2023-01-03 03:58:00 |
Sample Dehydration Prevention Method |
|
MiTeGen Watershed |
2023-01-03 03:57:49 |
Fixed Sample Motion Control Device |
|
in-house "tray goniometer" |
2023-01-03 03:57:35 |
Fixed Sample Target Details |
|
all SBS trays supported |
2023-01-03 03:57:11 |
Serial Crystallography Details |
|
user-provided LCP jet collection supported |
2023-01-03 03:56:00 |
Serial Crystallography Collimation/Focusing Optics |
|
parabola/torroid |
2023-01-03 03:54:46 |
Beam Focal Spot Size at Sample (µm^2) |
60 x 80 |
60 x 80 (h x v) |
2023-01-03 03:54:37 |
Beam Focal Spot Size at Sample (µm^2) |
|
60 x 80 |
2023-01-03 03:53:54 |
Cryo Capability Details |
user-controllable temperature up to ambient |
user-controllable temperature up to 45C |
2023-01-03 03:53:34 |
Detector: Details |
Pilatus3 S, 25Hz, S/N 60-0134 |
Pilatus3 S, 100Hz, S/N 60-0134 |
2023-01-03 03:53:10 |
Energy Range (keV): Max |
17 |
18 |
2023-01-03 03:52:50 |
Services Details |
|
all pin types supported |
2023-01-03 03:52:23 |
Owner/Operator |
University of California/Plexxikon Inc/Relay Therapeutics |
University of California San Francisco/Relay Therapeutics |
2023-01-03 03:52:05 |
Beamline Website |
tomalbertron.org |
https://tomalbertron.org |
2021-12-01 01:44:17 |
Hardware |
single server: 144 CPU, 1 TB RAM, 180 TB disk |
single server: 224 CPU, 3 TB RAM, 180 TB disk, 70s to process 3600 images |
2021-12-01 01:42:38 |
Source Type |
bending magnet |
BENDING MAGNET |
2021-12-01 01:42:23 |
Services |
|
unattended data collection |
2021-12-01 01:41:28 |
Beamline Website |
https://www-als.lbl.gov/index.php/ring-leaders/118-831.html |
tomalbertron.org |
2021-12-01 01:40:39 |
Owner/Operator |
University of California/Plexxikon Inc/MD Anderson Cancer Research Center |
University of California/Plexxikon Inc/Relay Therapeutics |
2016-08-23 06:29:41 |
Removed from Service: Details |
moved to ALS 12.3.1 |
detector moved to ALS 12.3.1 |
2016-08-23 06:25:37 |
Cryo Capability Details |
user-controllable temperature |
user-controllable temperature up to ambient |
2016-08-23 06:19:50 |
Detector: Details |
Pilatus3 S 25Hz |
Pilatus3 S 25Hz SN:60-0134 |
2016-08-23 06:14:37 |
Detector: Removed from Service |
2005-08-05 |
2001-08-05 |
2016-08-23 06:13:01 |
Software: Name |
CCP4, Mosflm, ELVES, XDS |
CCP4, Mosflm, ELVES, XDS, DIALS |
2016-08-23 06:10:32 |
Removed from Service: Details |
replaced with Pilatus3 S 6M |
|
2016-08-23 06:10:26 |
Removed from Service: Details |
replaced with Pilatus3 S 6M |
|
2016-08-23 06:10:19 |
Removed from Service: Details |
replaced with Pilatus3 S 6M |
|
2016-08-23 06:10:16 |
Removed from Service: Details |
replaced with Pilatus3 S 6M |
|
2016-08-23 06:09:58 |
Removed from Service: Details |
replaced with Pilatus3 S 6M |
|
2016-08-23 06:08:09 |
Backup Services |
Firewire/USB drives, automated DVD or Blu-Ray |
Firewire/USB3 drives, automated DVD or Blu-Ray |
2016-08-23 06:08:05 |
Hardware |
40 CPUs available |
single server: 144 CPU, 1 TB RAM, 180 TB disk |
2016-08-23 06:07:20 |
Detector: Model |
ADSC QUANTUM 315r |
ADSC Quantum 315r |
2016-08-23 06:07:08 |
Detector: Removed from Service |
|
2016-05-17 |
2016-08-23 06:06:53 |
Removed from Service: Details |
|
replaced with Pilatus3 S 6M |
2016-08-17 03:25:02 |
Beamline Website |
http://www.als.lbl.gov/als/techspecs/bl8.3.1.html |
https://www-als.lbl.gov/index.php/ring-leaders/118-831.html |
2016-01-22 03:01:37 |
Special Capabilities |
in-situ tray screening |
in-situ tray screening: all SBS formats supported |
2016-01-22 03:00:49 |
Experiments Details |
|
"true MAD" : inverse beam and round-robin wavelength changes every image |
2016-01-22 02:59:46 |
Backup Services |
Firewire drives, automated DVD |
Firewire/USB drives, automated DVD or Blu-Ray |
2016-01-22 02:58:45 |
Sample Handling: Manual |
|
All pin types supported: lengths 9 mm to 30 mm |
2016-01-22 02:58:15 |
Goniometer Details |
Air bearing for fast inverse beam measurements; fully user-changeable collimators |
Air bearing for fast inverse beam measurements; motorized collimators: 100, 75 50, 30 20 microns diameter |
2016-01-22 02:57:31 |
Goniometer |
Huber XYZ Stage |
Huber XYZ Stage ; 1.1 micron rms sphere of confusion |
2016-01-22 02:56:11 |
Optics Details |
|
water cooled |
2016-01-22 02:55:49 |
Source Details |
Superbend (5.0 tesla, single pole) |
Superbend (5.0 tesla, single dipole) |
2016-01-22 02:55:22 |
Owner/Operator |
University of California Berkeley/University of California San Francisco/Plexxikon Inc/MD Anderson Cancer Research Center/Alberta Synchrotron Institute |
University of California/Plexxikon Inc/MD Anderson Cancer Research Center |
2014-12-08 07:02:56 |
Software: Name |
CCP4, Mosflm, ELVES |
CCP4, Mosflm, ELVES, XDS |
2014-12-08 07:01:30 |
Flux Details |
Measured @ 2.0X0.3 milliradian divergence at 11111 eV with ALS at 500 mA and 1.9 GeV. |
Measured @ 3x0.35 milliradian divergence at 11111 eV with ALS at 500 mA and 1.9 GeV. |
2014-12-08 07:01:08 |
Flux Exponent |
11 |
12 |
2014-12-08 07:01:03 |
Flux Coefficient |
5.7 |
1.0 |
2014-12-08 07:00:43 |
Spot Size (mm): Width |
0.048 |
0.060 |
2014-12-08 07:00:38 |
Spot Size (mm): Height |
0.076 |
0.080 |
2014-12-08 07:00:00 |
Primary Contact: Email |
jmholton@lbl.gov |
JMHolton@lbl.gov |
2014-12-08 06:59:51 |
Secondary Contact: Email |
GMEigs@lbl.gov |
GMeigs@lbl.gov |
2014-12-08 06:59:45 |
Secondary Contact: Email |
|
GMEigs@lbl.gov |
2014-12-08 06:59:39 |
Secondary Contact: Name |
|
George Meigs |
2014-11-20 08:16:45 |
Spot Size (mm): Width |
0.06 |
0.048 |
2014-11-20 08:16:39 |
Spot Size (mm): Height |
0.14 |
0.076 |
2014-11-20 08:15:28 |
Flux Coefficient |
6 |
5.7 |
2014-11-20 08:12:56 |
Hardware |
16 Dual processor athlons |
40 CPUs available |
2014-11-20 08:09:23 |
Cryo Capability Details |
|
user-controllable temperature |
2014-11-20 08:07:43 |
Mirrors |
M1: plane parabola Pt and Rh-coated Si M2: torroid (2:1 demagnification) Pt and Rh-coated Si |
Pt and Rh-coated Si; M1: plane parabola M2: torroid (2:1 demagnification) |
2014-11-20 08:07:01 |
Flux Details |
Measured @ 3.0X0.3 milliradian divergence at 12660 eV with ALS at 400 mA and 1.9 GeV. |
Measured @ 2.0X0.3 milliradian divergence at 11111 eV with ALS at 500 mA and 1.9 GeV. |
2014-11-20 08:06:28 |
Flux Coefficient |
1.6 |
6 |
2014-11-20 08:06:01 |
Spot Size (mm): Width |
0.15 |
0.06 |
2014-11-20 08:05:40 |
Special Capabilities Details |
|
arrange in advance |
2014-11-20 08:05:14 |
Special Capabilities |
null |
in-situ tray screening |
2014-11-20 08:04:14 |
Beamline Website |
http://bcsb.lbl.gov/beam_feat.htm |
http://www.als.lbl.gov/als/techspecs/bl8.3.1.html |
2011-10-11 10:11:10 |
Robotics: More Info |
robot accepts all major pin types (Hampton, Yale, SPINE, etc.) and lengths (10-24 mm) and supports "delayed data collection mode" where data collection runs are deferred to the end of the shift. This robot does not work directly with cassettes because hand-mounting of samples in the mini-hutch is faster than any robot. |
Robot accepts all major pin types (Hampton, Yale, SPINE, etc.) and lengths (10-24 mm) and supports "delayed data collection mode" where data collection runs are deferred to the end of the shift. This robot does not work directly with cassettes because hand-mounting of samples in the mini-hutch is faster than any robot. |
2011-10-11 10:10:57 |
Robotics: More Info |
sample changing robot handles all pin types |
robot accepts all major pin types (Hampton, Yale, SPINE, etc.) and lengths (10-24 mm) and supports "delayed data collection mode" where data collection runs are deferred to the end of the shift. This robot does not work directly with cassettes because hand-mounting of samples in the mini-hutch is faster than any robot. |
2011-10-11 10:10:33 |
Sample Handling: Robotics |
|
Cool Hand Luke |