Change history for CHESS - F1

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2020-03-08 11:04:20 Status operational Decommissioned
2016-10-12 09:20:55 Robotics: More Info BAM-1, accepts MSC pucks, Unipucks, Rigaku pucks BAM-2, accepts MSC pucks, Unipucks, Rigaku pucks
2016-10-12 09:20:20 Detector: Removed from Service 2015-05-15
2016-10-12 09:15:24 Removed from Service: Details Replaced by Pilatus 6M, available as spare
2016-10-12 09:14:27 Spot Size (mm): Height 0.1 (collimator) or or 0.02 (focusing capillary) mm 0.1 (collimator) or 0.02 (focusing capillary) mm
2016-10-12 09:14:17 Spot Size (mm): Height 0.1 or 0.02 0.1 (collimator) or or 0.02 (focusing capillary) mm
2016-10-12 09:13:51 Spot Size (mm): Width Set by collimator (0.2 mm (vertical), 2.00 mm (horizontal)) 0.1 (collimator) or 0.02 (focusing capillary) mm
2016-10-12 09:13:01 Spot Size (mm): Height 0.2 0.1 or 0.02
2016-10-12 09:11:48 Energy Range (keV): Max 13.50 12.68
2016-10-12 09:10:50 Secondary Contact: Email djs63@cornell.edu dms35@cornell.edu
2016-10-12 09:10:39 Secondary Contact: Name David Schuller Marian Szebenyi
2016-10-12 09:10:24 Primary Contact: Email reg8@cornell.edu djs63@cornell.edu
2016-10-12 09:10:12 Primary Contact: Name Richard Gillilan David Schuller
2014-09-29 03:05:28 Software: Name HKL2000, DPS/Mosflm HKL2000, Mosflm, XDS
2014-09-29 03:05:02 Robotics: More Info If you wish to use the MacCHESS automounter, please specify this when you apply for beam time. BAM-1, accepts MSC pucks, Unipucks, Rigaku pucks
2014-09-29 03:04:25 Sample Handling: Robotics ALS style automounter ALS type automounter
2014-09-29 03:03:43 Energy Range (keV): Min 13.50 12.68
2014-09-29 03:03:33 Wavelength (Å): Max 0.918 0.98
2014-09-29 03:03:26 Wavelength (Å): Min 0.918 0.98
2014-09-29 03:02:59 Special Capabilities Absorption Edges BSL-2 biohazards accepted
2014-09-29 03:02:30 Special Capabilities xx Absorption Edges
2014-09-29 03:02:14 Special Capabilities Absorption Edges xx
2014-09-29 03:01:07 Special Capabilities Micro-diffraction Absorption Edges
2014-09-29 03:00:39 Special Capabilities Automatic Crystal Alignment, Micro-diffraction Micro-diffraction
2014-09-29 03:00:23 Experiments Details Suitable for Se SAD. Suitable for Se SAD
2014-09-29 03:00:14 Services Details Mail-in, remote data collection available
2014-09-29 02:59:50 Services High quality data collection, Mail-in, Rapid access High quality data collection
2014-09-29 02:59:22 Experiments Details Suitable for Br SAD. Suitable for Se SAD.
2011-05-19 08:40:15 Beamline Website http://www.macchess.cornell.edu/MacCHESS-2009/f1_summary.html http://www.chess.cornell.edu/chess/east/F1.htm
2009-08-24 04:31:16 Cryo Capability Oxford Cryosystems. The temperature is usually set to 100 K, but can be varied from 80 K to 400 K. Oxford Cryostream - 700 series
2009-08-24 04:30:33 Cryo Capability Details Programmable 80 to 400 K. Usually set to 100 K.
2009-08-10 03:00:03 Source Type bending magnet INSERTION DEVICE
2009-08-10 02:04:57 Detector: Activated for Service info currently not available 2007-03-01
2009-08-10 01:12:06 Backup Services Uers are welcome to bring their own laptop or other computers to CHESS for data processing and backup. IP addresses can be set up easily with DHCP, and static addresses are also available. MacCHESS Wired and wireless connections for user laptops. Ports for USB and FireWire external drives. SFTP to outside computers.
2009-08-10 01:09:41 Software: Name ADX package from ADSC for CCD and overall control; rspec and spec for other hardware control; http://www.macchess.cornell.edu/MacCHESS-2006/crystallography_software.html ADX package from ADSC for CCD and overall control; rspec and spec for other hardware control; http://www.macchess.cornell.edu/MacCHESS-2009/crystallography_software.html
2009-08-10 01:08:13 Detector: Model ADSC QUANTUM 210 ADSC Quantum 270
2009-08-10 01:05:13 Services High quality data collection, Mail-in, Rapid access
2009-08-10 01:04:32 Special Capabilities Automatic Crystal Alignment, Micro-diffraction
2009-08-10 01:02:42 Experiments Details Suitable for Br SAD.
2009-08-10 01:00:48 Experiments MONOCHROMATIC SAD, MONOCHROMATIC
2009-08-10 01:00:28 Beamline Website http://www.macchess.cornell.edu/MacCHESS-2006/f1_summary.html http://www.macchess.cornell.edu/MacCHESS-2009/f1_summary.html
2009-08-10 01:00:20 Primary Contact: Name Richard Gillian Richard Gillilan