2020-03-08 11:04:20 |
Status |
operational |
Decommissioned |
2016-10-12 09:20:55 |
Robotics: More Info |
BAM-1, accepts MSC pucks, Unipucks, Rigaku pucks |
BAM-2, accepts MSC pucks, Unipucks, Rigaku pucks |
2016-10-12 09:20:20 |
Detector: Removed from Service |
|
2015-05-15 |
2016-10-12 09:15:24 |
Removed from Service: Details |
|
Replaced by Pilatus 6M, available as spare |
2016-10-12 09:14:27 |
Spot Size (mm): Height |
0.1 (collimator) or or 0.02 (focusing capillary) mm |
0.1 (collimator) or 0.02 (focusing capillary) mm |
2016-10-12 09:14:17 |
Spot Size (mm): Height |
0.1 or 0.02 |
0.1 (collimator) or or 0.02 (focusing capillary) mm |
2016-10-12 09:13:51 |
Spot Size (mm): Width |
Set by collimator (0.2 mm (vertical), 2.00 mm (horizontal)) |
0.1 (collimator) or 0.02 (focusing capillary) mm |
2016-10-12 09:13:01 |
Spot Size (mm): Height |
0.2 |
0.1 or 0.02 |
2016-10-12 09:11:48 |
Energy Range (keV): Max |
13.50 |
12.68 |
2016-10-12 09:10:50 |
Secondary Contact: Email |
djs63@cornell.edu |
dms35@cornell.edu |
2016-10-12 09:10:39 |
Secondary Contact: Name |
David Schuller |
Marian Szebenyi |
2016-10-12 09:10:24 |
Primary Contact: Email |
reg8@cornell.edu |
djs63@cornell.edu |
2016-10-12 09:10:12 |
Primary Contact: Name |
Richard Gillilan |
David Schuller |
2014-09-29 03:05:28 |
Software: Name |
HKL2000, DPS/Mosflm |
HKL2000, Mosflm, XDS |
2014-09-29 03:05:02 |
Robotics: More Info |
If you wish to use the MacCHESS automounter, please specify this when you apply for beam time. |
BAM-1, accepts MSC pucks, Unipucks, Rigaku pucks |
2014-09-29 03:04:25 |
Sample Handling: Robotics |
ALS style automounter |
ALS type automounter |
2014-09-29 03:03:43 |
Energy Range (keV): Min |
13.50 |
12.68 |
2014-09-29 03:03:33 |
Wavelength (Å): Max |
0.918 |
0.98 |
2014-09-29 03:03:26 |
Wavelength (Å): Min |
0.918 |
0.98 |
2014-09-29 03:02:59 |
Special Capabilities |
Absorption Edges |
BSL-2 biohazards accepted |
2014-09-29 03:02:30 |
Special Capabilities |
xx |
Absorption Edges |
2014-09-29 03:02:14 |
Special Capabilities |
Absorption Edges |
xx |
2014-09-29 03:01:07 |
Special Capabilities |
Micro-diffraction |
Absorption Edges |
2014-09-29 03:00:39 |
Special Capabilities |
Automatic Crystal Alignment, Micro-diffraction |
Micro-diffraction |
2014-09-29 03:00:23 |
Experiments Details |
Suitable for Se SAD. |
Suitable for Se SAD |
2014-09-29 03:00:14 |
Services Details |
|
Mail-in, remote data collection available |
2014-09-29 02:59:50 |
Services |
High quality data collection, Mail-in, Rapid access |
High quality data collection |
2014-09-29 02:59:22 |
Experiments Details |
Suitable for Br SAD. |
Suitable for Se SAD. |
2011-05-19 08:40:15 |
Beamline Website |
http://www.macchess.cornell.edu/MacCHESS-2009/f1_summary.html |
http://www.chess.cornell.edu/chess/east/F1.htm |
2009-08-24 04:31:16 |
Cryo Capability |
Oxford Cryosystems. The temperature is usually set to 100 K, but can be varied from 80 K to 400 K. |
Oxford Cryostream - 700 series |
2009-08-24 04:30:33 |
Cryo Capability Details |
|
Programmable 80 to 400 K. Usually set to 100 K. |
2009-08-10 03:00:03 |
Source Type |
bending magnet |
INSERTION DEVICE |
2009-08-10 02:04:57 |
Detector: Activated for Service |
info currently not available |
2007-03-01 |
2009-08-10 01:12:06 |
Backup Services |
Uers are welcome to bring their own laptop or other computers to CHESS for data processing and backup. IP addresses can be set up easily with DHCP, and static addresses are also available. MacCHESS |
Wired and wireless connections for user laptops. Ports for USB and FireWire external drives. SFTP to outside computers. |
2009-08-10 01:09:41 |
Software: Name |
ADX package from ADSC for CCD and overall control; rspec and spec for other hardware control; http://www.macchess.cornell.edu/MacCHESS-2006/crystallography_software.html |
ADX package from ADSC for CCD and overall control; rspec and spec for other hardware control; http://www.macchess.cornell.edu/MacCHESS-2009/crystallography_software.html |
2009-08-10 01:08:13 |
Detector: Model |
ADSC QUANTUM 210 |
ADSC Quantum 270 |
2009-08-10 01:05:13 |
Services |
|
High quality data collection, Mail-in, Rapid access |
2009-08-10 01:04:32 |
Special Capabilities |
|
Automatic Crystal Alignment, Micro-diffraction |
2009-08-10 01:02:42 |
Experiments Details |
|
Suitable for Br SAD. |
2009-08-10 01:00:48 |
Experiments |
MONOCHROMATIC |
SAD, MONOCHROMATIC |
2009-08-10 01:00:28 |
Beamline Website |
http://www.macchess.cornell.edu/MacCHESS-2006/f1_summary.html |
http://www.macchess.cornell.edu/MacCHESS-2009/f1_summary.html |
2009-08-10 01:00:20 |
Primary Contact: Name |
Richard Gillian |
Richard Gillilan |