Change history for SSRL - BL4-3

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2014-09-30 06:23:55 Cryo Capability Details 20-200 K
2014-09-30 06:23:46 Cryo Capability Cryo Industries Cryocool-LHe
2014-09-30 06:23:23 Cryo Capability Details 20-200 K
2014-09-30 06:23:17 Cryo Capability Cryo Industries Cryocool-LHe
2014-09-30 12:27:23 Software: Classification Control/collection, Processing Control/data collection, Processing, Analysis
2014-09-30 12:27:01 Lab Facilities COLD ROOM Sample preparation laboratory, cold room, glove boxes
2014-09-30 12:26:34 Cryo Capability Details 20-200 K
2014-09-30 12:26:22 Cryo Capability Oxford, open flow liq He cryostream
2014-09-30 12:25:33 Mirrors Vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff 4.5 to 14.5 keV Vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff variable 4.5 to 14.5 keV
2014-09-30 12:25:25 Mirrors vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff 4.5 to 14.5 keV Vertically collimating, flat, bent, 1.0 m, Si, Ni-coated, cutoff 4.5 to 14.5 keV
2014-09-30 12:25:12 Monochromator LN2 cooled, Si(111), phi = 0 & 90. double-crystal, non-fixed exit slit Liquid nitrogen-cooled double crystal, non-fixed exit slit.
2014-09-30 12:24:02 Secondary Contact: Email enelson@slac.stanford.edu
2014-09-30 12:23:46 Secondary Contact: Name Erik Nelson
2014-09-30 12:23:36 Status Details Open
2014-09-30 12:22:13 Experiments Details Beamline 4-3 is a wiggler side-station beamline dedicated for X-ray absorption spectroscopy and EXAFS measurements on biological and environmental systems. This station enables tender X-ray measurement (S K-edge and up) and is setup with a He flight path from the beamline optics to the sample. The beam is collimated and unfocused to allow for high energy-resolution measurements on homogenous samples. 4-3 is equipped with a four-element solid-state silicon drift detector in addition to ionization chambers and lytle detectors. A liquid He cryostream allows for low-temperature measurements. A motorized sample holder stage allows sequential measurement on multiple samples without sample changeover delays. Beam line 4-3 is a wiggler side-station beam line for X-ray absorption spectroscopy and EXAFS measurements. This station enables tender X-ray measurement (S K-edge and up) and is setup with a He flight path from the beam line optics to the sample. The beam is collimated and unfocused to allow for high energy-resolution measurements on homogenous samples. 4-3 is equipped with a 4-element solid-state Si drift detector in addition to ionization chambers, PIPS and Lytle detectors. A liquid He cryostream allows for low-temperature measurements. A motorized sample holder stage allows sequential measurement on multiple samples without sample changeover delays.
2014-09-25 07:14:46 Owner/Operator SSRL SSRL-SMB-XAS
2014-09-25 07:12:03 Cryo Capability Oxford Cryojet
2014-09-25 07:11:38 Cryo Capability Details Oxford one flow, liq He cryotream. Oxford open flow, liq He cryotream.
2014-09-25 07:11:30 Cryo Capability Details Oxford one flow, liq He cryotream.
2014-09-25 07:10:49 Cryo Capability Oxford Cryostream - 600 series
2014-09-25 07:10:27 Cryo Capability Oxford Cryostream - 600 series
2014-09-25 07:10:09 Detector: Type Ionization chambers, PIPS, Lytle, Hitachi HTA 4-element solid-state Si drift detector, electron-yield detector.
2014-09-25 07:09:44 Monochromator LN2 cooled, Si(111), Ï? = 0 & 90. double-crystal, non-fixed exit slit LN2 cooled, Si(111), phi = 0 & 90. double-crystal, non-fixed exit slit
2014-09-25 07:09:15 Experiments Details Beamline 4-3 is a wiggler side-station beamline dedicated for X-ray absorption spectroscopy and EXAFS measurements on biological and environmental systems. This station enables tender X-ray measurement (S K-edge and up) and is setup with a He flight path from the beamline optics to the sample. The beam is collimated and unfocused to allow for high energy-resolution measurements on homogenous samples. 4-3 is equipped with a four-element solid-state silicon drift detector in addition to ionization chambers and lytle detectors. A liquid He cryostream allows for low-temperature measurements. A motorized sample holder stage allows sequential measurement on multiple samples without sample changeover delays.