Change history for APS - 24-ID-E

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2025-03-31 11:54:28 Flux Coefficient 2.85 8.8
2025-03-31 11:54:20 Flux Exponent 12 13
2025-03-31 11:53:44 Crystal Type Si(220) or Si(311) Si(220)
2025-03-31 11:53:23 Optics Details Cryogenically-cooled single crystal Si(220) side bounce monochromator. Optional Si(311) to achive 13.474 keV. Cryogenically-cooled single crystal Si(220) side bounce monochromator.
2025-03-31 11:52:07 Special Capabilities Details Se-SAD data collection - Microbeams of size 5, 20, 50 and 100 microns are achived by use of beam shaping apertures. Microbeam - 5 microns at 1 sigma, 20 microns at 3 sigma, Dehydration - HC1 Humidity Control Device available, EDS - Silicon Drift Detector installed for energy dispersive X-ray analysis
2025-03-31 11:50:57 Special Capabilities Microdiffraction Microdiffraction, Room Temperature, Dehydration, EDS
2025-03-31 11:50:12 Experiments Details The beamline is optimized to address challenging cases in macromolecular crystallography such as large complex molecular assemblies, poorly diffracting crystals and microcrystals by providing extremely stable and intense x-ray beams with beam sizes ranging from 5 to 70 microns. The beamline is optimized to address challenging cases in macromolecular crystallography such as large complex molecular assemblies, poorly diffracting crystals and microcrystals by providing extremely stable and intense x-ray beams with beam sizes ranging from 5 to 20 microns.
2025-03-31 11:46:57 %Time Available (general use) 50 75
2025-03-31 11:46:32 Primary Contact: Name Raj Rajashankar Frank Murphy
2017-08-28 02:26:56 Detector: Model DECTRIS EIGER 16M DECTRIS EIGER 16M
2017-08-28 02:26:19 Detector: Model Other DECTRIS EIGER 16M
2017-08-28 02:25:30 Removed from Service: Details Replaced with Dectris Eiger 16M
2017-08-28 02:24:32 Detector: Removed from Service 2017-02-26
2014-09-30 02:17:41 Hardware Data storage composed of three NeXan SataBeasts and two HP EVA-5000 SAN. SAN is accessed via high performance GPFS file system which gives upto 5 times the performance of NFS. Data storage composed of three NeXan SataBeasts. SAN is accessed via high performance GPFS file system which gives upto 5 times the performance over NFS.
2014-09-30 02:11:41 Robotics: More Info Sample Magazine: 4 pucks, 16 samples/puck Automounter has a capacity of 14 pucks (ALS or unipuck)
2013-05-21 12:51:33 Hardware Data storage device is a HP EVA-5000 SAN. SAN is accessed via high performance GPFS file system which gives upto 5 times the performance of NFS. Data storage composed of three NeXan SataBeasts and two HP EVA-5000 SAN. SAN is accessed via high performance GPFS file system which gives upto 5 times the performance of NFS.
2013-05-21 12:50:09 Experiments Details The beamlines is optimized to address challenging cases in macromolecular crystallography such as large complex molecular assemblies, poorly diffracting crystals and microcrystals by providing extremely stable and intense x-ray beams with beam sizes ranging from 5 to 70 microns. The beamline is optimized to address challenging cases in macromolecular crystallography such as large complex molecular assemblies, poorly diffracting crystals and microcrystals by providing extremely stable and intense x-ray beams with beam sizes ranging from 5 to 70 microns.
2013-05-21 12:49:43 Secondary Contact: Email rajashankar@anl.gov capel@anl.gov
2013-05-21 12:49:37 Primary Contact: Email capel@anl.gov raja@anl.gov
2013-05-21 12:49:18 Secondary Contact: Name K. Rajashankar Malcom Capel
2013-05-21 12:49:09 Primary Contact: Name Malcom Capel Raj Rajashankar
2012-11-08 04:37:46 Flux Coefficient 1 2.85
2012-11-08 04:36:48 Flux Exponent 1213 12
2012-11-08 04:36:41 Flux Exponent 13 1213
2011-01-14 12:11:08 Crystal Type Si(111) or Si(311) Si(220) or Si(311)
2011-01-14 12:10:56 Optics Details Cryogenically-cooled single crystal Si(111) side bounce monochromator. Optional Si(311) to achive 13.474 keV. Cryogenically-cooled single crystal Si(220) side bounce monochromator. Optional Si(311) to achive 13.474 keV.
2011-01-14 12:10:25 Robotics: More Info Sample Magazine: 4 pucks, 16 samples/puck
2011-01-14 12:09:57 Sample Handling: Robotics ALS type automounter
2011-01-14 12:09:48 Goniometer Details MD2 Microdiffractometer (MK3 minikapp NOT available) MD2 Microdiffractometer (MK3 minikappa NOT available)
2011-01-14 12:09:41 Goniometer Details MD2 Microdiffractometer MD2 Microdiffractometer (MK3 minikapp NOT available)
2011-01-14 12:09:26 Goniometer Details MD2 Microdiffractometer MD2 Microdiffractometer
2011-01-14 12:09:22 Goniometer Huber 515 Maatel MD2
2011-01-14 12:09:06 Flux Exponent 12 13