solutions and single crystals. 9-3 is equipped with a 100-element Ge monolith solid-state detector in addition to ionization chambers and lytle detectors. A dedicated liq-He cryostat allows for routine low temperature measurements on solutions. A Huber-Kappa goniometer, a Liq-He cryostream, a focusing polycapillary and a MAR CCD detector are available (in addition to specialized software) for single crystal measurements. The higher flux, tighter focus and excellent beam stability on 9-3 is ideal for very dilute samples and single crystals. |
2014-02-21 06:09:26 |
Experiments |
XAS |
EXAFS |
2014-02-21 06:09:03 |
Secondary Contact: Email |
latimer@SLAC.Stanford.EDU |
latimer@slac.stanford.edu |
2014-02-21 06:08:52 |
Primary Contact: Name |
Serena DeBeer George |
Ritimukta Sarangi |
2014-02-21 06:08:45 |
Primary Contact: Email |
serena@slac.stanford.edu |
ritis@slac.stanford.edu |